Qnect Logo

No Connections Report

Company: - Josh Qnect -
Job Title: - Qnect Demo 2000 Tons -
B+Op Status: B+Op was disabled for some sessions of this job
Building Code: AISC-14
Design Type: LRFD
Engineering Units: Imperial
Bolt Catalog: ASTM Imperial
Profile Catalog: ASTM Imperial
Plate Material Grade Catalog: ASTM Imperial
Plate Thickness Catalog: Imperial
Detailing Distances Dimensions: Imperial
Materials: 
Weld E70
Shear Plate A572-GR.50
Angle A36
Bm Web Doubler Plate A572-GR.50
Stabilizer Plate A572-GR.50
End Plate A572-GR.50
Col Moment Plate A572-GR.50
Col Stiffener Plate A572-GR.50
Col Web Doubler Plate A572-GR.50

Summary Reports: Job Standard Summary  |  Job Sample Calcs Report    |  B+Op Connection Comparison Report  |  Standard Connection Cost Report
Job Preferences Report  |  No Connections Summary  |  No Connections Detailed    |  No Connections Reference Map
 
Shear and Axial Reports:Shear Plate: Specs  Strengths (Shear Only Connections)  Welds  Doublers  Connection Cost Report
    Strengths (Shear & Axial Connections)      
 Single Angle:  Specs  Strengths (Shear & Axial)  Welds  Doublers  Connection Cost Report
 Double Angle Reports:  Support Side Specs  Strengths (Shear & Axial)  Welds  Doublers  Connection Cost Report
    Beam Side Specs        
 End Plate Reports:  Specs  Strengths (Shear & Axial)  Welds  Connection Cost Report
 
Moment Reports: Specs  Support Strengths  Beam Flange Welds  Connection Cost Report
 Moment Plates:  Specs  Strengths  Welds  
 Column Stiffeners:  Specs  Strengths  Welds  
 Column Web Doublers:  Specs  Strengths  Welds  
 Shear Plate:  Specs  Strengths  Welds  
 Double Angle:  Support Side Specs  Strengths  Welds  
   Beam Side Specs      
 

Identified Connections
Session Title Session Date Connection Status Support & Beam GUIDs Filler Beam Girder/Col Subgroup Type Connecting Area Perimeter Part Slope Skew Vertical Offset Horizontal Offset Span Vertical Shear Horizontal Shear Axial Compression Axial Tension DL Gravity Moment LL Gravity Moment Lateral Moment (major axis) Moment (minor axis) Torsion Work Point Z (Elevation) Support & Beam - Material (Original --> Alias)
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
0FF72920-63B7-425C-852D-3BDEA31FC591
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 72D20401-171A-43B4-9E85-FD7326EB793D
EE33A8A9-F537-4477-A5AC-D9BA95DC2936
W21X50 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) B0156EED-D6AB-4F84-AB7B-0764B23F4D1B
F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) DB752531-9B8F-4711-AC5E-48359335ED13
DB817010-7CEE-4081-A411-2FC4B4359D33
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 287D89E3-2910-4D30-87E6-F7D1BB3E3570
4309933C-0F6A-4286-B257-F2EB39DD3436
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 26078A27-21E9-4BCE-B431-7E227116B3C7
D36DDD80-E888-4513-9C2C-71A2BCBF06C4
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
D36DDD80-E888-4513-9C2C-71A2BCBF06C4
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
0FF72920-63B7-425C-852D-3BDEA31FC591
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) CB948ED9-E79D-4489-9D3F-ADB16F964EDF
BA96BAAC-587A-40CA-96A1-83669A105112
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) CB948ED9-E79D-4489-9D3F-ADB16F964EDF
EE33A8A9-F537-4477-A5AC-D9BA95DC2936
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) 23E85799-2C7A-460F-B3FF-71BDA721BD12
92EF3916-A56B-4A20-B442-20E8660C0053
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 23E85799-2C7A-460F-B3FF-71BDA721BD12
F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) 292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
96C37DAC-EA45-4337-B48E-42125BF0DC2B
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 0.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 0.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) 51D1F8E1-68FF-4440-A820-204EEDBA3418
92EF3916-A56B-4A20-B442-20E8660C0053
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 51D1F8E1-68FF-4440-A820-204EEDBA3418
E7C1653F-4913-4CE3-9EA0-69C7A8243EE6
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 90A462E5-CA35-4692-956F-4EE1F4BF5625
E7C1653F-4913-4CE3-9EA0-69C7A8243EE6
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 48F107CE-D352-4898-9BA4-C393926EB35A
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W21X93 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 40.95 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 2224E8EE-501A-41DC-8FD5-AC84DF83E654
7FBDC961-089E-40D5-B664-07F041D048B4
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 5.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 7FA570C6-DD9D-4B1A-BFA9-CA732829BB43
7FBDC961-089E-40D5-B664-07F041D048B4
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 5.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 63D31268-E3AA-4112-B508-49C2F4CF53AE
7FA570C6-DD9D-4B1A-BFA9-CA732829BB43
W16X31 W18X35 BEAM_TO_BEAM NONE 0 0.00 74.87 0.00 0.00 4.10 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) 9A2D54B0-BD9A-4CDC-8ECF-774527C0591D
BA96BAAC-587A-40CA-96A1-83669A105112
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 9A2D54B0-BD9A-4CDC-8ECF-774527C0591D
02A97F4B-88CD-49E2-B8F7-B601D15E2D75
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) 8613DBCA-0212-4BD1-AFD0-75420AF63377
C57FACC6-75E3-4B43-9496-4ABF8AC18722
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 40 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 8613DBCA-0212-4BD1-AFD0-75420AF63377
DB817010-7CEE-4081-A411-2FC4B4359D33
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) 26078A27-21E9-4BCE-B431-7E227116B3C7
4C29B3B1-C7F2-4501-95F5-E1CB28DDF6F0
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 -13.38 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 26078A27-21E9-4BCE-B431-7E227116B3C7
4309933C-0F6A-4286-B257-F2EB39DD3436
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 -13.38 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 1DD7A7F4-6903-451F-A300-0E9C6288A0D0
C2FE3DF9-1438-4898-BA0F-138446ED18C9
W21X50 W21X93 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 0.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) 96C37DAC-EA45-4337-B48E-42125BF0DC2B
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W18X35 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 24.05 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) 96C37DAC-EA45-4337-B48E-42125BF0DC2B
C2FE3DF9-1438-4898-BA0F-138446ED18C9
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 0.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
F0624484-6C43-4888-ADB3-F003191304E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Part of group with Not connected due to having Unsupported or Missing Force(s) D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
4C29B3B1-C7F2-4501-95F5-E1CB28DDF6F0
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
F0624484-6C43-4888-ADB3-F003191304E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:34:57 AM-OVERRIDE-1 2021-07-19 13:35:03 Not connected due to having Unsupported or Missing Force(s) ED91A022-0524-4EA7-BD72-56828A9D5708
02A97F4B-88CD-49E2-B8F7-B601D15E2D75
W21X50 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:20:12 AM-OVERRIDE-1 2021-07-19 13:20:33 Not connected due to having Unsupported or Missing Force(s) A927A1F9-8039-4BDC-9C79-62DC79580821
6627B2A8-9264-40F9-B2AC-A5B4F4177235
W14X22 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 10.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:20:12 AM-OVERRIDE-1 2021-07-19 13:20:33 Not connected due to having Unsupported or Missing Force(s) F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A
6627B2A8-9264-40F9-B2AC-A5B4F4177235
W14X22 W21X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 10.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:20:12 AM-OVERRIDE-1 2021-07-19 13:20:33 Part of group with Not connected due to having Unsupported or Missing Force(s) EA3CE990-278C-479E-8F99-638B208D2D8B
C57FACC6-75E3-4B43-9496-4ABF8AC18722
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_7/19/2021 10:20:12 AM-OVERRIDE-1 2021-07-19 13:20:33 Not connected due to having Unsupported or Missing Force(s) EA3CE990-278C-479E-8F99-638B208D2D8B
ECBE73FF-D014-44EA-9E19-DF8995CB03A1
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:51:20 PM-OVERRIDE-1 2021-05-24 15:51:25 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. 53D0FF22-5991-4FD0-B6D5-C082533FE4AE
1DD7A7F4-6903-451F-A300-0E9C6288A0D0
W21X93 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 15.00 60 0 0 0 0.00 0.00 300.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:51:20 PM-OVERRIDE-1 2021-05-24 15:51:25 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. EE1F12DF-FE3E-40BF-B26A-729650F69CFA
1DD7A7F4-6903-451F-A300-0E9C6288A0D0
W21X93 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 15.00 60 0 0 0 0.00 0.00 300.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:51:20 PM-OVERRIDE-1 2021-05-24 15:51:25 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. 2E83862E-26BB-4863-82F7-B01FB82A030C
48F107CE-D352-4898-9BA4-C393926EB35A
W21X93 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 60 0 0 0 0.00 0.00 300.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:51:20 PM-OVERRIDE-1 2021-05-24 15:51:25 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. 33A7A9DF-8934-400D-A85F-D3C12AA97266
48F107CE-D352-4898-9BA4-C393926EB35A
W21X93 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 60 0 0 0 0.00 0.00 300.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:13:19 PM 2021-05-24 15:13:20 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W18X35 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:12:08 PM 2021-05-24 15:12:09 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
5559C87D-459D-45B6-AC2B-8981D119187B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 50 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED5C2EB6-9AE4-4983-8ECB-7C2355014A79
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 -90.00 0.00 0.00 7.24 0 0 20 20 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 50 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
2825F4FF-8AD9-4C4C-9A27-05F28BD5EF57
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 50 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
AF583FEA-080E-4E48-9C79-C4365ECD85A9
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 90.00 0.00 0.00 7.24 0 0 20 20 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 50 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members F66924C0-E18D-4EC7-A4CB-9FD242C594E3
D5AA2C0E-5012-437D-995D-AA5C298A0936
HSS10X10X1/2 W14X257 VERTICAL_BRACING FLANGE 0 45.00 90.00 0.00 0.00 7.24 0 0 30 30 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members F66924C0-E18D-4EC7-A4CB-9FD242C594E3
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 MIDDLE_BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 50 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members F66924C0-E18D-4EC7-A4CB-9FD242C594E3
51D1F8E1-68FF-4440-A820-204EEDBA3418
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 50 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
6CB54B96-3712-4AAD-B36F-9E8ADA1D89AA
HSS10X10X1/2 W14X257 VERTICAL_BRACING FLANGE 0 45.00 -90.00 0.00 0.00 7.24 0 0 30 30 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 MIDDLE_BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 50 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 50 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 00828FF0-75D8-456C-A96A-BFD48AF22E23
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 50 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 00828FF0-75D8-456C-A96A-BFD48AF22E23
7EDF7D6C-BDB6-482E-A9C0-728CC22AD740
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 -90.00 0.00 0.00 7.24 0 0 20 20 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 00828FF0-75D8-456C-A96A-BFD48AF22E23
287D89E3-2910-4D30-87E6-F7D1BB3E3570
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 00828FF0-75D8-456C-A96A-BFD48AF22E23
72D20401-171A-43B4-9E85-FD7326EB793D
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 50 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 35A980C6-CADF-4D9F-A431-90FFC3463908
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 50 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 35A980C6-CADF-4D9F-A431-90FFC3463908
C6BF24A9-3B21-42D0-9CD3-2D717892A01A
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 90.00 0.00 0.00 7.24 0 0 20 20 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 35A980C6-CADF-4D9F-A431-90FFC3463908
F09CC89F-6963-48D4-A212-279378EB0D6B
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/24/2021 12:08:23 PM 2021-05-24 15:08:31 Grouping contains already connected members 35A980C6-CADF-4D9F-A431-90FFC3463908
72D20401-171A-43B4-9E85-FD7326EB793D
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 50 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 10:13:39 AM 2021-05-19 13:13:41 Filler beam workpoint is not between support end points. 51D1F8E1-68FF-4440-A820-204EEDBA3418
A8466654-5094-47CD-B66D-A1AAFA3F9B0B
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 10:13:39 AM 2021-05-19 13:13:41 Angle leg overhanging at support edge connection detail not supported yet. 16390BB9-5206-40BF-B328-6930C4D7F9D4
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W21X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
5559C87D-459D-45B6-AC2B-8981D119187B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED5C2EB6-9AE4-4983-8ECB-7C2355014A79
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 -90.00 0.00 0.00 7.24 0 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 80 0 20 20 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
2825F4FF-8AD9-4C4C-9A27-05F28BD5EF57
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
AF583FEA-080E-4E48-9C79-C4365ECD85A9
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 90.00 0.00 0.00 7.24 0 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 80 0 20 20 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
6580ED4C-F2AE-4AE8-878E-97DEF33B4D90
HSS10X10X1/2 W14X120 VERTICAL_BRACING WEB 0 45.00 -90.00 0.00 0.00 7.24 0 0 40 40 0.00 0.00 0.00 0 0 203.875 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W21X111 W14X120 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.86 80 0 20 20 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
8F17027E-EA70-4865-BE1A-22CE000E8C87
HSS10X10X1/2 W14X145 VERTICAL_BRACING WEB 0 45.00 90.00 0.00 0.00 7.24 0 0 40 40 0.00 0.00 0.00 0 0 202.125 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W21X111 W14X145 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.86 80 0 20 20 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
D5AA2C0E-5012-437D-995D-AA5C298A0936
HSS10X10X1/2 W14X257 VERTICAL_BRACING FLANGE 0 45.00 90.00 0.00 1.69 7.24 0 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 MIDDLE_BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 80 0 20 20 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
51D1F8E1-68FF-4440-A820-204EEDBA3418
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
6CB54B96-3712-4AAD-B36F-9E8ADA1D89AA
HSS10X10X1/2 W14X257 VERTICAL_BRACING FLANGE 0 45.00 -90.00 0.00 0.00 7.24 0 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 MIDDLE_BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 80 0 20 20 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:12:53 AM 2021-05-19 12:12:58 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
5559C87D-459D-45B6-AC2B-8981D119187B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED5C2EB6-9AE4-4983-8ECB-7C2355014A79
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 -90.00 0.00 0.00 7.24 80 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 80 0 40 40 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
2825F4FF-8AD9-4C4C-9A27-05F28BD5EF57
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
AF583FEA-080E-4E48-9C79-C4365ECD85A9
HSS10X10X1/2 W14X132 VERTICAL_BRACING WEB 0 45.00 90.00 0.00 0.00 7.24 80 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W21X111 W14X132 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 80 0 40 40 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
6580ED4C-F2AE-4AE8-878E-97DEF33B4D90
HSS10X10X1/2 W14X120 VERTICAL_BRACING WEB 0 45.00 -90.00 0.00 0.00 7.24 80 0 40 40 0.00 0.00 0.00 0 0 203.875 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W21X111 W14X120 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.86 80 0 40 40 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
8F17027E-EA70-4865-BE1A-22CE000E8C87
HSS10X10X1/2 W14X145 VERTICAL_BRACING WEB 0 45.00 90.00 0.00 0.00 7.24 80 0 40 40 0.00 0.00 0.00 0 0 202.125 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W21X111 W14X145 MIDDLE_BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.86 80 0 40 40 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
D5AA2C0E-5012-437D-995D-AA5C298A0936
HSS10X10X1/2 W14X257 VERTICAL_BRACING FLANGE 0 45.00 90.00 0.00 1.69 7.24 80 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 MIDDLE_BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 80 0 40 40 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
51D1F8E1-68FF-4440-A820-204EEDBA3418
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
6CB54B96-3712-4AAD-B36F-9E8ADA1D89AA
HSS10X10X1/2 W14X257 VERTICAL_BRACING FLANGE 0 45.00 -90.00 0.00 0.00 7.24 80 0 40 40 0.00 0.00 0.00 0 0 203 A992-->A992
A500-GR.B-->A500-GR.B
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 MIDDLE_BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 80 0 40 40 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 40 0 10 10 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/19/2021 9:02:26 AM 2021-05-19 12:02:31 Qnect does not support groups with multiple job preferences. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 4:23:34 PM 2021-05-05 19:25:21 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 4:01:54 PM 2021-05-05 19:01:58 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:47:08 PM 2021-05-05 18:47:19 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:47:08 PM 2021-05-05 18:47:19 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:47:08 PM 2021-05-05 18:47:19 Missing Top/Bottom Stabilizer Plates at one of opposite Shear Plate connections with Integrity Loads. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:47:08 PM 2021-05-05 18:47:19 Missing Top/Bottom Stabilizer Plates at one of opposite Shear Plate connections with Integrity Loads. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:47:08 PM 2021-05-05 18:47:19 Missing Top/Bottom Stabilizer Plates at one of opposite Shear Plate connections with Integrity Loads. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:47:08 PM 2021-05-05 18:47:19 Missing Top/Bottom Stabilizer Plates at one of opposite Shear Plate connections with Integrity Loads. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
5559C87D-459D-45B6-AC2B-8981D119187B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
2825F4FF-8AD9-4C4C-9A27-05F28BD5EF57
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:25:49 PM 2021-05-05 18:25:53 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W16X36 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
5559C87D-459D-45B6-AC2B-8981D119187B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
2825F4FF-8AD9-4C4C-9A27-05F28BD5EF57
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:16:39 PM 2021-05-05 18:16:54 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
5559C87D-459D-45B6-AC2B-8981D119187B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
2825F4FF-8AD9-4C4C-9A27-05F28BD5EF57
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_5/5/2021 3:14:28 PM 2021-05-05 18:14:32 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Grouping contains already connected members C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
ECBE73FF-D014-44EA-9E19-DF8995CB03A1
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Grouping contains already connected members 23E85799-2C7A-460F-B3FF-71BDA721BD12
92EF3916-A56B-4A20-B442-20E8660C0053
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Grouping contains already connected members 23E85799-2C7A-460F-B3FF-71BDA721BD12
F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Moments were turned off on the Minimum job Requirements page. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 40 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Moments were turned off on the Minimum job Requirements page. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Moments were turned off on the Minimum job Requirements page. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
51D1F8E1-68FF-4440-A820-204EEDBA3418
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
5559C87D-459D-45B6-AC2B-8981D119187B
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
2825F4FF-8AD9-4C4C-9A27-05F28BD5EF57
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Conflicting information in model. No Moment load provided, but Yes selected for moment connection. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Moments were turned off on the Minimum job Requirements page. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Moments were turned off on the Minimum job Requirements page. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 40 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 5:13:43 PM_DEMO 2021-04-14 20:13:55 Part of group with Moments were turned off on the Minimum job Requirements page. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:16:54 AM_DEMO 2021-04-14 14:16:57 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 15 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:16:54 AM_DEMO 2021-04-14 14:16:57 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 20 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:15:35 AM_DEMO 2021-04-14 14:15:37 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 20.7049 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:13:11 AM_DEMO 2021-04-14 14:13:15 Supported connection type not found F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:13:11 AM_DEMO 2021-04-14 14:13:15 Supported connection type not found FB940E28-44AA-4A35-836A-AD7ADF8E7F5D
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:13:11 AM_DEMO 2021-04-14 14:13:15 Supported connection type not found 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:13:11 AM_DEMO 2021-04-14 14:13:15 Supported connection type not found D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 20.7049 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 34.9472 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Moments were turned off on the Minimum job Requirements page. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Moments were turned off on the Minimum job Requirements page. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Moments were turned off on the Minimum job Requirements page. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
51D1F8E1-68FF-4440-A820-204EEDBA3418
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Supported connection type not found 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Supported connection type not found 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Supported connection type not found AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Supported connection type not found AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Supported connection type not found AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Supported connection type not found AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Supported connection type not found D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Supported connection type not found D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Moments were turned off on the Minimum job Requirements page. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Moments were turned off on the Minimum job Requirements page. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Part of group with Moments were turned off on the Minimum job Requirements page. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Supported connection type not found FB940E28-44AA-4A35-836A-AD7ADF8E7F5D
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_4/14/2021 11:06:55 AM_DEMO 2021-04-14 14:07:11 Supported connection type not found 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:07:22 AM-OVERRIDE-1 2021-03-11 14:07:30 Part of group with Not connected due to having Unsupported or Missing Force(s) 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
A927A1F9-8039-4BDC-9C79-62DC79580821
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:07:22 AM-OVERRIDE-1 2021-03-11 14:07:30 Not connected due to having Unsupported or Missing Force(s) 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 0 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Double Angles Bolted Welded are not supported at Beam to Beam framing condition 26078A27-21E9-4BCE-B431-7E227116B3C7
D36DDD80-E888-4513-9C2C-71A2BCBF06C4
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Not connected due to gage or angle size issue. 7FA570C6-DD9D-4B1A-BFA9-CA732829BB43
7FBDC961-089E-40D5-B664-07F041D048B4
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 5.00 35 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 20.7049 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 34.9472 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
96C37DAC-EA45-4337-B48E-42125BF0DC2B
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Angle leg overhanging at support edge connection detail not supported yet. 2224E8EE-501A-41DC-8FD5-AC84DF83E654
7FBDC961-089E-40D5-B664-07F041D048B4
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 5.00 35 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
51D1F8E1-68FF-4440-A820-204EEDBA3418
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Supported connection type not found 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Supported connection type not found 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Supported connection type not found AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Supported connection type not found AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Supported connection type not found AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Supported connection type not found AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Supported connection type not found D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Supported connection type not found D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-386 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
A927A1F9-8039-4BDC-9C79-62DC79580821
W21X111 W14X257 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 90.00 8.75 0.00 25.00 167.4 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 -90.00 8.75 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 1367920D-1AB5-4383-A2AF-6B6E618C214F
A927A1F9-8039-4BDC-9C79-62DC79580821
W21X111 W14X257 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 -90.00 8.75 0.00 25.00 167.4 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 1367920D-1AB5-4383-A2AF-6B6E618C214F
B0156EED-D6AB-4F84-AB7B-0764B23F4D1B
W18X40 W14X257 BEAM_TO_COLUMN WEB_TOP 0 0.00 90.00 8.75 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
3/11/2021 11:03:15 AM 2021-03-11 14:03:29 Supported connection type not found FB940E28-44AA-4A35-836A-AD7ADF8E7F5D
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/17/2021 10:02:31 AM 2021-02-17 13:02:38 Supported connection type not found F139CD10-81FD-4BFE-AA25-1701E83B9DC3
EA477146-1593-48C2-8235-F6740BB0F1BF
W18X35 W14X370 BEAM_TO_COLUMN WEB_TOP 0 0.00 70.37 0.00 0.00 44.84 163.301 0 0 0 0.00 0.00 0.00 0 0 1048.5 A992-->A992
A992-->A992
JTH_2/12/2021 12:51:36 PM_NEW_FUNC 2021-02-12 15:51:37 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 08A78FF9-FFE7-465E-89B4-0099A228D37F
69A52778-3FD9-4842-9109-5C54E3C5F544
W16X40 W18X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 2.00 40 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 12:50:52 PM_NEW_FUNC 2021-02-12 15:50:52 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 08A78FF9-FFE7-465E-89B4-0099A228D37F
69A52778-3FD9-4842-9109-5C54E3C5F544
W16X67 W18X86 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 2.00 40 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 12:49:43 PM_NEW_FUNC 2021-02-12 15:49:45 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 08A78FF9-FFE7-465E-89B4-0099A228D37F
69A52778-3FD9-4842-9109-5C54E3C5F544
W16X67 W18X86 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 2.00 68 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 12:47:23 PM_NEW_FUNC 2021-02-12 15:47:24 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 08A78FF9-FFE7-465E-89B4-0099A228D37F
69A52778-3FD9-4842-9109-5C54E3C5F544
W16X40 W18X60 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 2.00 68 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 12:45:23 PM_NEW_FUNC 2021-02-12 15:45:24 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 08A78FF9-FFE7-465E-89B4-0099A228D37F
69A52778-3FD9-4842-9109-5C54E3C5F544
W16X40 W18X97 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 2.00 68 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 12:23:35 PM_NEW_FUNC 2021-02-12 15:23:36 Grouping contains already connected members 6F5FE9D8-DFD2-4B2D-B45B-A08C8EFB663E
E9158D70-B0A8-45CB-9E0F-E688506391E1
W16X40 W18X50 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 2.00 2 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 12:22:44 PM_NEW_FUNC 2021-02-12 15:22:45 Grouping contains already connected members 6F5FE9D8-DFD2-4B2D-B45B-A08C8EFB663E
E9158D70-B0A8-45CB-9E0F-E688506391E1
W16X40 W18X50 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 2.00 2 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 10:37:45 AM_NEW_FUNC 2021-02-12 13:37:46 Not connected due to user preference. EEE2AA7F-FC77-4FE4-96B5-D02D74BAC425
BDD18371-07DF-41E5-A71B-155C860FC735
W16X40 W18X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 2.00 30 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_2/12/2021 8:09:56 AM 2021-02-12 11:10:00 Grouping contains already connected members C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
B0156EED-D6AB-4F84-AB7B-0764B23F4D1B
W18X40 W18X40 BEAM_SPLICE NONE 1 0.00 0.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:09:56 AM 2021-02-12 11:10:00 Grouping contains already connected members E2D175EF-339B-4EDC-816D-836B20EFFFAE
48F107CE-D352-4898-9BA4-C393926EB35A
W18X40 W18X40 BEAM_SPLICE NONE 1 0.00 0.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:05:08 AM 2021-02-12 11:06:20 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 206CA453-13D3-418A-AA3D-3C86589ECF9C
EE33A8A9-F537-4477-A5AC-D9BA95DC2936
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:05:08 AM 2021-02-12 11:06:20 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. B0156EED-D6AB-4F84-AB7B-0764B23F4D1B
F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:05:08 AM 2021-02-12 11:06:20 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. E2D175EF-339B-4EDC-816D-836B20EFFFAE
4309933C-0F6A-4286-B257-F2EB39DD3436
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:05:08 AM 2021-02-12 11:06:20 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
ECBE73FF-D014-44EA-9E19-DF8995CB03A1
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:05:08 AM 2021-02-12 11:06:20 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 48F107CE-D352-4898-9BA4-C393926EB35A
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 40.95 34.9472 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:05:08 AM 2021-02-12 11:06:20 Grouping contains already connected members C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
B0156EED-D6AB-4F84-AB7B-0764B23F4D1B
W18X40 W18X40 BEAM_SPLICE NONE 1 0.00 0.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 8:05:08 AM 2021-02-12 11:06:20 Grouping contains already connected members E2D175EF-339B-4EDC-816D-836B20EFFFAE
48F107CE-D352-4898-9BA4-C393926EB35A
W18X40 W18X40 BEAM_SPLICE NONE 1 0.00 0.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. DB752531-9B8F-4711-AC5E-48359335ED13
DB817010-7CEE-4081-A411-2FC4B4359D33
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. CB948ED9-E79D-4489-9D3F-ADB16F964EDF
BA96BAAC-587A-40CA-96A1-83669A105112
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. CB948ED9-E79D-4489-9D3F-ADB16F964EDF
EE33A8A9-F537-4477-A5AC-D9BA95DC2936
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 23E85799-2C7A-460F-B3FF-71BDA721BD12
92EF3916-A56B-4A20-B442-20E8660C0053
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 23E85799-2C7A-460F-B3FF-71BDA721BD12
F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 51D1F8E1-68FF-4440-A820-204EEDBA3418
92EF3916-A56B-4A20-B442-20E8660C0053
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 51D1F8E1-68FF-4440-A820-204EEDBA3418
E7C1653F-4913-4CE3-9EA0-69C7A8243EE6
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 90A462E5-CA35-4692-956F-4EE1F4BF5625
E7C1653F-4913-4CE3-9EA0-69C7A8243EE6
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle leg overhanging at support edge connection detail not supported yet. 2224E8EE-501A-41DC-8FD5-AC84DF83E654
7FBDC961-089E-40D5-B664-07F041D048B4
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 5.00 35 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Not connected due to gage or angle size issue. 7FA570C6-DD9D-4B1A-BFA9-CA732829BB43
7FBDC961-089E-40D5-B664-07F041D048B4
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 5.00 35 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 9A2D54B0-BD9A-4CDC-8ECF-774527C0591D
BA96BAAC-587A-40CA-96A1-83669A105112
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 9A2D54B0-BD9A-4CDC-8ECF-774527C0591D
02A97F4B-88CD-49E2-B8F7-B601D15E2D75
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. ED91A022-0524-4EA7-BD72-56828A9D5708
02A97F4B-88CD-49E2-B8F7-B601D15E2D75
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
F0624484-6C43-4888-ADB3-F003191304E8
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 1DD7A7F4-6903-451F-A300-0E9C6288A0D0
C2FE3DF9-1438-4898-BA0F-138446ED18C9
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
96C37DAC-EA45-4337-B48E-42125BF0DC2B
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
0FF72920-63B7-425C-852D-3BDEA31FC591
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
D36DDD80-E888-4513-9C2C-71A2BCBF06C4
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
0FF72920-63B7-425C-852D-3BDEA31FC591
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 8613DBCA-0212-4BD1-AFD0-75420AF63377
C57FACC6-75E3-4B43-9496-4ABF8AC18722
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 8613DBCA-0212-4BD1-AFD0-75420AF63377
DB817010-7CEE-4081-A411-2FC4B4359D33
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. EA3CE990-278C-479E-8F99-638B208D2D8B
C57FACC6-75E3-4B43-9496-4ABF8AC18722
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. EA3CE990-278C-479E-8F99-638B208D2D8B
ECBE73FF-D014-44EA-9E19-DF8995CB03A1
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
4C29B3B1-C7F2-4501-95F5-E1CB28DDF6F0
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. D1A6C82C-8AB1-493D-82F7-CE24FB1F9DE0
F0624484-6C43-4888-ADB3-F003191304E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 26078A27-21E9-4BCE-B431-7E227116B3C7
4C29B3B1-C7F2-4501-95F5-E1CB28DDF6F0
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 -13.38 20.00 18.525 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 26078A27-21E9-4BCE-B431-7E227116B3C7
4309933C-0F6A-4286-B257-F2EB39DD3436
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 -13.38 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 96C37DAC-EA45-4337-B48E-42125BF0DC2B
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 24.05 20.7049 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Angle Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 96C37DAC-EA45-4337-B48E-42125BF0DC2B
C2FE3DF9-1438-4898-BA0F-138446ED18C9
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36.6667 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 20.7049 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 34.9472 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. F66924C0-E18D-4EC7-A4CB-9FD242C594E3
51D1F8E1-68FF-4440-A820-204EEDBA3418
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 59.2786 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Supported connection type not found 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
F0A0D58D-A226-493C-A5C8-446DEFDD4CD3
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Supported connection type not found 5868913B-BDBA-4E5A-B5D6-48B26974F6A1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Supported connection type not found AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
ED91A022-0524-4EA7-BD72-56828A9D5708
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.00 61.8947 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Supported connection type not found AA1EA23A-90C4-4D3C-8706-38E2BCE788C1
DB752531-9B8F-4711-AC5E-48359335ED13
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Supported connection type not found AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 59.0152 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Supported connection type not found AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Supported connection type not found D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 59.2319 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Supported connection type not found D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 62.3563 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 998074A7-8FD9-4EE9-B334-F86718247B9F
292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
W21X111 W14X159 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 32.48 128.852 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 18.58 225.202 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 58.8 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. FB940E28-44AA-4A35-836A-AD7ADF8E7F5D
8BF79663-F91D-43BA-BC79-996B828F04B9
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.00 167.4 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. FB940E28-44AA-4A35-836A-AD7ADF8E7F5D
CC5F9CF6-449D-4C35-8B9E-622A6077C613
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 47A67565-B8C2-420B-BE06-0654754D5B64
292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
W21X111 W14X176 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 32.48 128.852 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. B47A768D-5540-4656-B43C-8046E618DEED
E5D5964A-3719-4D43-B300-05F21CD4859B
W21X101 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 130.862 0 0 0 0.00 0.00 0.00 0 0 214.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. E1C83365-3B55-4495-9182-2C1E9D4EE520
E5D5964A-3719-4D43-B300-05F21CD4859B
W21X101 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 130.862 0 0 0 0.00 0.00 0.00 0 0 214.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
A927A1F9-8039-4BDC-9C79-62DC79580821
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 167.4 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 209.25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 1367920D-1AB5-4383-A2AF-6B6E618C214F
A927A1F9-8039-4BDC-9C79-62DC79580821
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.00 167.4 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/12/2021 7:52:43 AM 2021-02-12 10:53:43 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 26BF8091-52CE-4FBA-A989-BD46FDEDDEDF
8BF79663-F91D-43BA-BC79-996B828F04B9
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 167.4 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A for component: 51982650 was already connected. 23E85799-2C7A-460F-B3FF-71BDA721BD12
92EF3916-A56B-4A20-B442-20E8660C0053
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 17 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A for component: 51982650 was already connected. 23E85799-2C7A-460F-B3FF-71BDA721BD12
F05F6CC0-80A1-4A7E-B569-A3BD9D2A148A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: EE33A8A9-F537-4477-A5AC-D9BA95DC2936 for component: 51982648 was already connected. CB948ED9-E79D-4489-9D3F-ADB16F964EDF
BA96BAAC-587A-40CA-96A1-83669A105112
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 17 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: EE33A8A9-F537-4477-A5AC-D9BA95DC2936 for component: 51982648 was already connected. CB948ED9-E79D-4489-9D3F-ADB16F964EDF
EE33A8A9-F537-4477-A5AC-D9BA95DC2936
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: ECBE73FF-D014-44EA-9E19-DF8995CB03A1 for component: 51982646 was already connected. EA3CE990-278C-479E-8F99-638B208D2D8B
C57FACC6-75E3-4B43-9496-4ABF8AC18722
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 17 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: ECBE73FF-D014-44EA-9E19-DF8995CB03A1 for component: 51982646 was already connected. EA3CE990-278C-479E-8F99-638B208D2D8B
ECBE73FF-D014-44EA-9E19-DF8995CB03A1
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 4C29B3B1-C7F2-4501-95F5-E1CB28DDF6F0 for component: 51982645 was already connected. 26078A27-21E9-4BCE-B431-7E227116B3C7
4C29B3B1-C7F2-4501-95F5-E1CB28DDF6F0
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 -13.38 20.00 17 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 4309933C-0F6A-4286-B257-F2EB39DD3436 for component: 51982644 was already connected. 26078A27-21E9-4BCE-B431-7E227116B3C7
4309933C-0F6A-4286-B257-F2EB39DD3436
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 -13.38 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
BB25F9ED-F9E1-4A1E-A064-0C5CCF608FED
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Part of group with Member rotation and/or slope combination not yet supported by Qnect. FBEC2BBC-F742-4700-96FA-3C530C168AC3
AA2F8277-06BB-4D37-BF17-6734EE254C7D
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 7DBF7F1C-DA2D-4C82-A87D-A14B75A4239A for component: 51982641 was already connected. 33A7A9DF-8934-400D-A85F-D3C12AA97266
7DBF7F1C-DA2D-4C82-A87D-A14B75A4239A
W18X40 W14X99 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 36.90 23 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 48F107CE-D352-4898-9BA4-C393926EB35A for component: 51982640 was already connected. 33A7A9DF-8934-400D-A85F-D3C12AA97266
48F107CE-D352-4898-9BA4-C393926EB35A
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 28 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: B2CC3007-3BA8-4151-83BA-E6C647610CDD for component: 51982639 was already connected. 53D59C92-98B5-4DAB-BA5F-50492C96C284
B2CC3007-3BA8-4151-83BA-E6C647610CDD
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 16.60 13 0 0 0 0.00 0.00 0.00 0 0 214.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 7DBF7F1C-DA2D-4C82-A87D-A14B75A4239A for component: 51982638 was already connected. 53D59C92-98B5-4DAB-BA5F-50492C96C284
7DBF7F1C-DA2D-4C82-A87D-A14B75A4239A
W18X40 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 36.90 23 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: FBEC2BBC-F742-4700-96FA-3C530C168AC3 for component: 51982637 was already connected. 53D59C92-98B5-4DAB-BA5F-50492C96C284
FBEC2BBC-F742-4700-96FA-3C530C168AC3
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E for component: 51982636 was already connected. AA26CAD0-73EC-424F-ABB4-C4970AED2987
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: E2D175EF-339B-4EDC-816D-836B20EFFFAE for component: 51982635 was already connected. AA26CAD0-73EC-424F-ABB4-C4970AED2987
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.93 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 206CA453-13D3-418A-AA3D-3C86589ECF9C for component: 51982634 was already connected. AA26CAD0-73EC-424F-ABB4-C4970AED2987
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 18.86 30 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 9632746D-EC11-493F-AD5F-27C9FDAC4704 for component: 51982633 was already connected. FA8BF116-607D-4A44-8F41-85ACEEC6CE5F
9632746D-EC11-493F-AD5F-27C9FDAC4704
W12X19 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 17 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E for component: 51982632 was already connected. FA8BF116-607D-4A44-8F41-85ACEEC6CE5F
0D8CCBBF-1B62-40C9-BDFA-92B48DF15D1E
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 26078A27-21E9-4BCE-B431-7E227116B3C7 for component: 51982631 was already connected. FA8BF116-607D-4A44-8F41-85ACEEC6CE5F
26078A27-21E9-4BCE-B431-7E227116B3C7
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: CB948ED9-E79D-4489-9D3F-ADB16F964EDF for component: 51982630 was already connected. FA8BF116-607D-4A44-8F41-85ACEEC6CE5F
CB948ED9-E79D-4489-9D3F-ADB16F964EDF
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Grouping contains already connected members 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
A927A1F9-8039-4BDC-9C79-62DC79580821
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Grouping contains already connected members 6C2FCDAD-45EE-46D3-A98A-6043DB59C9EA
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Grouping contains already connected members 1367920D-1AB5-4383-A2AF-6B6E618C214F
A927A1F9-8039-4BDC-9C79-62DC79580821
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.00 167.4 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Grouping contains already connected members 1367920D-1AB5-4383-A2AF-6B6E618C214F
B0156EED-D6AB-4F84-AB7B-0764B23F4D1B
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 16390BB9-5206-40BF-B328-6930C4D7F9D4 for component: 51982625 was already connected. 0BE5EED8-2AF7-48CF-A687-9A8AC551FF71
16390BB9-5206-40BF-B328-6930C4D7F9D4
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2 for component: 51982624 was already connected. 0BE5EED8-2AF7-48CF-A687-9A8AC551FF71
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.85 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: B0156EED-D6AB-4F84-AB7B-0764B23F4D1B for component: 51982623 was already connected. 0BE5EED8-2AF7-48CF-A687-9A8AC551FF71
B0156EED-D6AB-4F84-AB7B-0764B23F4D1B
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.84 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
79759B65-6264-49A8-8CC3-701F6FBE9D63
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 18.58 25 0 0 0 0.00 0.00 180.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
E64804C2-CE3F-4FD8-A2C1-DBD5FFBBEDDB
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Part of group with Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D3DC0A75-7E7E-40C0-B701-0DB18377EDE2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 67DD4C1B-1DF7-4E8C-BCB4-48CCAFBE6D21 for component: 51982619 was already connected. 744C49F0-9C30-489E-9A24-B7CF0FBE30F2
67DD4C1B-1DF7-4E8C-BCB4-48CCAFBE6D21
W12X19 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 17 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 16390BB9-5206-40BF-B328-6930C4D7F9D4 for component: 51982618 was already connected. 744C49F0-9C30-489E-9A24-B7CF0FBE30F2
16390BB9-5206-40BF-B328-6930C4D7F9D4
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: EA3CE990-278C-479E-8F99-638B208D2D8B for component: 51982617 was already connected. 744C49F0-9C30-489E-9A24-B7CF0FBE30F2
EA3CE990-278C-479E-8F99-638B208D2D8B
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 23E85799-2C7A-460F-B3FF-71BDA721BD12 for component: 51982616 was already connected. 744C49F0-9C30-489E-9A24-B7CF0FBE30F2
23E85799-2C7A-460F-B3FF-71BDA721BD12
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 435CC532-A59F-4D55-8AC1-27AD9EC08AF6 for component: 51982615 was already connected. 2E83862E-26BB-4863-82F7-B01FB82A030C
435CC532-A59F-4D55-8AC1-27AD9EC08AF6
W21X50 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 32 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: E2D175EF-339B-4EDC-816D-836B20EFFFAE for component: 51982614 was already connected. 2E83862E-26BB-4863-82F7-B01FB82A030C
E2D175EF-339B-4EDC-816D-836B20EFFFAE
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.93 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 48F107CE-D352-4898-9BA4-C393926EB35A for component: 51982613 was already connected. 2E83862E-26BB-4863-82F7-B01FB82A030C
48F107CE-D352-4898-9BA4-C393926EB35A
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 29 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 292EB47E-CDD6-48BF-B6BD-5FA10F710D6D for component: 51982612 was already connected. 998074A7-8FD9-4EE9-B334-F86718247B9F
292EB47E-CDD6-48BF-B6BD-5FA10F710D6D
W21X111 W14X159 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 32.48 49 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 435CC532-A59F-4D55-8AC1-27AD9EC08AF6 for component: 51982611 was already connected. 998074A7-8FD9-4EE9-B334-F86718247B9F
435CC532-A59F-4D55-8AC1-27AD9EC08AF6
W21X50 W14X159 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 26078A27-21E9-4BCE-B431-7E227116B3C7 for component: 51982610 was already connected. 998074A7-8FD9-4EE9-B334-F86718247B9F
26078A27-21E9-4BCE-B431-7E227116B3C7
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: FBEC2BBC-F742-4700-96FA-3C530C168AC3 for component: 51982609 was already connected. 998074A7-8FD9-4EE9-B334-F86718247B9F
FBEC2BBC-F742-4700-96FA-3C530C168AC3
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B for component: 51982608 was already connected. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2 for component: 51982607 was already connected. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
C2D7323C-E6FA-4BD4-84FF-F102EE99D8D2
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.85 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 206CA453-13D3-418A-AA3D-3C86589ECF9C for component: 51982606 was already connected. D3FA45C0-16E1-44CB-BB01-D0EF79D1A489
206CA453-13D3-418A-AA3D-3C86589ECF9C
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 18.86 30 0 15 15 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 6600803A-D2BC-4EF3-9A43-3CFBDC96506B for component: 51982605 was already connected. 2B723011-7991-4B75-8F41-E91C0542A2A2
6600803A-D2BC-4EF3-9A43-3CFBDC96506B
W12X19 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 17 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: 2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B for component: 51982604 was already connected. 2B723011-7991-4B75-8F41-E91C0542A2A2
2EE70011-13DF-4B7D-A6DC-AF64D3ACC43B
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: EA3CE990-278C-479E-8F99-638B208D2D8B for component: 51982603 was already connected. 2B723011-7991-4B75-8F41-E91C0542A2A2
EA3CE990-278C-479E-8F99-638B208D2D8B
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 10:19:30 AM 2021-02-11 13:19:40 Secondary: CB948ED9-E79D-4489-9D3F-ADB16F964EDF for component: 51982602 was already connected. 2B723011-7991-4B75-8F41-E91C0542A2A2
CB948ED9-E79D-4489-9D3F-ADB16F964EDF
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_2/11/2021 9:56:48 AM_ExportImport 2021-02-11 12:56:52 The GUID of the secondary beam (9A3DED1D-E013-4767-9AB1-866C01462491) for component 51982599 was not valid. 7C94114F-5491-41B9-AAE0-72BC8B0775DD
9A3DED1D-E013-4767-9AB1-866C01462491
W16X40 W16X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 20.00 20 0 0 0 0.00 0.00 0.00 0 0 0 A992-->A992
A992-->A992
JTH_1/28/2021 8:39:37 AM 2021-01-28 11:39:45 Connection Type preference is not supported. 0C361245-4469-472F-B53F-0EA61D17AF18
324DBC2D-0539-4DD3-8E25-F36BB1C249C3
W21X68 W12X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 10 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_1/28/2021 8:38:17 AM 2021-01-28 11:38:20 Connection Type preference is not supported. 0C361245-4469-472F-B53F-0EA61D17AF18
324DBC2D-0539-4DD3-8E25-F36BB1C249C3
W21X68 W12X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 213.75 A992-->A992
A992-->A992
JTH_1/27/2021 9:53:55 AM 2021-01-27 12:53:58 Not connected due to gage or angle size issue. D12D83FC-502D-4F2F-B8AA-7FC5D0B6FFA4
9C3D5A40-7664-4DC4-98C3-3943A25F7385
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 17 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_1/27/2021 9:53:55 AM 2021-01-27 12:53:58 Part of group with Not connected due to gage or angle size issue. D12D83FC-502D-4F2F-B8AA-7FC5D0B6FFA4
B7E4041B-41D7-4398-9D40-36F4A4A7016F
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_1/27/2021 9:30:28 AM 2021-01-27 12:30:45 Unsupported connection data at opposite connections with shared bolts. 90686697-E1FE-4886-8998-19A5F135BE4B
09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
JTH_1/27/2021 9:30:28 AM 2021-01-27 12:30:45 Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_1/27/2021 9:30:28 AM 2021-01-27 12:30:45 Part of group with Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
45BC41E9-CD90-4FFA-B42C-23D3957752FE
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_1/27/2021 9:30:28 AM 2021-01-27 12:30:45 Unsupported connection data at opposite connections with shared bolts. D731B8AB-F16E-4E58-8CF8-9D461F1801BF
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 24.05 19 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_1/27/2021 9:30:28 AM 2021-01-27 12:30:45 Unsupported connection data at opposite connections with shared bolts. D731B8AB-F16E-4E58-8CF8-9D461F1801BF
67BFA688-A1F6-415F-BCF0-F7362C79DD89
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_1/27/2021 9:30:28 AM 2021-01-27 12:30:45 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
JTH_1/27/2021 9:30:28 AM 2021-01-27 12:30:45 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
JTH_12/15/2020 2:35:12 PM 2020-12-15 17:35:21 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. 1A6B8184-4FA3-410F-8907-F491B11C0F61
A5B8B473-690B-4321-A4E4-6ECD5B6B177A
W21X50 W14X99 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 80.00 0 0 108 A992-->A992
A992-->A992
JTH_12/15/2020 2:35:12 PM 2020-12-15 17:35:21 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. 2437C24B-959B-4C95-9F8E-3B79897BA056
4B9C622C-51D9-450D-968B-30E80FD3AB91
W21X50 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 80.00 0 0 108 A992-->A992
A992-->A992
JTH_12/8/2020 9:40:30 AM 2020-12-08 12:40:31 Weld access hole preferences selected do not meet AISC a slope < 0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D2064BCF-9BD5-46A1-85D5-AEED10AE8551
08C0E473-0E82-479F-90C7-C95FC38AA59D
W21X68 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 26.69 40 0 0 0 0.00 0.00 100.00 0 0 210.75 A992-->A992
A992-->A992
JTH_12/8/2020 9:40:30 AM 2020-12-08 12:40:31 Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
6DBB0211-8B67-40C4-93FA-69D1B979466C
HSS8X8X3/8 W14X342 VERTICAL_BRACING FLANGE 0 54.45 90.00 0.00 0.00 15.41 40 0 0 0 0.00 0.00 0.00 0 0 200.1875 A992-->A992
A500-GR.B-->A500-GR.B
JTH_12/8/2020 9:40:30 AM 2020-12-08 12:40:31 Part of group with Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
C6BD7B0E-FCD8-4225-B515-5F0C0B67C7E8
W21X55 W14X342 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 31.06 45 0 2 2 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_12/8/2020 9:40:30 AM 2020-12-08 12:40:31 Part of group with Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
CEF81B52-5B5A-4468-A4FF-6569002CEC72
W21X68 W14X342 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 21.13 45 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_12/8/2020 9:25:54 AM 2020-12-08 12:26:45 Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
6DBB0211-8B67-40C4-93FA-69D1B979466C
HSS8X8X1/2 W14X342 VERTICAL_BRACING FLANGE 0 54.45 90.00 0.00 0.00 15.41 60 0 0 0 0.00 0.00 0.00 0 0 200.1875 A992-->A992
A500-GR.B-->A500-GR.B
JTH_12/8/2020 9:25:54 AM 2020-12-08 12:26:45 Part of group with Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
C6BD7B0E-FCD8-4225-B515-5F0C0B67C7E8
W21X55 W14X342 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 31.06 45 0 2 2 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_12/8/2020 9:25:54 AM 2020-12-08 12:26:45 Part of group with Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
CEF81B52-5B5A-4468-A4FF-6569002CEC72
W21X68 W14X342 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 21.13 45 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_12/8/2020 9:23:21 AM 2020-12-08 12:23:23 Weld access hole preferences selected do not meet AISC b slope >=0 criteria. (p. 16.1-396 Note 4), please update weld access hole configuration. D2064BCF-9BD5-46A1-85D5-AEED10AE8551
08C0E473-0E82-479F-90C7-C95FC38AA59D
W21X68 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 26.69 40 0 0 0 0.00 0.00 100.00 0 0 210.75 A992-->A992
A992-->A992
JTH_12/8/2020 9:19:44 AM 2020-12-08 12:19:47 Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
6DBB0211-8B67-40C4-93FA-69D1B979466C
HSS16X8X1/2 W14X342 VERTICAL_BRACING FLANGE 0 54.45 90.00 0.00 0.00 15.41 0 0 0 0 0.00 0.00 0.00 0 0 200.1875 A992-->A992
A500-GR.B-->A500-GR.B
JTH_12/8/2020 9:19:44 AM 2020-12-08 12:19:47 Part of group with Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
C6BD7B0E-FCD8-4225-B515-5F0C0B67C7E8
W21X55 W14X342 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 31.06 45 0 2 2 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
JTH_12/8/2020 9:19:44 AM 2020-12-08 12:19:47 Part of group with Framing condition and Force(s) Combination is not yet supported by Qnect. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
CEF81B52-5B5A-4468-A4FF-6569002CEC72
W21X68 W14X342 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 21.13 45 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_1223_TEST_JTH_01 2019-12-23 18:57:13 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_1223_TEST_JTH_01 2019-12-23 18:57:13 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_1223_TEST_JTH_01 2019-12-23 18:57:13 Supported connection type not found 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_1223_TEST_JTH_01 2019-12-23 18:57:13 Part of group with Supported connection type not found 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_1223_TEST_JTH_01 2019-12-23 18:57:13 Supported connection type not found 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_1114_TEST_03 2019-11-14 18:23:01 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 6BB5E477-96B5-400A-96AB-F5F1F3C51E2D
63803C82-70F4-4F8F-A532-E5E653420D02
W18X35 W16X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 10.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1114_TEST_03 2019-11-14 18:23:01 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. C8F9E7BF-DDFE-436B-8305-A84B2CB5FA1A
F14C2917-9CB8-4756-AF19-C48B8F1692E5
W18X35 W16X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 10.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1114_TEST_03 2019-11-14 18:23:01 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 7FE35383-6067-4FE5-9EF1-EF948D047A14
D5A073E1-76A6-4D17-A93D-67681AD5C6AE
W18X35 W16X40 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 10.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1114_TEST_03 2019-11-14 18:23:01 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 25DB6E0A-9FD0-4DDF-B0BF-D4BC6E1C5512
937962DF-C460-4D31-A790-F4115BB83190
W18X35 W16X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 10.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Part of group with Extended Shear Plate are not supported at Beam to Column Flange framing condition 9DE83219-BD39-4178-90E6-F43EE359215A
96B1B2EF-0790-48B3-A5F4-3DA967BBA438
W16X40 W16X50 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 15.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Extended Shear Plate are not supported at Beam to Column Flange framing condition 9DE83219-BD39-4178-90E6-F43EE359215A
5AA8206C-0908-4839-BB90-7E08A596512D
W16X40 W16X50 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Part of group with Extended Shear Plate are not supported at Beam to Column Flange framing condition F5FE834D-1AE2-4700-9E33-ECEC239223A3
BEC2535A-198C-4D88-9DEF-D60E6F4073F0
W16X40 W16X50 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 15.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Extended Shear Plate are not supported at Beam to Column Flange framing condition F5FE834D-1AE2-4700-9E33-ECEC239223A3
5AA8206C-0908-4839-BB90-7E08A596512D
W16X40 W16X50 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Extended Shear Plate are not supported at Beam to Column Flange framing condition 9AFF40D8-FE37-442E-ADB0-2B54A37E7E3E
96B1B2EF-0790-48B3-A5F4-3DA967BBA438
W16X40 W16X50 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 15.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Part of group with Extended Shear Plate are not supported at Beam to Column Flange framing condition 9AFF40D8-FE37-442E-ADB0-2B54A37E7E3E
10ADD506-081B-4BDB-8D6D-983A3967A0DB
W16X40 W16X50 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Extended Shear Plate are not supported at Beam to Column Flange framing condition 1768B19B-66EF-4585-9A76-C8B8F3F62CB9
BEC2535A-198C-4D88-9DEF-D60E6F4073F0
W16X40 W16X50 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 15.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_1112_SYNC_TEST_01 2019-11-12 17:08:37 Part of group with Extended Shear Plate are not supported at Beam to Column Flange framing condition 1768B19B-66EF-4585-9A76-C8B8F3F62CB9
10ADD506-081B-4BDB-8D6D-983A3967A0DB
W16X40 W16X50 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 2 0 0 0 0.00 0.00 0.00 0 0 120 A992-->A992
A992-->A992
2019_0926_SKANSKA_05 2019-09-26 11:59:27 Double Angles Bolted Welded are not supported at Beam to Beam framing condition 433531BD-E953-430D-A529-F9CAAE14E1B5
7C6A0920-4872-4925-A3D5-AAC281C764C6
W21X50 W21X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0926_SKANSKA_04 2019-09-26 11:58:34 Double Angles Bolted Welded are not supported at Beam to Beam framing condition 433531BD-E953-430D-A529-F9CAAE14E1B5
7C6A0920-4872-4925-A3D5-AAC281C764C6
W21X50 W21X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.95 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Part of group with Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
45BC41E9-CD90-4FFA-B42C-23D3957752FE
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0926_SKANSKA_01 2019-09-26 11:22:08 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0918_70KIP_TEST_04 2019-09-18 18:27:31 Supported connection type not found 80AB26CF-49D0-4B92-BAC2-C4496E91E4D3
93B12FB1-7A48-496B-9D63-BCCE5DF780C2
W14X74 W14X74 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 30.00 70 0 0 0 0.00 0.00 0.00 0 0 186 A992-->A992
A992-->A992
2019_0918_70KIP_TEST_03 2019-09-18 18:23:28 Supported connection type not found 80AB26CF-49D0-4B92-BAC2-C4496E91E4D3
93B12FB1-7A48-496B-9D63-BCCE5DF780C2
W14X74 W14X74 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 30.00 70 0 0 0 0.00 0.00 0.00 0 0 186 A992-->A992
A992-->A992
2019_0918_70KIP_TEST_02 2019-09-18 18:22:36 Supported connection type not found 80AB26CF-49D0-4B92-BAC2-C4496E91E4D3
93B12FB1-7A48-496B-9D63-BCCE5DF780C2
W14X74 W14X74 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 30.00 70 0 0 0 0.00 0.00 0.00 0 0 186 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.95 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Part of group with Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
45BC41E9-CD90-4FFA-B42C-23D3957752FE
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0918_LTC_01 2019-09-18 12:19:57 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.95 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Part of group with Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
45BC41E9-CD90-4FFA-B42C-23D3957752FE
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_1 2019-08-27 13:43:49 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.95 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Part of group with Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
45BC41E9-CD90-4FFA-B42C-23D3957752FE
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
TEKLA_BASECAMP_01 2019-08-27 13:42:09 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.95 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Part of group with Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
45BC41E9-CD90-4FFA-B42C-23D3957752FE
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -67.94 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Part of group with Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_04 2019-08-27 11:13:14 Not enough available space for fillet weld. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 67.94 0.00 0.00 21.58 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_03 2019-08-27 11:03:29 Non zero horizontal offset beams not supported. 728BCB88-307A-4127-B12C-009280BAC82D
19FC0B3E-49AF-4F69-9304-9F3E3A5A8A3E
W12X19 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -74.81 0.00 0.13 11.06 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_03 2019-08-27 11:03:29 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_03 2019-08-27 11:03:29 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_03 2019-08-27 11:03:29 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_03 2019-08-27 11:03:29 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_02 2019-08-27 11:01:59 Grouping contains already connected members 728BCB88-307A-4127-B12C-009280BAC82D
19FC0B3E-49AF-4F69-9304-9F3E3A5A8A3E
W12X19 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -74.81 0.00 0.13 11.06 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_02 2019-08-27 11:01:59 Grouping contains already connected members 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_02 2019-08-27 11:01:59 Grouping contains already connected members 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_02 2019-08-27 11:01:59 Grouping contains already connected members 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_02 2019-08-27 11:01:59 Grouping contains already connected members 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 40.85 31 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.04 0.00 0.00 24.15 20 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Part of group with Member rotation and/or slope combination not yet supported by Qnect. C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
45BC41E9-CD90-4FFA-B42C-23D3957752FE
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 40.95 31 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Non zero horizontal offset beams not supported. 728BCB88-307A-4127-B12C-009280BAC82D
19FC0B3E-49AF-4F69-9304-9F3E3A5A8A3E
W12X19 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -74.81 0.00 0.13 11.06 25 0 0 0 0.00 0.00 0.00 0 0 210.75 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_DEMO_TEST_01 2019-08-27 10:56:56 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0827_TEKLA_2019_TEST 2019-08-27 10:36:00 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0820_ZJ_03 2019-08-20 15:21:15 Double Angles Bolted Welded are not supported at Beam to Beam framing condition 21E6975B-42F1-4DE4-B82E-7E081F70C7EC
8A1CE34B-4836-4EEC-9D3D-3C55EEC2208D
W21X50 W18X40 BEAM_TO_BEAM NONE 1 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_ZJ_02 2019-08-20 15:14:19 Shear plate Length that is required to accommodate minimum number of bolt rows exceeds available space in beam web. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 1 0.00 -90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0820_ZJ_01 2019-08-20 15:08:44 Doubler plates on sloped connections are not currently supported. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 1 0.10 -90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0820_ZJ_01 2019-08-20 15:08:44 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 40.85 29 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_ZJ_01 2019-08-20 15:08:44 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.04 0.00 0.00 24.15 18 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_ZJ_01 2019-08-20 15:08:44 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_ZJ_01 2019-08-20 15:08:44 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_ZJ_01 2019-08-20 15:08:44 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_test_04 2019-08-20 14:58:57 Doubler plates on sloped connections are not currently supported. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 1 0.10 -90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0820_test_04 2019-08-20 14:58:57 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 40.85 29 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_test_04 2019-08-20 14:58:57 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.04 0.00 0.00 24.15 18 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_test_04 2019-08-20 14:58:57 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_test_04 2019-08-20 14:58:57 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_test_04 2019-08-20 14:58:57 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_03 2019-08-20 14:42:08 Doubler plates on sloped connections are not currently supported. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 0 0.10 -90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0820_TEST_03 2019-08-20 14:42:08 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 40.85 29 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_03 2019-08-20 14:42:08 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.04 0.00 0.00 24.15 18 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_03 2019-08-20 14:42:08 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_03 2019-08-20 14:42:08 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_03 2019-08-20 14:42:08 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_02 2019-08-20 14:35:37 Doubler plates on sloped connections are not currently supported. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 0 0.10 -90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0820_TEST_02 2019-08-20 14:35:37 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 40.85 29 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_02 2019-08-20 14:35:37 Member rotation and/or slope combination not yet supported by Qnect. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.00 -68.05 0.00 0.00 23.96 18 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_02 2019-08-20 14:35:37 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_02 2019-08-20 14:35:37 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_02 2019-08-20 14:35:37 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Part of group with Member rotation and/or slope combination not yet supported by Qnect. 09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
BE049090-A57C-4C73-A746-05B575DA6701
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 45.00 32 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Member rotation and/or slope combination not yet supported by Qnect. 09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X40 BEAM_TO_BEAM NONE 0 -0.12 90.00 0.57 0.00 23.96 20 0 0 0 0.00 0.00 0.00 0 0 -4.662353 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Doubler plates on sloped connections are not currently supported. 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 0 0.10 -90.00 0.00 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 -5.262389 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Part of group with Not connected due to the beam being sloped and skewed. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
B9C90B48-CA4F-4646-85CB-E1A71A456665
W21X44 W18X60 BEAM_TO_BEAM NONE 0 -0.04 -68.05 0.31 0.00 40.85 29 0 0 0 0.00 0.00 0.00 0 0 -4.941823 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Not connected due to the beam being sloped and skewed. 0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
F060F764-5F16-438F-A567-0AC43C85692A
W14X22 W18X60 BEAM_TO_BEAM NONE 0 0.12 -68.05 0.00 0.00 23.96 18 0 0 0 0.00 0.00 0.00 0 0 -5.258694 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
2019_0820_TEST_01 2019-08-20 14:31:50 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 -5.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
E3455F56-6C77-441E-9E49-B0B502610F16
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 63CBDC7A-526B-403B-86DB-4C0079A350C7
C0868018-EAD8-495C-93DD-349011F247FB
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 717.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 63CBDC7A-526B-403B-86DB-4C0079A350C7
89910F0B-27B8-4202-AD0E-94E703ADDB05
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 710.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
95B82989-6DE2-48B9-B276-A3BE5B79D9A3
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
2F004C04-4144-4757-819D-8F5AD6AB1D77
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
C9E9AA61-1507-4D49-A0D3-56F0FBABFA5F
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
11105D05-C9B8-4543-9935-8BF30DC3567F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 96E8B22E-A55B-4E49-B1AE-93DBB8E7B139
B85946E0-B151-46B3-AB5C-7EE106C2949A
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 704.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 82DA1330-DBB9-43D6-BAF9-FA55DAF5A601
B85946E0-B151-46B3-AB5C-7EE106C2949A
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 704.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 102F9F40-F69E-4B04-9C1E-C7EA25EBDAC3
320F0EAF-4A48-4DE2-983F-092BA8FC43DB
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 102F9F40-F69E-4B04-9C1E-C7EA25EBDAC3
D5EB0B3E-AAE9-4DBA-83AB-CFF08A57A6B1
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 555.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
931B99AA-118A-48DC-998F-2415CCF66980
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
D280C73A-C08D-487F-A744-3705A09B6F02
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
32E62B4F-C42B-4BF7-ACE0-E9527C08212A
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
7302AC94-6AAA-4074-B10C-8CCF69ED0822
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
6A4821E2-4EBE-45F8-90EC-6D046B9BE460
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C0DC1D29-B95B-455C-8F0F-42CF6E13E511
29885E5C-5D06-4F43-9B03-6AE34B8DFC4F
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C0DC1D29-B95B-455C-8F0F-42CF6E13E511
DF6E91C7-C2F9-4DD1-8272-51B4651C7493
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 717.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
5F1B7032-3A52-4989-B879-06F9EEB16408
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
D264C0DB-971B-4C14-9B9E-4B0CA73C2380
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 33 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
82DA1330-DBB9-43D6-BAF9-FA55DAF5A601
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 726.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
65ED1B56-34CC-48F1-81AF-71B20A491C88
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found ACEC7EE8-E7E7-4F4D-8481-ED07320975EE
CA26147F-22AF-4CD3-B3B0-1B5207F36E4A
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 866.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C72C2A0A-A691-4CC3-85A7-2EBB25E257A9
CA26147F-22AF-4CD3-B3B0-1B5207F36E4A
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 866.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
17B9D283-6F78-4A8D-A0CC-990DE348DF3E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
E7CBEDAB-69C3-45A7-A3D5-C0F728DB19F1
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 09BEC59D-D492-43E8-85E0-394F7BEF0944
C3F345F6-F2BB-4DCA-8EE6-4BACD56C9553
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 09BEC59D-D492-43E8-85E0-394F7BEF0944
C51E46BF-F581-40BB-8AEC-A03B2C4D70BD
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 5A8D2266-D756-4EE3-9B78-B45383C14CCB
4438C802-559A-4870-81C1-86E265FA5D78
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 879.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 5A8D2266-D756-4EE3-9B78-B45383C14CCB
6F37BAC4-4727-4C67-9905-50B75D23F54B
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 872.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
066830D0-02FE-4B7E-B3D0-A0D3A07842BF
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
7B3915A2-4E86-4237-909E-8343BB141695
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found CE568E02-A0A7-472A-8E17-8219D9C19567
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 0C608DA6-3310-40FE-BE53-8DAA2337F78A
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
71FDDDA4-89E1-445C-99A7-F0FBA6F6B2EE
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
859C0BFC-B315-4D57-9424-90E381D489C0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 19 0 0 0 0.00 0.00 0.00 0 0 386.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6443C939-BA0F-4583-AD17-6DF35322A218
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found A8B3F9E3-164F-4779-A235-529A1E135F45
CB7B1D3B-76F7-4477-9968-EF5E1395A644
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1676.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 68374965-673C-4F2A-B6E8-1E2A35BB5D67
CB7B1D3B-76F7-4477-9968-EF5E1395A644
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1676.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
0A840E7D-FE17-48F0-853B-F0354F51F022
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 37.00 20 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
8C8E4204-FD56-4C17-A310-8FC4B169C161
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. B55504D3-7F37-454C-944C-446549C20C06
6BF713A5-D26D-4C64-9EBB-49FCDFDF8510
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. B55504D3-7F37-454C-944C-446549C20C06
A9D2C600-B964-41FD-A64F-191BF7954FEB
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 6772C9AD-A31C-4F13-BDED-9E3B86D17F45
4964FF3A-30AD-4B6E-AD24-9D63D1CD9687
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 6772C9AD-A31C-4F13-BDED-9E3B86D17F45
7FAA0D8B-BCB2-435B-B446-55B339A528BF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 996F345B-F848-4BD6-B9B8-C05B0BA48C0B
B01771F2-C56C-4FAA-B179-0A0293877130
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 996F345B-F848-4BD6-B9B8-C05B0BA48C0B
BC4596AA-E2EC-4951-BE24-17C999455503
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. EB8F8740-1C62-48B6-9391-56EF77C970A7
F499BF06-D470-4C59-A269-2860205CEB62
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. EB8F8740-1C62-48B6-9391-56EF77C970A7
781921F8-16DC-4148-8A36-F1768EB28D13
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. C384AEFB-93B1-4BAF-99FF-9FE8969585A1
623CD3B8-2DDE-48A8-9179-C09E4F2A953F
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. C384AEFB-93B1-4BAF-99FF-9FE8969585A1
8E9C9035-804B-4E3B-9AA4-0FF258D307CB
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 5B81CDC9-D34A-4F23-953F-0A70F4067335
A478FA25-CD9D-45C2-8819-EA1D38999AFE
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 5B81CDC9-D34A-4F23-953F-0A70F4067335
669E2DB9-13EC-41BB-B90B-E1FC1771F01B
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
045857FD-8CC8-4FA5-9198-44108B9D1C7A
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
B905892F-0103-4F20-A36D-E6A79D3E28C3
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. DE88244C-FCFD-4BF4-A5F8-CD84C1391B2E
BF59EB36-FC17-433F-BC47-8F8FEABB62C6
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. DE88244C-FCFD-4BF4-A5F8-CD84C1391B2E
9898D96D-B47E-49F4-B0B5-A17F8E2D18E7
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 8BBE0AD7-9672-431B-A9C0-ECB390DC4FE9
68629880-6514-4640-8892-C9683773A454
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 8BBE0AD7-9672-431B-A9C0-ECB390DC4FE9
CE40D5F0-55E8-406B-AE97-CA63B3382678
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 615CD836-586C-4899-A8EC-E5CBF071A8C7
CC020A15-079C-44EB-A5D5-9B9635CEE6E7
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 615CD836-586C-4899-A8EC-E5CBF071A8C7
84D48DB1-0315-4082-9C76-2FC7741E1750
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
AFFBBDDE-73B9-4003-8175-6176D0CB34F8
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
8CBAB442-DBF1-4C66-B53B-4FFA6E0280BA
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 72D8C652-06C1-4AA6-BDC9-B915F514A9A1
04360B31-EEEE-4164-84AA-258CA6D852E3
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 72D8C652-06C1-4AA6-BDC9-B915F514A9A1
088F9D9A-1CED-4557-969F-0ACA8C2ED545
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
C1948D85-AF84-4861-B057-7FC78370C5F5
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.54 62.6258 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
8B4F079F-D09D-4D0E-BB02-F4A5D9CF735D
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.54 62.6258 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
58A1B05A-7903-43EF-A425-DC709650E9E6
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. AE7BB2C3-935A-48D7-96D5-1121EF0D4258
4504EDC8-3A09-4215-9314-EAB179B09449
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. AE7BB2C3-935A-48D7-96D5-1121EF0D4258
1745BC85-9DE7-4880-85C8-592FA4BB0EDB
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
9A3C04DC-F450-4CE9-A274-EF14EB6B30EC
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
28B9CFF1-406D-439C-8819-E8018BEFA460
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. BD9E7DBE-EC69-49EB-BB12-3F8E102D02D8
F7AF3102-8854-4D06-82F9-F2C5877BF023
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. BD9E7DBE-EC69-49EB-BB12-3F8E102D02D8
32D506C1-860A-4D54-9303-444FABA75B5D
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
C6A484D9-D416-4073-A724-F871B155C244
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
6AC81F90-4F75-4D08-B133-7161F81823E8
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 6625312C-E5BC-4F88-972F-EDDB5B753FC8
A2011AE5-2184-4F99-BE95-9E370D222C1E
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 6625312C-E5BC-4F88-972F-EDDB5B753FC8
1EA58967-EF88-40B2-9089-07D10B2BEF0C
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 39575AB0-8076-476E-925A-81523D3C3F60
509C1B55-BB97-481C-9A79-01414B6D73C4
HSS16X8X1/2 HSS16X8X1/2 BEAM_TO_BEAM HSS 0 43.99 0.00 0.00 0.00 16.00 60.8108 0 0 0 0.00 0.00 0.00 0 0 2033.61 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. C59419E9-8972-4BF5-9C20-03A9CDDC97B5
28466171-702E-4572-BCF6-5B4095ED79AF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. C59419E9-8972-4BF5-9C20-03A9CDDC97B5
92E0E35E-D538-4D44-A6B6-BCF4750ABBF2
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
1BD0A2F8-FBB7-4BDB-935A-7802F28440AF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
F3FAB671-F5DC-4165-8300-1875CBC0E5D8
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found ECB6AA23-46AF-469E-A288-4C6D229D320C
DA2AC3F8-B4D1-45A2-A3FF-4FE6C2706381
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found ECB6AA23-46AF-469E-A288-4C6D229D320C
BDB3FE16-6945-458A-8933-85A218E5D653
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1682.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8AED7CB3-1990-48B2-849C-E530631ED92C
5412E813-E2FA-4985-81FF-6AB33880D03F
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 555.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8AED7CB3-1990-48B2-849C-E530631ED92C
86F09C66-F195-46C4-987A-9346B1F7608C
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 548.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 2DFE2DB3-B007-4F74-9E03-FAD3F1C597E8
DABCDC7E-620B-4F0C-9EDD-D2301FE53B5F
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 542.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found FE9B06A8-5CE8-4ACA-9F29-DC4D84366934
DABCDC7E-620B-4F0C-9EDD-D2301FE53B5F
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 542.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
34F41067-F048-4FF6-A5F6-771A14541DF9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 7DB6F78D-008F-4DC2-BC7A-72F695E45D03
EE83B50C-847A-45C1-8EC4-E09D213CC957
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 7DB6F78D-008F-4DC2-BC7A-72F695E45D03
65FB6C5C-7E18-499F-B901-66E1DDA96982
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
01C64280-8BAA-4E7A-82AF-5966A61F003C
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
BE2F0B52-28FF-4142-B5BD-CDD8126F7653
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
2D9130AD-4510-44A0-801A-A9B40200F63F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
C97A5DFC-F1A6-40D5-88FE-41A41A19BE96
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
F697EB99-F1D5-42C9-8713-4D01B659EB10
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
FE9B06A8-5CE8-4ACA-9F29-DC4D84366934
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 564.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
3D16E87C-0E63-4FB4-9A26-87FE602ADB2B
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6B3D27A1-140A-4C85-8EB0-D3E348B70ADE
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 110FDB7D-E948-4EE0-A8DB-5F78B2E4CEB9
C645ACDF-CBF4-49CA-BDDB-73A50A41CA39
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 44.98 33 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
0571F1DD-D7FB-4E06-9599-FF362E17573E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
1C8D917F-19CA-4C8B-82E0-73668B1F3B50
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
AE661D55-0C27-496D-A36F-9D11085D9593
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
A56ACB7F-DE4A-4F17-8843-A463A3291C8E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
2B830D0D-5244-4BCB-A197-D75F75B6EA64
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 1A9F0913-08EF-46F0-AE77-6CD40D1B3689
668E387A-03FF-49A1-8633-494287969E45
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 1A9F0913-08EF-46F0-AE77-6CD40D1B3689
56AA7C1A-BDED-4946-B631-4A4B2F1F7BE5
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1365.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C7213124-48AA-40CB-B8DD-61160DF07882
3364F58C-2A85-4490-9A89-43F0A313E179
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1352.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 73D4FE4C-6B7E-4FC6-9DD3-1EB6DBCDA25A
3364F58C-2A85-4490-9A89-43F0A313E179
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1352.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
04F7C4C1-59B8-4E10-AA17-24920B3B79FE
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
24F99231-0646-459A-8DEB-9F5A68FC13E3
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
874EA2FE-03B2-40C4-9EAD-C394C8A5E382
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
DBD48ED0-AB5B-41C2-BFFB-B2D37F79AFDC
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
B0AE673A-D765-41E0-B4A7-F04A88E8C666
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
73D4FE4C-6B7E-4FC6-9DD3-1EB6DBCDA25A
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1374.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
90CEF738-9F74-4C30-AC0A-C66B721CB70D
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 33758C8D-DEE0-42C7-9857-E163188E4C4F
D87DF215-2550-472A-B2D9-679A849D59F1
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 33758C8D-DEE0-42C7-9857-E163188E4C4F
E8C34D8B-B6BB-4A26-918D-B164D64C11A8
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found E58A3383-350A-4BAA-8926-F472E1C00DDD
E88B5E59-E8B3-4A7C-B9AA-A9735B1D559E
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1365.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found E58A3383-350A-4BAA-8926-F472E1C00DDD
E4031D49-3511-42EA-A012-EFC26269BFE2
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1358.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
6F8F9D4A-CE65-4795-8D60-0CF84203B0CC
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
1C3665B1-9EB0-4E76-977C-038EE62A6D7E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 4BCF7AAF-F7CF-47A4-846C-5E2B9AC9AE1F
A45BC3F4-DCBE-4D0F-88A3-8A9670C5E792
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 4BCF7AAF-F7CF-47A4-846C-5E2B9AC9AE1F
474A1855-92D5-4B39-BE82-668B65BE022D
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1527.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
A195001E-5C5E-4E8D-ADE6-6C345637860D
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
B67002EA-0261-4230-ADD3-63C4590893D8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
0457DCC2-4F3D-4961-926B-E88CC6758B95
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
B94B496E-32E7-44D7-9940-1B2A5823C919
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 981E3662-7F39-4A6E-844B-57666BCC7635
3502BAFE-BA8B-464D-B6D0-AF989338A829
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1527.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 981E3662-7F39-4A6E-844B-57666BCC7635
D0504C92-D235-4631-BF87-03B9AE455123
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1520.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
01870393-240A-4DCE-9A6D-29C866AA14B7
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
BF09E36F-D0F0-470A-9955-FFF6BD961210
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1536.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
2D5287EF-1A68-44EB-9C07-3D2B74835D08
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 9ED7B62F-8CF2-4A54-821D-1C08FC0622BB
72C22C63-26E1-416E-9CB9-3091702BBB08
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1514.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found BF09E36F-D0F0-470A-9955-FFF6BD961210
72C22C63-26E1-416E-9CB9-3091702BBB08
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1514.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
3444EC51-F48B-4E72-AD90-32797CFCA793
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
16832A5A-5232-4077-94FA-1AFF62650811
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
74310FA7-D4E9-4517-965D-DB61F51CBD12
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
3E6E7C1A-F341-43B0-A948-DCDA985BA9B9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
5821C6D0-4886-4FD4-A652-DE1DE25B2E55
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
527086CD-4698-4E1C-B8E6-A4DB576B4ED9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
910EFF2B-04B1-4E77-8A60-B659AF810FB8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
B5561713-1D05-406C-BC9C-2547074C83A8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
90B14FFD-85F1-4AC9-AE6C-3E8A546AF3A0
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
C72C2A0A-A691-4CC3-85A7-2EBB25E257A9
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 888.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
35E0C90C-B657-4477-A0F9-49E698E6DF8C
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found D685F3E4-DBB2-434E-AA60-4A44443B904E
A31F9A03-3BF9-45BD-9D4D-F468B38694D3
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found D685F3E4-DBB2-434E-AA60-4A44443B904E
317C330F-56B1-413D-B5C3-767C5EE23AF1
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 879.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 36938698-4BA9-41BE-917B-A36EB9A0FC7B
A61582FF-4E92-42CC-A7E1-0303A16F334C
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 36938698-4BA9-41BE-917B-A36EB9A0FC7B
FC6D22D0-DA9F-48AD-9B93-B5DE71C616A6
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found CAC614D6-3930-484F-9374-2165D64F88CF
C10C402F-F9B9-414F-BF73-9C4E42A5B8E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1041.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found CAC614D6-3930-484F-9374-2165D64F88CF
60298E80-7C71-44BB-AA04-8BCB0B4D7B17
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1034.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
F9D1D7F0-91A1-4BD2-8B22-567189A43574
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
B8C2A21D-70E3-497D-AAA5-49E1CACEDA37
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1050.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
39E40769-ADCF-4156-A4B9-F3374555D34D
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 57578118-5DED-465C-8EB1-C8D1958EA3E8
4220FC9B-2BA6-4C93-BE06-3D34A5946ECE
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1028.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B8C2A21D-70E3-497D-AAA5-49E1CACEDA37
4220FC9B-2BA6-4C93-BE06-3D34A5946ECE
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1028.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
D02A7757-F456-43A0-B59C-B93DCC19A86B
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
61D4E711-4FD5-4186-A4E3-CFD5C8A639C6
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 51BA6D0D-66C8-4B79-9BBB-B9BF56E39A4C
1AEFBAB5-F3AA-4B0B-8600-A3F6B3EF173F
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 51BA6D0D-66C8-4B79-9BBB-B9BF56E39A4C
4E21892F-B6A4-4DCC-9F2A-9E5B9C687224
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1203.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found ACA670B3-1EC5-4084-9B6A-E01562621B83
B9213A9D-DB05-408D-BE45-4DA9572D3712
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found ACA670B3-1EC5-4084-9B6A-E01562621B83
276B19D4-38A7-4793-AAA1-2D63619FDF9B
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1041.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
AEB73A92-1F8B-41BB-8C02-EA917305324B
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
7F0E6AD2-5981-48AB-AEFC-FD4C32B58530
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1212.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
7FDD9D51-1633-4172-91DA-BEF3BC95E365
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
E96BB49F-6910-4A35-8DCA-EAA699AD4977
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
C4FAC400-9543-4B25-8057-1A6BD4896836
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
FFC21D70-D788-4D4E-8A2A-C03B634BB7D9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
144D2F6D-5C1E-4F9A-9710-4D74C63134EA
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
2A18F2B2-1E72-4FF2-95BC-6ABDD3074436
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1190.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 7F0E6AD2-5981-48AB-AEFC-FD4C32B58530
2A18F2B2-1E72-4FF2-95BC-6ABDD3074436
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1190.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
11EE248B-4BB8-45B9-A582-84EA198C8FD8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C0139783-4A96-4DFD-BC58-47B07868F60A
873E4496-E6AB-4C12-8905-D05CD4E58F7F
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C0139783-4A96-4DFD-BC58-47B07868F60A
5864D340-9DDE-400A-8297-FB64DB071ED1
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 4778A2A0-A24B-4576-A05F-6455A86A3E86
083F3028-0C75-4E10-BC6C-B6C1C5A8937A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1203.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 4778A2A0-A24B-4576-A05F-6455A86A3E86
F19B8712-1AFA-4F4D-B854-9E9E20B18CE0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1196.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. DD10C239-456B-42DE-8ECB-76ADE840A197
3469D7EF-A378-4DD2-9B4E-81ED9840DB64
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
9216A95C-39D8-4394-A7B7-D2065F6D9E5F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. E0B08B4B-BC81-4005-AAC6-417BF00C352B
688A86B8-2381-46D6-A25D-D5B51C8C2797
W16X26 W21X50 BEAM_TO_BEAM NONE 0 -0.96 83.00 -2.64 0.00 12.38 35.6335 0 0 0 0.00 0.00 0.00 0 0 12.985 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
E46D4443-4EE3-40CE-A6A8-A53E76993D59
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.64 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 2.61262 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. 0CD686BD-D8D9-4987-A7F0-569583C5C2C8
ED1C1A21-79A0-4CC0-8B0B-FCE7C2B8DE91
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.86 83.01 -6.06 0.00 15.39 13 0 0 0 0.00 0.00 0.00 0 0 6.56707 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 0CD686BD-D8D9-4987-A7F0-569583C5C2C8
4903CA7E-E6AD-4343-AC38-7B6167850BB1
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.03 0.00 44.94 33 0 0 0 0.00 0.00 0.00 0 0 15.6509 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 98BA463C-687B-46FB-8CE4-D5699B97A882
1E6A7B70-E773-4D07-84EF-18E10E3114B9
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 1.67 0.00 45.00 37 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
E04120CC-0459-4255-B85D-4C65CA61E872
W8X15 W40X167 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.50 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found DFDB1767-0816-4897-85BF-BD729573A8A0
E04120CC-0459-4255-B85D-4C65CA61E872
W8X15 W40X149 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.13 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
8F138495-EC97-4145-AE55-72D8AA4FB1AE
W8X15 W40X167 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.50 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found DFDB1767-0816-4897-85BF-BD729573A8A0
8F138495-EC97-4145-AE55-72D8AA4FB1AE
W8X15 W40X149 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.13 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. B42E0558-18D9-4C70-8132-288D5DAE0E56
C8457151-2FA7-4126-A970-0F262F0199F8
W18X35 W14X22 BEAM_TO_BEAM NONE 0 0.00 -83.09 4.00 0.00 3.51 189.042 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 37D52133-8A74-4741-922F-B00B51799C54
6EF1C0C9-B8C1-4CF2-AFEA-14C05C76E5B8
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 37D52133-8A74-4741-922F-B00B51799C54
49F12458-B474-43E1-BCF7-D75F441EE50E
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
B6F414E4-B7A7-46EE-A141-9B5F17F4A126
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
FF7A9395-D400-47A7-8098-A26BD6B77104
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
7FEAA7D1-8B13-4323-A9A9-61145FF35CD8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
1A488E75-E700-4CCF-96D5-2CDE648BC4F5
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
3445C3F2-BACD-4EAD-88E7-ED1AF860A921
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
A8B3F9E3-164F-4779-A235-529A1E135F45
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1698.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
A779A281-E3BC-4125-A535-E6289CB3F459
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found DC6DB2A9-3885-4421-B0E3-E96E06A3292C
59A05F6D-79C8-4822-B3D4-9C3771A73A58
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found DC6DB2A9-3885-4421-B0E3-E96E06A3292C
5D2155DF-F903-47F5-8117-90FFA45107C6
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found D731B8AB-F16E-4E58-8CF8-9D461F1801BF
67BFA688-A1F6-415F-BCF0-F7362C79DD89
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 231.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found D731B8AB-F16E-4E58-8CF8-9D461F1801BF
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 224.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found D0D59AF9-4838-4A07-9619-2715740F8C0C
C9FC156E-5435-45E4-B3AA-EEC60787CBDB
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 218.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found D5B94786-A91C-4967-982E-220EF3465CED
C9FC156E-5435-45E4-B3AA-EEC60787CBDB
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 218.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E8847A70-26EE-4F36-9DD4-E5D72960DFF1
C8457151-2FA7-4126-A970-0F262F0199F8
W18X35 W18X35 BEAM_TO_BEAM NONE 0 0.00 -83.09 0.00 0.07 3.51 189.042 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E8847A70-26EE-4F36-9DD4-E5D72960DFF1
B8C27D76-6DC1-4E0A-A4CA-D0D29A8D3CCA
W18X35 W18X35 BEAM_TO_BEAM NONE 0 0.00 -83.02 0.00 0.00 19.88 11 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
1B6BF262-F900-4B02-95CD-DD60792C309F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. DFDB1767-0816-4897-85BF-BD729573A8A0
B5257666-8BDF-4CB1-B5B5-2FE0F1608142
W8X10 W40X149 BEAM_TO_BEAM NONE 0 0.00 -90.00 -30.38 0.00 5.63 15 0 0 0 0.00 0.00 0.00 0 0 2018.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
3E81227F-89E2-48F3-A9E8-76C9CAC23401
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -6.00 0.00 10.65 17 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
A84E7E56-49D9-425D-9A4A-F21BECA72F79
W21X62 W18X40 BEAM_TO_BEAM NONE 0 0.00 -84.50 3.12 0.00 22.93 35 0 0 0 0.00 0.00 0.00 0 0 1852 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. CEDE7528-6B1F-4D50-850A-9A5102A35EBC
181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
W18X40 W21X55 BEAM_TO_BEAM NONE 0 0.00 84.49 -2.88 0.00 33.10 34 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
5880CE72-5088-4AC8-BB70-5ABD1DE92D1A
W12X14 W40X167 BEAM_TO_BEAM NONE 0 0.00 -90.00 -26.75 0.00 6.04 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8E614244-7AF7-4A01-B44A-D5C5B158C354
5EF07686-B1FA-445D-8F9D-097EDA5F62FB
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.88 0.00 45.00 40 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8E614244-7AF7-4A01-B44A-D5C5B158C354
4D788503-5989-4F67-92E6-83A453F14569
W16X26 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.13 0.00 24.05 27 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. F614BD41-ACF5-4D7A-BA1A-6EAE5E242BFC
EB0A5650-5372-4B64-95AC-FC05B4CCD970
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 10.23 30 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. F614BD41-ACF5-4D7A-BA1A-6EAE5E242BFC
AA230C34-B299-4560-A4AD-F18C88234A2E
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -88.61 2.00 0.00 20.03 13 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. AA230C34-B299-4560-A4AD-F18C88234A2E
DA837A15-17E7-474D-8AEB-C78E6E5123D4
W16X31 W18X35 BEAM_TO_BEAM NONE 0 0.00 88.61 -1.88 0.00 3.93 137.136 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. AA230C34-B299-4560-A4AD-F18C88234A2E
05CC3659-5B33-490F-A674-98B9FEE33018
W16X31 W18X35 BEAM_TO_BEAM NONE 0 0.00 88.61 -1.88 0.00 35.84 15.0378 0 0 0 0.00 0.00 0.00 0 0 2284.37 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 9653A074-7541-48AF-AE0C-04A23F47DA27
3469D7EF-A378-4DD2-9B4E-81ED9840DB64
W14X22 W10X12 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 62FDF846-535A-4AA7-8554-D2F2C04F3267
9653A074-7541-48AF-AE0C-04A23F47DA27
W10X12 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.88 0.00 10.00 20 0 0 0 0.00 0.00 0.00 0 0 2278.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. E3990C09-536C-417B-B9E9-D92B585C9D73
077A8702-D39A-4573-BF04-B671CAC7F09C
W14X22 W18X35 BEAM_TO_BEAM NONE 0 -0.90 -83.00 -1.83 0.00 11.65 30 0 0 0 0.00 0.00 0.00 0 0 2192.42 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. 6A53AD67-6333-455B-9F59-0F2226A0B78B
077A8702-D39A-4573-BF04-B671CAC7F09C
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.90 -83.00 0.00 0.00 11.65 30 0 0 0 0.00 0.00 0.00 0 0 2190.2 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found E8A24FF6-D411-44C7-892A-FA1889F00148
99258A7A-0375-4955-8AD1-40235B3F4D91
W21X55 W21X48 BEAM_TO_BEAM NONE 0 0.00 90.00 0.13 0.00 45.00 51 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found E8A24FF6-D411-44C7-892A-FA1889F00148
A2B1A411-789E-4F1A-AFC3-123CD3E9B0F5
W18X40 W21X48 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.75 0.00 34.90 38 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
0542B7B5-89B7-4B84-9C92-9888D6C9A966
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 290C7D84-5C46-41F5-A6FD-8B8501FAD362
77E41864-354F-49AA-9333-A1F07AA779E4
W18X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 0.12 0.00 32.38 25 0 0 0 0.00 0.00 0.00 0 0 1848.87 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. 67B642D8-87C2-45AE-80D0-CCC5901103AE
290C7D84-5C46-41F5-A6FD-8B8501FAD362
W18X35 W21X201 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.25 0.00 10.00 66.3834 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
9C51C74D-F5A7-415F-9C4E-37D8F0B1D5A1
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
12F39FB7-FCEF-4F22-815A-BD027E380E53
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
C0CB8698-7ED5-4EF1-B390-EDFC8E7735D5
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. 705D515C-E499-4482-A35F-A4BB13F49404
40CE5947-F5CD-46DF-AEE0-046EA836D0C0
W12X14 W18X40 BEAM_TO_BEAM NONE 0 1.17 83.00 -6.08 0.00 10.60 25 0 0 0 0.00 0.00 0.00 0 0 6.54677 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 705D515C-E499-4482-A35F-A4BB13F49404
598F64BB-7501-4831-8B36-1C12FB2C40E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 44.92 33 0 0 0 0.00 0.00 0.00 0 0 15.6248 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 90686697-E1FE-4886-8998-19A5F135BE4B
09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.63 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 12.624 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
BE049090-A57C-4C73-A746-05B575DA6701
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.98 0.00 45.00 32 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 1F15AD9A-5A71-4CE6-9828-DA0D947A6915
06E2CFCC-7D25-4E64-8D50-3A3A180CB582
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.03 0.00 44.90 33 0 0 0 0.00 0.00 0.00 0 0 15.6509 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. 1F15AD9A-5A71-4CE6-9828-DA0D947A6915
83E58AC3-D197-4030-960B-1CA3BB154A00
W12X14 W18X40 BEAM_TO_BEAM NONE 0 1.03 83.00 -6.07 0.00 12.99 11 0 0 0 0.00 0.00 0.00 0 0 6.5562 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8B36CDC3-2492-42CC-BDA9-7969886A81E0
8A72BC96-3E03-419F-830C-87524A0B7564
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 8B36CDC3-2492-42CC-BDA9-7969886A81E0
B72C4284-5819-4764-929C-560F75E2C85D
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 231.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
0D9E4A9E-DE97-4127-BCCB-8F4F5C561506
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
D0D59AF9-4838-4A07-9619-2715740F8C0C
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 240.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
C0A7913B-9597-4B2F-AE0D-392C249E35E6
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. A40D0707-CB63-494F-B78F-83BF153E7098
15CBF671-1A7F-48E0-A322-40A3772FB251
W14X22 W12X16 BEAM_TO_BEAM NONE 0 0.00 -90.00 1.75 0.00 20.13 16.464 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. FE52CDED-369B-4256-AA0A-3DACCB1205F5
A40D0707-CB63-494F-B78F-83BF153E7098
W12X16 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.75 0.00 23.98 8.36555 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
A07C5B85-BC0F-4A88-B230-F16391582374
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
90C93110-BFCC-4941-9EE0-1AEE00CCCF40
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
0FC65D40-AF42-4477-8454-4987A20902E9
W21X44 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.75 6.00 28.94 25 0 0 0 0.00 0.00 0.00 0 0 2031.37 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
DDA37837-B098-4927-B57D-C9D43D6E426D
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -6.00 0.00 10.68 17 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 97E1E225-1274-49B4-96F0-9C15B10FE79A
4877E884-471D-4F45-8222-520CF12C4AAD
W12X16 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 -5.75 0.00 10.68 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 97E1E225-1274-49B4-96F0-9C15B10FE79A
61C66E6D-542E-4BF3-9658-90E04ECE8007
W21X44 W18X35 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.88 0.00 36.94 31 0 0 0 0.00 0.00 0.00 0 0 2031.37 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 3179739E-F7B7-4E7E-AC14-C1C6A351F7FA
D48B9EE2-BA8C-440F-86B8-335673D9AD8A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 3179739E-F7B7-4E7E-AC14-C1C6A351F7FA
9D1687C6-9FB1-4150-B96F-912EECF9E030
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1844.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 775F59CC-D207-424C-943C-45AD46BDA2C0
AB612E15-8AC9-46E8-9928-FF22A75103C0
W16X26 W21X44 BEAM_TO_BEAM NONE 0 0.00 83.01 -4.88 0.00 15.33 16 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
D609A66D-9839-42BC-92F6-58A3E24E5425
W21X55 W21X83 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.63 0.00 45.00 51 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
704847F5-1E77-4AC8-81D5-37A5BB35BFE0
W18X35 W21X83 BEAM_TO_BEAM NONE 0 0.00 88.05 -3.63 0.00 36.00 37 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
E8A24FF6-D411-44C7-892A-FA1889F00148
W21X48 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 44 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
00D94FA7-CFDE-4CDD-AC5A-6AE0166249D2
W12X16 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
827C55CB-7061-4844-ACF5-05A59FB1CBCA
W16X26 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 29.00 19 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. B50EB32B-3D8D-4945-8CE9-CA3A09181C22
5E8847C6-3429-41E4-83AB-50CC44966987
W14X43 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections to a girder where there is a column flange above or below are not supported yet. E7EC1C34-E0C9-4388-A987-906874F4FE8A
B50EB32B-3D8D-4945-8CE9-CA3A09181C22
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 19.94 16.6145 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 68E06054-293C-4849-BE0D-A5697055AF9F
69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
W18X35 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.25 0.00 20.00 35 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 68E06054-293C-4849-BE0D-A5697055AF9F
FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
41CD1199-5009-48D1-A5A3-FF28C3976D73
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
W18X40 W18X46 BEAM_TO_BEAM NONE 0 0.00 -79.50 -0.13 0.00 33.10 31 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
C4BF2FC5-B3E0-4AC0-995E-51F2D054DEB5
W16X31 W18X46 BEAM_TO_BEAM NONE 0 0.00 -79.50 -2.13 0.00 30.44 24 0 0 0 0.00 0.00 0.00 0 0 1846.87 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
5D257874-B649-4E3D-B083-C64788065277
W14X48 W18X46 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1849 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
4E134221-1035-49CA-B35E-A781B5D4DEBA
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. FD3D037D-5494-438B-9070-EDDC0EA5C82B
26E1EE41-9A11-4EEE-9339-250EB4E1E041
W14X43 W21X111 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2032.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
W18X35 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 20.00 35 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
C276519D-931D-4557-A516-97AAA2C95482
W18X35 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
AC8034FB-ABF2-4728-8CC7-4E64639E9A9B
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 56148724-7135-4712-B68F-305F3B27138C
F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 56148724-7135-4712-B68F-305F3B27138C
9CEB8268-1533-4B64-8788-FE214DA33696
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 34 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 9CEB8268-1533-4B64-8788-FE214DA33696
24DB69A2-3F16-4127-85BA-1827873B72C4
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 213A3419-B118-497F-B4ED-EF9E22803A70
DA3A0C2D-E764-4BC9-8723-5B11909E3C86
W18X35 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 32.52 18 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. DA3A0C2D-E764-4BC9-8723-5B11909E3C86
8CC17800-B31A-4419-9B5E-B83A51B6C175
W18X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 0.13 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. DA3A0C2D-E764-4BC9-8723-5B11909E3C86
06A762CD-6FFA-4D78-8266-515E368F9689
W14X61 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
F8A51DB3-7C7F-4902-B159-1D423CDA90B9
W21X68 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.50 0.00 20.00 20 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 628C0350-A369-48A2-99B0-7FE05F1B8B72
E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
W21X44 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.50 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 628C0350-A369-48A2-99B0-7FE05F1B8B72
2E59BE03-0547-48CE-8014-6690D872C9C7
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. DADA8014-282F-4963-9986-BCFC63188B6F
DA8352A9-E9A4-434F-9E54-A9F6605549E0
W21X44 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 8.50 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. DA8352A9-E9A4-434F-9E54-A9F6605549E0
712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
W21X55 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.13 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
64AE8F49-4E1E-4611-939D-C22BF7153D67
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
DADA8014-282F-4963-9986-BCFC63188B6F
W12X19 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -8.50 0.00 20.00 11 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 3E7EE27E-60E7-4496-AF67-6DA72A755BA5
06EFA10C-AC85-48E2-BB76-4CDD620AB53F
W14X68 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 37D52133-8A74-4741-922F-B00B51799C54
69BF29A6-1BF7-4491-8DED-14279ABDF205
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 88.05 -2.88 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 786212BB-2A21-4285-8839-203B1E887441
313E3F6D-87A2-4330-8BD4-7291B3E9511D
W14X90 W21X50 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 36.06 0 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 786212BB-2A21-4285-8839-203B1E887441
37D52133-8A74-4741-922F-B00B51799C54
W21X44 W21X50 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.25 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1689.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 786212BB-2A21-4285-8839-203B1E887441
C2FE6BF7-F3CB-4951-A189-0B9928695D8A
W18X40 W21X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.00 0.00 20.00 29 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. D9774C64-813D-425A-921B-5050D603A4BC
BBCA9207-8685-48F3-BD48-5586F1327BAE
W14X48 W21X93 COLUMN_TO_BEAM BELOW 0 -90.00 -7.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. D9774C64-813D-425A-921B-5050D603A4BC
B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
W18X60 W21X93 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.38 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
6E81C378-9254-4005-87E7-E622140A8BD9
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
5E8847C6-3429-41E4-83AB-50CC44966987
W14X43 W21X55 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 1281E5CB-B4F0-449C-9E64-513FC966FD48
68E06054-293C-4849-BE0D-A5697055AF9F
W18X119 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 1.13 0.00 45.00 65 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 68E06054-293C-4849-BE0D-A5697055AF9F
2ECEC8F6-06D2-496F-8E27-AFEF34276840
W14X43 W18X119 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 338638BA-B2D9-4CA4-9AC1-2EBE0423FC15
1281E5CB-B4F0-449C-9E64-513FC966FD48
W18X40 W12X16 BEAM_TO_BEAM NONE 0 0.00 -83.02 5.88 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. FC07D5E4-4C1C-4879-AD88-0F9340F1CE4E
338638BA-B2D9-4CA4-9AC1-2EBE0423FC15
W12X16 W18X40 BEAM_TO_BEAM NONE 0 0.00 83.02 -5.88 0.00 11.73 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 628C0350-A369-48A2-99B0-7FE05F1B8B72
A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
W18X40 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.25 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
45B3614A-E04B-4F6A-9E54-7097C38E26A8
W21X68 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 3.25 0.00 20.00 20 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 45B3614A-E04B-4F6A-9E54-7097C38E26A8
ED50100C-D93B-43EB-972A-70EDBA07BF0E
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. C0F54A76-A2F7-47C9-8320-E638CBB91E0C
9DBA1190-D366-4F39-9406-FCE8BDDB6335
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 19.94 16.6145 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 9DBA1190-D366-4F39-9406-FCE8BDDB6335
9A43B315-F54F-4EE0-819F-F5748C979535
W14X53 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections to a girder where there is a column flange above or below are not supported yet. 9DBA1190-D366-4F39-9406-FCE8BDDB6335
E7EC1C34-E0C9-4388-A987-906874F4FE8A
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. DADA8014-282F-4963-9986-BCFC63188B6F
6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. E8607EB6-0BF5-4218-9C92-8EE0225AA17A
9CE6EB0B-EAF3-4FF6-873D-BD8DB74FD3B6
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
DADA8014-282F-4963-9986-BCFC63188B6F
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 11 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
E8607EB6-0BF5-4218-9C92-8EE0225AA17A
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.88 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. F8A51DB3-7C7F-4902-B159-1D423CDA90B9
AE197D6F-29DB-4952-8FA8-91DB5DCFD553
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
09896AA6-F981-4407-97DA-8004F60E7937
W16X31 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.25 0.00 9.44 57.1044 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
58EADA83-DB44-4FE6-85FC-510747343AEB
W16X31 W21X68 BEAM_TO_BEAM NONE 0 0.00 90.00 -5.25 0.00 2.82 191.34 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 58EADA83-DB44-4FE6-85FC-510747343AEB
08410363-4CB8-4991-8A55-247E3759DB6D
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.46 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 1F600D7F-4C5E-495A-86ED-F28C923A50ED
6D23561F-58EC-4295-BEE5-00A1A2EB6173
W14X53 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 6.98 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
FC07D5E4-4C1C-4879-AD88-0F9340F1CE4E
W18X40 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.13 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 775F59CC-D207-424C-943C-45AD46BDA2C0
1F600D7F-4C5E-495A-86ED-F28C923A50ED
W14X22 W21X44 BEAM_TO_BEAM NONE 0 0.00 83.03 -6.88 0.00 14.17 15 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. 775F59CC-D207-424C-943C-45AD46BDA2C0
3F47254E-E617-4C19-8ADF-CE741A29D5DA
W18X119 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.63 0.00 45.00 63 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. E38F5BF5-B3F9-476A-8BF8-011B1208C40A
5AC22012-EAB4-48C9-BAC5-A63A7755EF44
W21X68 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 5.25 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
D2EF0942-F263-4253-BC4B-B59575638260
W14X90 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections to a girder where there is a column flange above or below are not supported yet. 6815E598-889F-410D-A199-6334C0E62A0F
9D406AB8-1B78-4133-BDDA-799B127C0192
W21X44 W18X40 BEAM_TO_BEAM NONE 0 0.00 82.89 2.75 0.00 26.98 47 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 9D406AB8-1B78-4133-BDDA-799B127C0192
709627D5-9623-4FCF-A0B4-AF1FA3793033
W14X43 W21X44 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 62FDF846-535A-4AA7-8554-D2F2C04F3267
C0F54A76-A2F7-47C9-8320-E638CBB91E0C
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 10.00 30 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 62FDF846-535A-4AA7-8554-D2F2C04F3267
380C0450-E673-4C3A-B6DB-9B8B15560968
HSS16X8X1/2 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.25 0.00 17.50 55.6145 0 0 0 0.00 0.00 0.00 0 0 2284.5 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. 380C0450-E673-4C3A-B6DB-9B8B15560968
061CD475-F454-4C42-AC1E-79DCE10446B7
W14X61 HSS16X8X1/2 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
061CD475-F454-4C42-AC1E-79DCE10446B7
W14X61 W21X68 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
83C2ABD3-24A6-4CEB-B831-12BFF1CB9BB8
W12X16 W21X83 BEAM_TO_BEAM NONE 0 0.00 83.01 -9.38 0.00 9.24 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
W21X83 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.13 0.00 20.00 60 0 0 0 0.00 0.00 0.00 0 0 2032.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. FD3D037D-5494-438B-9070-EDDC0EA5C82B
FEF4C8EC-BDB4-4327-BDFC-291A69AB5C22
W14X61 W21X111 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2032.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
1281E5CB-B4F0-449C-9E64-513FC966FD48
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.63 0.00 20.00 31 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. E8607EB6-0BF5-4218-9C92-8EE0225AA17A
D7D680D6-D0E7-4A17-AB9D-EEE8EB5A95A7
W14X61 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 66445B1E-7A02-42C3-A9DF-234872A5B7DF
45586449-08E6-46AC-9C1F-F1730B8F8C85
W14X53 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
66445B1E-7A02-42C3-A9DF-234872A5B7DF
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
9653A074-7541-48AF-AE0C-04A23F47DA27
W10X12 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.00 20 0 0 0 0.00 0.00 0.00 0 0 2278.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. DD10C239-456B-42DE-8ECB-76ADE840A197
E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
W14X61 W16X26 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. DD10C239-456B-42DE-8ECB-76ADE840A197
C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 19.93 16.6231 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
98550496-1EAE-45E3-877C-94C5CF156DE9
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 98550496-1EAE-45E3-877C-94C5CF156DE9
0693463D-E958-47A2-8A6E-6A157F3D5270
W16X26 W14X22 BEAM_TO_BEAM NONE 0 0.00 -67.00 2.00 0.00 21.65 14 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
5733EEB6-E12F-48BF-8369-B6EFB5E40790
W14X43 W21X62 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
8D62A7F1-4DC9-4CFF-8F89-72AA203C5B98
W14X145 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
W21X44 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 39 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
F16F62A7-7E7D-4653-B4DF-E4926C59E7C1
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 31.21 27 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 9D79DD74-29D9-4233-B923-BC24FA2C5CD3
3058B5D6-FE1D-4DC4-8753-07ED34D79B67
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 248161F1-985E-4AC8-BB3C-80AFE7593D46
9D79DD74-29D9-4233-B923-BC24FA2C5CD3
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 3058B5D6-FE1D-4DC4-8753-07ED34D79B67
55C3B4D4-4080-4C0B-8975-98E30CF1B29E
W21X62 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.13 0.00 45.00 56 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
D3FCA134-870E-489A-85DE-89BC970A0259
W14X61 W21X62 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
3449F51F-9875-41AF-B0EB-CC4113E034DE
W14X61 W21X62 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 56148724-7135-4712-B68F-305F3B27138C
7BF637B5-4B36-482F-AC76-9F1D4103CF01
W14X90 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 56148724-7135-4712-B68F-305F3B27138C
E8A24FF6-D411-44C7-892A-FA1889F00148
W21X48 W21X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.13 0.00 20.00 44 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Filler beam workpoint is not between support end points. 56148724-7135-4712-B68F-305F3B27138C
9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
W21X44 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 39 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Filler beam workpoint is not between support end points. 9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
E565E1A1-4654-4BE3-8633-7DF48C63EF26
W16X36 W21X44 BEAM_TO_BEAM NONE 0 0.00 -88.40 -4.75 0.00 33.80 38 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 33E6BC41-0C99-44B6-B465-0AA2D6135BA6
3058B5D6-FE1D-4DC4-8753-07ED34D79B67
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
33E6BC41-0C99-44B6-B465-0AA2D6135BA6
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
92D20A49-A600-4E40-9E2C-F6632FE8BD3B
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.88 0.00 45.00 47 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
F2043603-D371-4973-9114-1C5BA5270DA0
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. DA24DB18-6A90-4E73-B417-15AFA2D6459C
839A1792-276B-4D50-9709-4BB23AA90A8C
W14X43 W24X94 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
E51E3C2A-5BB4-4822-9DE9-C2A7C008F9F3
W14X61 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. DD10C239-456B-42DE-8ECB-76ADE840A197
99BFD3F8-9C08-4097-818C-EDF0A9F0806F
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. DD10C239-456B-42DE-8ECB-76ADE840A197
FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
HSS16X8X1/2 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.25 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
46022672-A263-41E3-BE1B-5233A95442D7
W14X43 HSS16X8X1/2 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 0169F8F2-6ADA-48AE-8C4C-4FE86A105E05
46022672-A263-41E3-BE1B-5233A95442D7
W14X43 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
D0BF0B8B-C43A-4741-989E-6BB05970F7FB
W14X61 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. 98550496-1EAE-45E3-877C-94C5CF156DE9
FE52CDED-369B-4256-AA0A-3DACCB1205F5
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections to a girder where there is a column flange above or below are not supported yet. D83E7D92-5F8D-4E00-AE97-1C88E941B14D
98550496-1EAE-45E3-877C-94C5CF156DE9
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. FE52CDED-369B-4256-AA0A-3DACCB1205F5
8D380BA7-470A-46EB-AC04-0B346404ABEE
W14X61 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 21.48 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 71DEE630-6CEF-42ED-A93D-8FFD7E27B01A
BCA24E27-99E9-4C19-91AD-8602025D509F
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 1F023FF4-695C-42CC-8A12-C825D216A4C8
28F7B09A-AAF8-4FA1-9B99-E55D7C669C39
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. C733972F-E1F6-4272-A287-DB3F2FACF0E0
C9EEF9BF-E989-4DFC-9F93-C24FA7734139
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.875 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. E8FFA5E5-A849-4BD3-99D1-CE641157E4F4
2A73A730-ED7A-4253-B03D-ECE82218B54D
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.94161 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. 380C0450-E673-4C3A-B6DB-9B8B15560968
12271B2D-328A-4980-9C13-72EC0ED7C824
HSS16X8X1/2 HSS16X8X1/2 BEAM_TO_BEAM HSS 0 0.00 90.00 0.00 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. 12271B2D-328A-4980-9C13-72EC0ED7C824
B702B89D-A7C0-4D3A-937D-BCB51C5B7934
HSS14X14X3/8 HSS16X8X1/2 COLUMN_TO_BEAM BELOW 0 -90.00 -90.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
B702B89D-A7C0-4D3A-937D-BCB51C5B7934
HSS14X14X3/8 W21X68 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 9BD7CF86-7C35-4F19-B138-5F71ED3BEC54
1E02AB57-37E5-4ED0-8607-9482A69F05FB
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.39 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
8BA0FDD2-A9DC-4EBE-A84E-23BB3DACE0E2
HSS5X5X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. AE11B7E1-DD01-4CF9-8590-E0107AD83279
27F45B62-0967-4B30-BEA7-86FB2A0B63B3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.94161 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. AE11B7E1-DD01-4CF9-8590-E0107AD83279
B5C69C86-7BB2-4A34-93BC-8EF507044ECE
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.96401 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. E0B08B4B-BC81-4005-AAC6-417BF00C352B
1A7E56F8-6FF5-4621-B2E4-C14BAD41C75B
HSS6X4X3/8 W21X50 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.47 0 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 1F023FF4-695C-42CC-8A12-C825D216A4C8
7C2ED840-1EDA-4D65-B6AC-2048B239B59A
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. A378805D-EF66-4E95-A394-22742217D921
EF44D347-1114-425F-9294-B21DF9CD3489
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 95EB7118-8314-4E74-B818-CE6EF4153278
0C9E4ABC-4B3D-4057-9A7D-CB892D4350FE
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 95EB7118-8314-4E74-B818-CE6EF4153278
9FA14F1A-28C6-4780-99FE-A91C7DC4968A
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. A378805D-EF66-4E95-A394-22742217D921
72D0F3B9-B576-431E-9986-7C9B789A3E10
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 5BA9D70E-D611-46DB-BFA4-A222377D4379
83422ED1-126B-43BB-8E34-1F4606FEBFFB
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 20.92 0 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. C733972F-E1F6-4272-A287-DB3F2FACF0E0
0DE66CD8-056E-45D6-BB65-15291ECDEAD3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.875 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 71DEE630-6CEF-42ED-A93D-8FFD7E27B01A
A0990116-875E-4BFF-A230-6FB982ADB335
W14X68 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections to a girder where there is a column flange above or below are not supported yet. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
354255C4-13C1-46BD-BA52-8560A1359BA6
W14X145 W18X35 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 6815E598-889F-410D-A199-6334C0E62A0F
59D4C6F3-8A47-4609-99C8-2B08E70B31ED
W14X48 W18X40 COLUMN_TO_BEAM BELOW 0 -90.00 -7.11 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 427C6FEC-A3F4-4B94-AF2F-2036950F72C5
8D0E40CF-D698-4738-BE89-65CC343BF67E
W14X43 W16X26 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. 3E81227F-89E2-48F3-A9E8-76C9CAC23401
427C6FEC-A3F4-4B94-AF2F-2036950F72C5
W16X26 W12X14 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections to a girder where there is a column flange above or below are not supported yet. 9D406AB8-1B78-4133-BDDA-799B127C0192
3E81227F-89E2-48F3-A9E8-76C9CAC23401
W12X14 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -8.75 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
9CEB8268-1533-4B64-8788-FE214DA33696
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 34 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
C276519D-931D-4557-A516-97AAA2C95482
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. C276519D-931D-4557-A516-97AAA2C95482
4326ED42-B1A3-42DD-AB36-B7AC28C3D5EE
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. EB0A5650-5372-4B64-95AC-FC05B4CCD970
61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 36.00 9.20381 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
99BFD3F8-9C08-4097-818C-EDF0A9F0806F
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
40C63F99-248E-48A3-8957-E040456F18F3
W14X43 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 21.43 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 5F3409F2-EEB2-4863-BE3D-F41423B0E21C
40C63F99-248E-48A3-8957-E040456F18F3
W14X43 W21X62 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.43 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 68E06054-293C-4849-BE0D-A5697055AF9F
533D23BF-124A-432B-9A4A-108CBDA05A88
W14X43 W18X119 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
29A4429C-7C11-4369-B150-41A91340B480
W14X43 W18X119 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. D9774C64-813D-425A-921B-5050D603A4BC
932040FE-6BD9-4602-8956-8894D0165AB5
W14X43 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 -7.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. DBBDA364-B5E0-4A93-BBF6-7B4B1998AA26
CF3BF6CE-FA02-4047-B0A3-520C2BABD269
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 5BA9D70E-D611-46DB-BFA4-A222377D4379
62A561CB-EFCE-4140-93FE-BE548C568F08
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 20.92 0 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. DBBDA364-B5E0-4A93-BBF6-7B4B1998AA26
2F5F3FE9-763F-433A-A884-EEE474444560
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.39 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 9BD7CF86-7C35-4F19-B138-5F71ED3BEC54
A2F168E3-D51E-4484-B1CF-CE93B7E3B450
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
8E991592-FBAD-489E-A6E6-610B1365B54A
HSS5X5X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
1884E767-2104-413D-A6D5-E2817A1CBCDA
HSS14X14X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 -90.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. E8FFA5E5-A849-4BD3-99D1-CE641157E4F4
70768AA5-CD06-4FB4-B52E-A002F75353F3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.96401 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
A87D25E9-1CB3-48C8-858C-480496B5824A
W14X43 W16X26 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
427C6FEC-A3F4-4B94-AF2F-2036950F72C5
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 5F3409F2-EEB2-4863-BE3D-F41423B0E21C
C8C2BA86-6C64-46B5-9279-6521E18C5D11
W24X94 W21X62 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 16.60 14 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
499094DD-41A4-4EA3-8B57-D1D407C31029
W14X53 W24X94 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
64E291F4-9FFC-479D-883A-2B6F3CFB9E05
W21X68 W24X94 BEAM_TO_BEAM NONE 0 0.00 68.05 -3.13 0.00 21.56 39 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
93E5BAF9-BF31-489D-B072-86DFC3E13267
W14X22 W24X94 BEAM_TO_BEAM NONE 0 0.00 -90.00 -10.50 0.00 7.85 30 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
17F2540D-9E27-45BD-8D2D-676F5D700302
W16X26 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 35.76 12.3362 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
W21X68 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 5.38 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
3E729E78-C4E4-4E47-BDAA-737205B93C38
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
13699A5D-FF3F-4C95-AD7C-E0A39B386076
W14X90 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. A40D0707-CB63-494F-B78F-83BF153E7098
A3B19E90-7446-4394-A3C4-F37771BD1791
W14X43 W12X16 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
A40D0707-CB63-494F-B78F-83BF153E7098
W12X16 W16X26 BEAM_TO_BEAM NONE 0 0.00 67.00 -3.75 0.00 23.98 8.36555 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
3E729E78-C4E4-4E47-BDAA-737205B93C38
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 -23.00 0.00 0.00 20.00 15 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 67.00 -2.00 0.00 36.00 9.20381 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. DA24DB18-6A90-4E73-B417-15AFA2D6459C
6E4F05C5-C84B-4282-9D3A-759EF54C0C0F
W12X19 W24X94 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. EC9F51C2-9A42-4D6E-B3A7-2573CC3BEB9D
E11A9FA9-4046-4F6F-885B-B84E82038A95
W14X90 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
EC9F51C2-9A42-4D6E-B3A7-2573CC3BEB9D
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.00 0.00 34.21 9.68489 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
349A93AA-A84A-4167-820A-E344A2DBC1F5
W16X31 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1043 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 349A93AA-A84A-4167-820A-E344A2DBC1F5
E04C1F22-7523-4C8C-9792-60EE82E00B47
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 12.55 29.00 8.50024 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. E38F5BF5-B3F9-476A-8BF8-011B1208C40A
9E20047B-C29A-49E9-B3C6-8FC2EF85B368
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
2BD545B9-B4D3-4539-A691-17D35E50301D
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
0169F8F2-6ADA-48AE-8C4C-4FE86A105E05
W21X93 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 45.00 52 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
B19FD047-D193-4F17-BD9A-E647EB2E3A7B
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 0D29E819-F503-405B-B95C-4FF0E5821A33
35B36F33-6288-429B-8D92-DA2A0B197C57
W14X43 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
0D29E819-F503-405B-B95C-4FF0E5821A33
W16X31 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 15 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 15D779B3-01BD-4026-B23A-5946BB50BF7E
5F3409F2-EEB2-4863-BE3D-F41423B0E21C
W21X62 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 5.13 0.00 36.94 42 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 15D779B3-01BD-4026-B23A-5946BB50BF7E
B19FD047-D193-4F17-BD9A-E647EB2E3A7B
W18X35 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 82B6DDE8-5EA9-47A7-99A7-E52B87E0CBF3
09896AA6-F981-4407-97DA-8004F60E7937
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1044 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
330773F5-4848-43C6-825B-2A3F6107354B
W14X90 W12X16 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
W21X68 W12X16 BEAM_TO_BEAM NONE 0 0.00 90.00 9.13 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
6E16102F-7F80-494D-93BE-4F0AC76ECCA0
W16X31 W12X16 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 21.17 25.4609 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 89D99BFB-B6EE-4D8B-8116-1A1BA775D16A
6E16102F-7F80-494D-93BE-4F0AC76ECCA0
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 21.17 25.4609 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 6E16102F-7F80-494D-93BE-4F0AC76ECCA0
213704B6-293E-4CA5-ADD6-B558F50C559D
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 6E16102F-7F80-494D-93BE-4F0AC76ECCA0
E04C1F22-7523-4C8C-9792-60EE82E00B47
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.75 0.00 29.00 8.50024 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
W21X93 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 45.00 44 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
DC9CD579-EADC-4D9B-A308-0777106D1EFF
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 31 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
1F7BFCA6-0252-45BF-85FE-95269A4DED78
W21X68 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.38 0.00 45.00 40 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
DC9CD579-EADC-4D9B-A308-0777106D1EFF
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 30 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
8947A135-68C5-46CC-8E05-B28987D6170A
W14X43 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
W21X55 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.00 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
3B267DA9-DCCA-414C-96DB-D25EBE0A708C
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.94 23 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. E0C6A216-D539-4869-9C0F-BE322A51195F
F7041EBC-0A5F-41C2-A893-054BBEC2EA04
W18X46 W21X68 BEAM_TO_BEAM NONE 0 0.00 74.00 -3.13 0.00 22.70 43 0 0 0 0.00 0.00 0.00 0 0 1849 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 5ACCFAD4-3AF1-423D-B75C-24933259776D
E0C6A216-D539-4869-9C0F-BE322A51195F
W21X68 W21X68 BEAM_SPLICE NONE 0 0.00 -180.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Qnect does not yet support HSS filler beams. FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
12271B2D-328A-4980-9C13-72EC0ED7C824
HSS16X8X1/2 HSS16X8X1/2 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 89D99BFB-B6EE-4D8B-8116-1A1BA775D16A
9E20047B-C29A-49E9-B3C6-8FC2EF85B368
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column to beam connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
0807590A-F1FF-4219-9E8D-5634D9FB6D77
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
D59E77B0-2045-419A-B1D3-BED72A4CFA6A
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 8F7D6983-98F1-42CE-A45B-6297267D17FB
80DF8878-242B-4F70-892F-77645F4FC07A
W14X90 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 8F7D6983-98F1-42CE-A45B-6297267D17FB
D59E77B0-2045-419A-B1D3-BED72A4CFA6A
W12X19 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a beam splice connection. 82B6DDE8-5EA9-47A7-99A7-E52B87E0CBF3
349A93AA-A84A-4167-820A-E344A2DBC1F5
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1043 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a beam splice connection. 349A93AA-A84A-4167-820A-E344A2DBC1F5
8F7D6983-98F1-42CE-A45B-6297267D17FB
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 1.88 0.00 35.67 18.6048 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
9990395D-C5F9-4CA1-8C33-EA8CD33240AF
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1041.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
07F207CA-417E-4698-A4D6-2B2BD28C14F9
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
A1CD8BCC-EE2C-4564-B72F-E5F0082185EA
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
87FF52DD-96F0-4F6A-A339-FED94A5FAFC0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
1474C278-5BCC-4B53-A4F4-54B5E499E9AE
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
72F82F9D-AFEB-4508-BD61-4913D9487AD4
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1036.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
E86CEC60-9811-4F21-8378-1AA264B1D951
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
40BCA70D-9613-449D-A200-39CC88828505
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1039 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA2C79DF-4464-4828-8B5A-DF0586C652DD
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA9B453D-CE7A-4935-AA25-C32EB8CCB2C4
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
E86CEC60-9811-4F21-8378-1AA264B1D951
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
6BA6F088-920D-4379-B9D7-AD918F213074
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1044.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
57578118-5DED-465C-8EB1-C8D1958EA3E8
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1050.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26681301' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
04618F34-6F18-43EC-8179-239A9C337C8E
W18X40 W14X193 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.84 26 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26681300' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
01031F35-4B6F-47FF-B0A6-EF120C111C75
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 1042.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26681299' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
F44BFA89-47BD-4525-8FDA-94984C75BE4D
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 1042.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
08611823-A0DF-4724-B96E-4FC82D2E642A
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
40BCA70D-9613-449D-A200-39CC88828505
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1039 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
4BDBC0DA-5AC0-42CD-8785-4004F4C3BC13
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
DE29FF8E-BF33-4A4A-9626-509B85110A73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
C5555BC7-464A-4206-B4E3-AEB9A0610615
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4 for component '26681254' was found to have been modified since the data was extracted. 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
B9A744CB-CA9B-497A-9DB6-85878E29EC90
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1042.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4 for component '26681253' was found to have been modified since the data was extracted. 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
01031F35-4B6F-47FF-B0A6-EF120C111C75
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 1042.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 50546E67-F121-4E6E-98C4-D115C89553F7 for component '26681252' was found to have been modified since the data was extracted. 50546E67-F121-4E6E-98C4-D115C89553F7
B9A744CB-CA9B-497A-9DB6-85878E29EC90
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1042.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 50546E67-F121-4E6E-98C4-D115C89553F7 for component '26681251' was found to have been modified since the data was extracted. 50546E67-F121-4E6E-98C4-D115C89553F7
33760131-AABD-4CE4-8D56-9B4251752F2D
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
2C703255-B570-490D-AD12-7B5768716A5A
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
68D61397-09E1-4169-88F2-FA7838BB3027
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
4BDBC0DA-5AC0-42CD-8785-4004F4C3BC13
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
4A514482-1250-4A1D-82BB-AB906D16E559
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
7B5D0835-3264-438C-A363-E584CC040CBC
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
BD1608D5-8C87-4301-B0C2-A6C3BDE7EE2B
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
8B94BA7F-178F-428B-A061-0CA609EC4DF0
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
C5555BC7-464A-4206-B4E3-AEB9A0610615
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
D513D20E-A0D4-4979-BEF0-9DA03CA5F2D4
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
EB8F8740-1C62-48B6-9391-56EF77C970A7
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
D513D20E-A0D4-4979-BEF0-9DA03CA5F2D4
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
8B94BA7F-178F-428B-A061-0CA609EC4DF0
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
4A514482-1250-4A1D-82BB-AB906D16E559
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
332A4BDE-4B5B-4DFD-BB8E-A7D5C614EC76
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
C3B67647-C79C-47A0-957D-31D9A00FFE08
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
36938698-4BA9-41BE-917B-A36EB9A0FC7B
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
EB8F8740-1C62-48B6-9391-56EF77C970A7
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C3B67647-C79C-47A0-957D-31D9A00FFE08
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
E402D4C8-8B0E-412D-A2DF-E8234A150806
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
7B5D0835-3264-438C-A363-E584CC040CBC
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
8E939106-3544-4847-A451-02B9FE563093
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
5F45BE64-1227-4A36-ACAF-240C3FCCE685
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
4662964D-09EA-474E-82DF-190E3404786F
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
DE29FF8E-BF33-4A4A-9626-509B85110A73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
BE29BE2E-0573-476B-8EB5-09A2916D5146
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
5F45BE64-1227-4A36-ACAF-240C3FCCE685
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
2FC6C261-A9BB-460C-8276-697979348CBC
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
79E706EA-CF58-4772-9C52-24C59E7AA11F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
FDA425D1-9A5C-4304-BD4B-B83B47B6A6E1
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
4D69B209-DC9D-4C2E-90A3-363A0EAAB9A8
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
B83E4BFD-35BE-4E6D-A243-7DE904AACCD0
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
618B7D73-0831-411D-83B4-6D185E515F74
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
ECC79D6E-8DF8-48F9-960B-DE3BD0B9B10D
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 715 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26681171' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
88FA880F-47B3-4860-9907-05ABD9FEBF31
W18X40 W14X233 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26681170' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
282D77CB-2C17-45B1-A6B4-4C4ACC56802F
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 718.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26681169' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
092961A4-3E92-4DDC-8752-87B121730DF1
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 19.29 25 0 0 0 0.00 0.00 0.00 0 0 718.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
DCC42B0B-8198-48F8-9008-1140575A294A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
5568689A-8E7E-4EFB-B746-91800AF5BBE3
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
4D69B209-DC9D-4C2E-90A3-363A0EAAB9A8
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
90193749-4D48-4485-94A4-712852C1075A
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
E409BE8E-7F0A-4F4E-9E9E-D5C46BA399A3
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
79E706EA-CF58-4772-9C52-24C59E7AA11F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
48F21262-19B0-4C58-B229-37695B5C54A8
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
7C017594-77A8-4254-A474-5466C182C66B
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
B5CEAB43-AD5C-462C-A73B-1CD1C0CF3DB7
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
E4FB8F81-2AEC-4CCE-991C-9E0A5814A3E4
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
CDBC348F-F280-483D-AA9A-21F9BF34D9D7
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26681107' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
W16X26 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 11.53 13 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26681106' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
9A30DC52-488C-497A-A4EA-44FD248621FE
W12X16 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 10.00 25 0 0 0 0.00 0.00 0.00 0 0 708.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26681105' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
44E2EFCE-86D0-4CD9-BAB7-0B0E4D5DA0F4
W18X35 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -84.95 0.00 0.00 35.88 23 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26681104' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
F0CACF5E-AD1B-4C2B-8A54-050BFBF3D6C9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 17.20 30 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD for component '26681100' was found to have been modified since the data was extracted. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
54D006C8-08BB-4B7A-B5D5-2456DC8F05D8
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 718.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD for component '26681099' was found to have been modified since the data was extracted. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
A9B8EA68-5AF3-46A3-8FFC-9154374CE30B
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: E56A7BEB-870C-414D-B0E6-DA41BF1E9951 for component '26681096' was found to have been modified since the data was extracted. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
B8E52704-68D8-4BC8-95F8-346999DD8FB9
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 24.30 30 0 0 0 0.00 0.00 0.00 0 0 718.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: E56A7BEB-870C-414D-B0E6-DA41BF1E9951 for component '26681095' was found to have been modified since the data was extracted. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
092961A4-3E92-4DDC-8752-87B121730DF1
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 19.29 25 0 0 0 0.00 0.00 0.00 0 0 718.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
90193749-4D48-4485-94A4-712852C1075A
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
DCC42B0B-8198-48F8-9008-1140575A294A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
814463BF-E07A-4868-BA19-1AF3BBC0F82A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
F1F2E840-F729-4D5E-88C4-2F02C285D9A9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
814463BF-E07A-4868-BA19-1AF3BBC0F82A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
2FC6C261-A9BB-460C-8276-697979348CBC
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
52F03D7C-F789-4945-A234-8CEE041E5A17
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
ECC79D6E-8DF8-48F9-960B-DE3BD0B9B10D
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 715 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
F1F2E840-F729-4D5E-88C4-2F02C285D9A9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
E409BE8E-7F0A-4F4E-9E9E-D5C46BA399A3
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
F20C520C-6FAB-4611-86E4-E8C30BB2B733
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
E4FB8F81-2AEC-4CCE-991C-9E0A5814A3E4
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26681058' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
AF28B49E-2985-433E-AB32-651A6EAC1B31
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.02 34 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26681057' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
B55504D3-7F37-454C-944C-446549C20C06
W21X93 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26681056' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
5568689A-8E7E-4EFB-B746-91800AF5BBE3
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 23 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26681055' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
B55504D3-7F37-454C-944C-446549C20C06
W21X93 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26681054' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
91FEE975-E115-47E1-97E5-50FC15748BC6
W10X12 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 6.67 20 0 0 0 0.00 0.00 0.00 0 0 706.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26681053' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
FDA425D1-9A5C-4304-BD4B-B83B47B6A6E1
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 18 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26681052' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
0C301115-D48F-46D5-891C-6D76EA4C0FDD
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A4BCA449-3F74-4868-92C4-37314EE32E81
C18CECA7-786E-438A-90F1-3E9D531A96FE
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
10182BFB-3F0E-402E-B372-A4CB2E5E1742
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 27 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
F4EE37B9-E741-4D36-B39B-06EF520F33D4
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
52F03D7C-F789-4945-A234-8CEE041E5A17
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
8A0DC28B-E36F-4C92-9D8F-05A2573685DE
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
513CA458-BCA5-4485-887A-7CCBE0A15528
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 720.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
96E8B22E-A55B-4E49-B1AE-93DBB8E7B139
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 726.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26681036' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
DFCFAD4D-E84E-4798-91A5-8BCD798559AB
W18X35 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -81.40 0.00 0.00 33.69 26 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26681035' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
42EACDBF-A2B9-4FA3-AFA9-CECC8E44C7FE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.35 30 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26681034' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
F0CACF5E-AD1B-4C2B-8A54-050BFBF3D6C9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 17.20 30 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
6D387DF4-1A84-49B7-B50B-FD77E469E6CF
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
F54B8854-C8DD-4C13-8AD5-1335CE677D12
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 877 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
0AA99F9D-AF78-4DD6-8A64-B3B5E44A4B77
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 879.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26681007' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
FB13F20F-A32F-4B79-B4A4-79E655FBC7A9
W18X40 W14X193 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.84 26 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26681006' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
ACF3CB8C-50CB-442A-BAF4-4A404A4686C5
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 880.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26681005' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
4044276B-90AA-40AA-8D6D-AA5C426BF5BB
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 880.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26680955' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
B6CEBF3F-40B5-4BF3-BE1F-4D3F3145D4EF
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 718.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26680954' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
164449FA-183D-4AC4-A037-110A114B7952
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 74.01 0.00 0.00 22.70 29 0 0 0 0.00 0.00 0.00 0 0 717.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26680953' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
30B33508-899D-465B-AE20-12356BE761B1
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.97 25 0 0 0 0.00 0.00 0.00 0 0 718.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9891A6D6-73F2-4A01-84C5-5A080393E4D6 for component '26680943' was found to have been modified since the data was extracted. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
B6CEBF3F-40B5-4BF3-BE1F-4D3F3145D4EF
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 718.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
9D890586-34C2-47C3-8614-76DCB516DB1A
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 717.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
E4680621-D95B-4976-BCAE-FC08E98DE74E
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 712.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: F5FC6427-D2C3-420B-AEED-31A7034FC390 for component '26680940' was found to have been modified since the data was extracted. F5FC6427-D2C3-420B-AEED-31A7034FC390
42EACDBF-A2B9-4FA3-AFA9-CECC8E44C7FE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.35 45 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: F5FC6427-D2C3-420B-AEED-31A7034FC390 for component '26680939' was found to have been modified since the data was extracted. F5FC6427-D2C3-420B-AEED-31A7034FC390
9D890586-34C2-47C3-8614-76DCB516DB1A
W21X55 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 31.06 45 0 0 0 0.00 0.00 0.00 0 0 717.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
44E2EFCE-86D0-4CD9-BAB7-0B0E4D5DA0F4
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
02354002-467C-493B-8F08-6C88474D3AD4
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
EBB3572C-49F2-4487-9934-020C03DB822F
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 50546E67-F121-4E6E-98C4-D115C89553F7 for component '26680919' was found to have been modified since the data was extracted. 50546E67-F121-4E6E-98C4-D115C89553F7
08292F3E-638C-4E81-8DA2-5D77F73BD55F
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 880.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 50546E67-F121-4E6E-98C4-D115C89553F7 for component '26680918' was found to have been modified since the data was extracted. 50546E67-F121-4E6E-98C4-D115C89553F7
9660E3AE-96DC-47B4-AFC0-47107F512C3F
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4 for component '26680917' was found to have been modified since the data was extracted. 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
08292F3E-638C-4E81-8DA2-5D77F73BD55F
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 880.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4 for component '26680916' was found to have been modified since the data was extracted. 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
ACF3CB8C-50CB-442A-BAF4-4A404A4686C5
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 880.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
1C1FC92B-3571-4867-91E1-3AE35F72C25C
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
F54B8854-C8DD-4C13-8AD5-1335CE677D12
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 877 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
691C75C1-2582-401A-AEEE-F15C09A6C35E
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
689ADEB9-9825-4A62-88EE-1A1315909242
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
1F94773B-2930-461F-A854-48D77DA01A32
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
3ED42457-E046-4E6B-AF46-8004D040E5DA
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
1F94773B-2930-461F-A854-48D77DA01A32
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
4DCE8FB6-B3C1-4586-8573-8E3AE1C19FF5
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
6772C9AD-A31C-4F13-BDED-9E3B86D17F45
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
4DCE8FB6-B3C1-4586-8573-8E3AE1C19FF5
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
09BEC59D-D492-43E8-85E0-394F7BEF0944
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
6772C9AD-A31C-4F13-BDED-9E3B86D17F45
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
42013A6D-FA13-4A89-BADC-7FB88D1CC700
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
2E8C7F2A-45BB-41E9-A2EC-A1D470577F0F
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
689ADEB9-9825-4A62-88EE-1A1315909242
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
0822EADF-84F2-4E9F-9DF6-F4CE3511C282
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
6903FA2E-8371-4DFB-9E55-F39121BF277D
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
8D0EE022-267E-493E-AD7B-F3D62C548A88
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
4F863091-9932-455D-B755-9D8FB784721A
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
6903FA2E-8371-4DFB-9E55-F39121BF277D
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
5034D831-8F41-417E-A845-25F84C493354
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DB888ED2-2EFB-4594-B51A-BE66A8A25278
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
206F21FD-019F-4E90-B100-F1A4020AF3B3
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
1C1FC92B-3571-4867-91E1-3AE35F72C25C
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
9ECF74B0-3B1B-4A46-A31F-074BD6CA5067
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3EDF3563-93EB-42E2-94D2-048DCEFD098A
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 882.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
ACEC7EE8-E7E7-4F4D-8481-ED07320975EE
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 888.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
644134AB-98B2-490E-A698-D3D69D9A15E0
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 874.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
08CF93AC-05E4-4744-B7BB-41B07352052B
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
3ED42457-E046-4E6B-AF46-8004D040E5DA
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
38556A05-88D1-49DC-93DC-58ECCDA27F73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
DB58F1F5-9B73-42A2-9855-8519B825AEAC
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
42013A6D-FA13-4A89-BADC-7FB88D1CC700
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
691C75C1-2582-401A-AEEE-F15C09A6C35E
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
38556A05-88D1-49DC-93DC-58ECCDA27F73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
8D0EE022-267E-493E-AD7B-F3D62C548A88
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
6AE98562-7689-4F55-927F-1769383AD9AD
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
5C055762-0D11-4C2D-B0B4-3CF176B40298
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1527.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 429C8C48-CA88-405B-8AF1-B545D954B2AE for component '26680766' was found to have been modified since the data was extracted. 429C8C48-CA88-405B-8AF1-B545D954B2AE
77CF4055-0451-45FD-9CC0-1DA29176ED49
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1528.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 429C8C48-CA88-405B-8AF1-B545D954B2AE for component '26680765' was found to have been modified since the data was extracted. 429C8C48-CA88-405B-8AF1-B545D954B2AE
1831DC83-350E-42A9-B505-0BEC62B4A45C
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 313E3F6D-87A2-4330-8BD4-7291B3E9511D
F476C5A2-1C06-4C32-9622-AA025E32CB44
W18X35 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
02E3C9C6-6632-4F27-B884-583D1882EF33
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
A7C16C77-3A1D-47FC-B2F1-148BA4C6AAF3
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1525 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
600E9556-6A64-4F03-B737-E766786707F8
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
DD9BDCFA-1240-4FFB-980D-63D1972D8F95
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
5AEC3194-1010-410D-AB2B-5F5370F3888B
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
60A11EE5-9F01-40A5-A6E6-6F6C8BC49103
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
99CF7CD4-000F-42F4-92B1-FC7C1F9DD098
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2C2A0152-D6D9-4A67-A13A-A5BA5BD894F3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2C3EADC4-CF75-4C6D-894E-41DE9BE3D333
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
1CD20200-26AF-4DD6-9C56-B4ED2100A5B2
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
909A473B-9768-4743-9EB3-DD31AEC2DBF6
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: EA539FBB-004F-446D-B763-D2D5DAF4CABE for component '26680685' was found to have been modified since the data was extracted. EA539FBB-004F-446D-B763-D2D5DAF4CABE
ED92AD93-6630-4BB6-8214-4A34D4C8804C
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 24.30 30 0 0 0 0.00 0.00 0.00 0 0 1528.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: EA539FBB-004F-446D-B763-D2D5DAF4CABE for component '26680684' was found to have been modified since the data was extracted. EA539FBB-004F-446D-B763-D2D5DAF4CABE
409B96D2-67CA-4464-AD21-C5EE8869E1CF
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 30 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
0B8ED8BF-7302-490B-828A-4FD33A9AA395
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1689.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
3B5CBB2A-756A-4DC4-BFD0-01A234A06FBB
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
D493CF11-869D-4C64-8349-3A093CDF3527
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1687 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C284BE98-8C8B-4F63-A459-B4C32103553D
BBCA9207-8685-48F3-BD48-5586F1327BAE
W14X48 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
B61368C3-F1F0-4877-8A2F-9C1560903460
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
D4CF178C-8391-4B21-849E-53C3C2811D0F
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
A7A435DA-E1FA-430C-A7E0-DC46A2EDD5A6
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
263343D3-EECD-472D-8B1E-BA0725ABB96A
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
E95CC985-766A-40B5-843A-91C246B9ECEA
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1692.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
68374965-673C-4F2A-B6E8-1E2A35BB5D67
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1698.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
7478B226-28CE-49A7-9ABB-1AD84BE3752C
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1684.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
9C094811-32D4-4AC9-8610-0B0ECF2DA51C
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
2ED7D7BE-C726-439C-B383-6161815B50E9
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 429C8C48-CA88-405B-8AF1-B545D954B2AE for component '26680533' was found to have been modified since the data was extracted. 429C8C48-CA88-405B-8AF1-B545D954B2AE
874FA54F-3280-4186-AA16-9582D59838FA
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1690.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 429C8C48-CA88-405B-8AF1-B545D954B2AE for component '26680532' was found to have been modified since the data was extracted. 429C8C48-CA88-405B-8AF1-B545D954B2AE
0F9DCBEE-01ED-4F41-BC54-3891A441925C
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: EA539FBB-004F-446D-B763-D2D5DAF4CABE for component '26680527' was found to have been modified since the data was extracted. EA539FBB-004F-446D-B763-D2D5DAF4CABE
05057867-BEBA-4F94-B638-078BA5AAC564
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 24.30 30 0 0 0 0.00 0.00 0.00 0 0 1690.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
B866C8BC-C813-43DF-8D28-DE1206793453
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
A79EAA08-06A7-49D1-BEB0-F4A692CFCE76
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
3A974128-BAE4-4620-A864-5A5DA17CBDA7
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
A79EAA08-06A7-49D1-BEB0-F4A692CFCE76
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
E37DDECD-720B-417F-995A-9C11964818DF
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
4C830EA6-7678-490A-8B36-438FC2E09D1C
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
B866C8BC-C813-43DF-8D28-DE1206793453
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
EFD9D322-8321-42E0-B05C-213EA2EA5BBB
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
E0FA1338-D96B-44F1-A658-7D769EDC882F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
F1DEBF2C-3B33-4DDC-9D7F-86A562F621A6
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
E0FA1338-D96B-44F1-A658-7D769EDC882F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
DAD17DA8-E0C4-4067-AF7A-93553C415567
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
4C830EA6-7678-490A-8B36-438FC2E09D1C
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
B26A91E2-7FBF-47CD-AC68-46CE305F0411
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
D276D777-F9CF-4B9C-96C1-78318DE09FED
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
B9EA48A0-46B8-4028-AC7F-117DADA7DEF0
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
6D3097C1-575C-4A8F-80A0-E9F3AF2AA0A0
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
EFD9D322-8321-42E0-B05C-213EA2EA5BBB
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
3BE858F1-3ED8-41E9-9E63-53B092C374FF
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
D276D777-F9CF-4B9C-96C1-78318DE09FED
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6D3097C1-575C-4A8F-80A0-E9F3AF2AA0A0
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
3A974128-BAE4-4620-A864-5A5DA17CBDA7
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6533527D-87BB-4684-B4B4-7F283841B16F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
6533527D-87BB-4684-B4B4-7F283841B16F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
82BC3F73-3226-43A7-BF39-2F8A5A8DF305
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1198.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
D0C9055C-C95D-4CF0-A952-EC0F4C860212
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
5E4049D3-8400-49DF-97B9-D447A71A47FE
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
F24D6827-EF28-42CE-8A89-F5B5AA91949D
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
9B1E10B9-490A-455C-8B2D-9D7975A2E924
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
B78071DB-FBFB-4858-A7C0-84C0D2439FF0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
C384AEFB-93B1-4BAF-99FF-9FE8969585A1
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
CBFE8BCC-04AA-4588-A971-BD5A0EA51521
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
5E4049D3-8400-49DF-97B9-D447A71A47FE
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
87FF52DD-96F0-4F6A-A339-FED94A5FAFC0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
CBFE8BCC-04AA-4588-A971-BD5A0EA51521
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
A1CD8BCC-EE2C-4564-B72F-E5F0082185EA
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
65551263-D3C7-4A9C-9051-02E863BBE33E
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
AD7F6766-68F3-4FEE-A40A-ACB2241635FF
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
0CD67DF9-7524-4913-9707-A993AAB38E14
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
D8696BAE-DDE7-4C45-B160-DF771D795EEC
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
D27ED056-4C4D-43FB-8EEA-DC310B5B5DD6
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
55E8770B-B960-4C16-B268-11221343DAD8
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
AD7F6766-68F3-4FEE-A40A-ACB2241635FF
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
645DE082-39CA-4731-A6D4-66FE413595C7
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
07F207CA-417E-4698-A4D6-2B2BD28C14F9
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
F24D6827-EF28-42CE-8A89-F5B5AA91949D
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
D27ED056-4C4D-43FB-8EEA-DC310B5B5DD6
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
96032FED-706D-495B-AF80-D6469A64D0E5
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C0139783-4A96-4DFD-BC58-47B07868F60A
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C384AEFB-93B1-4BAF-99FF-9FE8969585A1
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
B78071DB-FBFB-4858-A7C0-84C0D2439FF0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
19922770-D3D0-4B84-A77E-CD6E4ADBDEBC
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C18CECA7-786E-438A-90F1-3E9D531A96FE
C284BE98-8C8B-4F63-A459-B4C32103553D
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3920436F-0D69-42D9-92ED-5EB2A1854AF2
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
B11ABEDF-B74E-47B4-A3D2-00EB87ED4F40
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
0ED27B40-69EC-49F1-821F-463086065E57
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
9B6CCE28-C3CE-4306-BE2C-583C7A374A28
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
30D80433-5F2B-43A3-BB33-539C9C1B3012
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1206.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1212.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
0ED27B40-69EC-49F1-821F-463086065E57
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
D15610A2-DBEA-43C2-BCC7-DF88E58A1448
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1201 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
4DE834F5-0DB8-40AD-992C-DA6638990EFC
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
D15610A2-DBEA-43C2-BCC7-DF88E58A1448
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1201 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
0E759104-908A-4B1E-BF17-38C4378267ED
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1203.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 50546E67-F121-4E6E-98C4-D115C89553F7 for component '26680305' was found to have been modified since the data was extracted. 50546E67-F121-4E6E-98C4-D115C89553F7
E3FD68E9-8157-459F-8B35-8051D4BB37DE
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1204.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 50546E67-F121-4E6E-98C4-D115C89553F7 for component '26680304' was found to have been modified since the data was extracted. 50546E67-F121-4E6E-98C4-D115C89553F7
B526847D-F8AF-4083-861F-D21F4520226F
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4 for component '26680303' was found to have been modified since the data was extracted. 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
E3FD68E9-8157-459F-8B35-8051D4BB37DE
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1204.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4 for component '26680302' was found to have been modified since the data was extracted. 7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
3A81EDCB-C02D-40E3-84F4-0E73B11AD27F
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 1204.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26680301' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
C74087B6-134F-440E-8599-AD82EFF9BAFC
W18X40 W14X193 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.84 26 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26680300' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
3A81EDCB-C02D-40E3-84F4-0E73B11AD27F
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 1204.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: B4047916-F629-490E-A1C9-F1A1216D9BA0 for component '26680299' was found to have been modified since the data was extracted. B4047916-F629-490E-A1C9-F1A1216D9BA0
2F776F30-8E39-4A68-89C8-1DCDBED42085
W21X111 W14X193 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 1204.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 313E3F6D-87A2-4330-8BD4-7291B3E9511D
087B0D32-CAA8-41A0-844E-8DECB3B64D2D
W18X35 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9FF912D-F57B-4621-AD56-820FFDFF41EB
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
265B3CBE-072B-4CE2-9EE1-FC28AAE074F9
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
D8A4934B-F55F-4590-B143-880EEE11A922
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
06961564-5173-4DBA-B492-336B919CD8AC
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
5EC7EC86-9DDE-43A1-91E4-AE09322B7360
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1368.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C7213124-48AA-40CB-B8DD-61160DF07882
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1374.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
1BE10706-69DF-46B6-A76A-BF37A9E82588
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
2C0FFF3E-B39F-4D78-B522-CBFB10B18124
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
26A03CC8-A1C5-42EA-ACDB-41C953479896
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
1CD20200-26AF-4DD6-9C56-B4ED2100A5B2
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
1BE10706-69DF-46B6-A76A-BF37A9E82588
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
13A4B26E-830E-4BE7-B968-5BB5D175599A
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
600E9556-6A64-4F03-B737-E766786707F8
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
E78330FC-19B4-4101-92FE-E35425AC7D3D
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1522.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
59034CCD-412A-45C4-8B12-024E027CD2E8
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1365.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
65AAB779-19C1-4FB9-BF7C-5FA9B07C72B7
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1360.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
2B42C63E-1F18-4A7E-BB3C-9D526B812C83
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
2C0FFF3E-B39F-4D78-B522-CBFB10B18124
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
60A11EE5-9F01-40A5-A6E6-6F6C8BC49103
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
F6C84A6B-A4B5-4C74-8C90-B67F696BC4F1
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
2B42C63E-1F18-4A7E-BB3C-9D526B812C83
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
F75AA877-EFD5-4760-BF3B-CDB63BF36D84
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
13A4B26E-830E-4BE7-B968-5BB5D175599A
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
F75AA877-EFD5-4760-BF3B-CDB63BF36D84
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
565274B4-2FF2-4D87-B632-1BEC81AE60D8
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
2C2A0152-D6D9-4A67-A13A-A5BA5BD894F3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9B41AB5-9928-4556-B238-0DB97FCBEDA7
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
DB2DCC2D-0928-4A7B-9657-F26B2C0F0C17
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
49CA5CFB-F823-4DB3-9E34-9C81B2DF2602
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
DAB357CC-1145-4228-96A8-B56406947794
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1530.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
9ED7B62F-8CF2-4A54-821D-1C08FC0622BB
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1536.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
125CEAD5-2A48-4C7A-9EEC-3067C05E2FAD
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
5950A269-3C8D-47A4-B6A4-B776976D2A70
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
27C98207-E2E3-420C-808F-1E2C41D23838
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
17DC808C-4200-48A8-BD95-E6D63D750CEE
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
684F750A-1713-4A5B-9C13-67491BF20952
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
F8B7F6EA-09C5-4B44-A782-95698E60E2FE
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: EA539FBB-004F-446D-B763-D2D5DAF4CABE for component '26680127' was found to have been modified since the data was extracted. EA539FBB-004F-446D-B763-D2D5DAF4CABE
26A62879-A444-4A9C-A94B-4F2957A666D9
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 24.30 30 0 0 0 0.00 0.00 0.00 0 0 1366.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: EA539FBB-004F-446D-B763-D2D5DAF4CABE for component '26680126' was found to have been modified since the data was extracted. EA539FBB-004F-446D-B763-D2D5DAF4CABE
1B3E4706-2C36-4249-B693-11E222531C7A
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.84 30 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
049BBF43-0F2F-45D9-AA4C-62D4530A7A96
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
57570467-7F5C-42C0-93AA-58DB1A1E3350
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
F4E64A91-7316-4339-9A7D-A40E2961872D
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
6831B7C4-D1AB-4A2F-A7F3-045968A9502C
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
33758C8D-DEE0-42C7-9857-E163188E4C4F
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
17DC808C-4200-48A8-BD95-E6D63D750CEE
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
307F3923-F3F1-4797-8B0F-9947D954E81D
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
57570467-7F5C-42C0-93AA-58DB1A1E3350
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
2B54F546-F091-4F35-87A6-0C3CD0529A3B
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
4FACBCAB-A75E-4AE3-B242-588EF02286D3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
049BBF43-0F2F-45D9-AA4C-62D4530A7A96
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
5950A269-3C8D-47A4-B6A4-B776976D2A70
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
FD5DED3E-6F8C-421A-98E3-1C285E33FECC
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
CEA25699-3307-4688-9462-42725037FE0C
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
FD5DED3E-6F8C-421A-98E3-1C285E33FECC
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2DC7B671-44FA-4DA2-B22F-ADF1B217F996
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
4FACBCAB-A75E-4AE3-B242-588EF02286D3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
E9680558-D287-4B05-93C0-A88F87DA6E51
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
125CEAD5-2A48-4C7A-9EEC-3067C05E2FAD
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
F4E64A91-7316-4339-9A7D-A40E2961872D
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6831B7C4-D1AB-4A2F-A7F3-045968A9502C
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 429C8C48-CA88-405B-8AF1-B545D954B2AE for component '26680082' was found to have been modified since the data was extracted. 429C8C48-CA88-405B-8AF1-B545D954B2AE
74F7B310-B3DD-45C0-9B72-660A375C49E3
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1366.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 429C8C48-CA88-405B-8AF1-B545D954B2AE for component '26680081' was found to have been modified since the data was extracted. 429C8C48-CA88-405B-8AF1-B545D954B2AE
69A5B6C3-1ED5-4DC7-BE76-4F3B26F6931E
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
612C667E-1F48-4071-9D75-4F984044C791
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
24790D35-0C18-466A-AD1E-08FE9E5C5E73
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1363 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
A0BF4D51-F4D7-4361-A522-B3827E544B24
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 24 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
705D515C-E499-4482-A35F-A4BB13F49404
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
B5D3DC47-51B0-42DC-8E9D-AE215948B0F9
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.87 83.01 0.00 0.00 9.30 25 0 0 0 0.00 0.00 0.00 0 0 6.48013 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
7ED2D326-C623-4555-9189-37E5CB200D8D
W12X14 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 6.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
FDB433B6-6EF3-43B9-964E-D84A8F0AE59A
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 11 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
0126C1D4-74D6-4685-80D8-6DCD6791E415
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
553EACB0-7D39-4917-A543-85C8B8FEC36A
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
99B9CC92-97EC-4D10-8B06-EC68F5EEC225
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
C83F4780-5F40-4B15-8CD5-5A82452C20D9
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.05 30 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
B5DD25C8-2788-4505-A2A6-DD77854C02D6
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 14 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
FDB433B6-6EF3-43B9-964E-D84A8F0AE59A
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 15 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
D6E8D097-7CCD-4AD9-8E4E-BF98E4C3ED73
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.994 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
99B9CC92-97EC-4D10-8B06-EC68F5EEC225
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
0890C31C-0E92-47C3-8678-FCCE88B205BF
W18X143 W14X61 BEAM_TO_COLUMN FLANGE_BOTTOM 0 0.00 90.00 19.50 0.00 32.48 72 0 0 0 0.00 0.00 0.00 0 0 2030.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
DA3A0C2D-E764-4BC9-8723-5B11909E3C86
W18X35 W14X61 BEAM_TO_COLUMN FLANGE_BOTTOM 0 0.00 -90.00 17.75 0.00 32.52 18 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
D6E76792-486E-4F11-A233-E4513053F9FA
W12X14 W14X61 BEAM_TO_COLUMN WEB_BOTTOM 0 0.00 90.00 11.88 0.00 9.95 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
3FB8FB5A-E6E2-4140-824C-055B07B10A46
W14X61 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2010.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 229 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 9DBDF860-DBFF-4712-AC7A-3A30D8948579
CDA74AA3-DF88-4810-8889-35ACF1918E5F
W18X35 W14X176 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
CB690996-6939-487D-B49E-D45538E58682
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
E3DA22D7-6927-4271-B064-7B4BF029577E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
553EACB0-7D39-4917-A543-85C8B8FEC36A
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
EB4B7D4A-C24F-4499-872A-D652A479E978
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 105.651 0 0 0 0.00 0.00 0.00 0 0 16.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
CB690996-6939-487D-B49E-D45538E58682
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
814803E5-FB62-4ADC-97E3-87E82C9C045E
W12X14 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 229 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E314A306-7243-4D8E-B2B6-AAE799C6E321
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E79D86EE-97AC-4B9A-B282-A608B7763E08
W16X26 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
814803E5-FB62-4ADC-97E3-87E82C9C045E
W12X14 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E9B055B5-F871-4E8C-9996-F7E04F034332
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
W24X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 234.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D5B94786-A91C-4967-982E-220EF3465CED
W30X108 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 240.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
A4BCA449-3F74-4868-92C4-37314EE32E81
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
339B6FFC-483E-4D6C-9039-D2E895C8DC9F
W21X44 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.93 38 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
64E291F4-9FFC-479D-883A-2B6F3CFB9E05
W21X68 W14X61 BEAM_TO_COLUMN WEB 0 0.00 68.05 0.00 0.52 21.56 38 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
DB8BBBDA-7B8C-4FA3-AC76-6DF0013F4352
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
1F15AD9A-5A71-4CE6-9828-DA0D947A6915
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
705D515C-E499-4482-A35F-A4BB13F49404
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 24 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
BFF1BB7B-2C4A-4AF2-8E1B-76A4682D9204
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.68 83.02 0.00 0.00 11.73 25 0 0 0 0.00 0.00 0.00 0 0 6.5242 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
DD2ADE8C-7BCB-4062-B7E8-763D1F1AD88E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
20A14B6C-AFC7-478D-A7D0-E12867770854
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
B402A432-EB6B-4DA1-98B3-C02A78CA3B0A
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
3252DA2D-96CB-4031-9D99-543A1C2D59F3
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
670CCB57-4B65-444C-80B2-28AA76336512
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.65 83.01 0.00 0.00 14.19 12 0 0 0 0.00 0.00 0.00 0 0 6.52873 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
0CD686BD-D8D9-4987-A7F0-569583C5C2C8
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 24 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
1F15AD9A-5A71-4CE6-9828-DA0D947A6915
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
4922D3E0-63E3-45DD-BDCD-28F3357D185D
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 44.90 33 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
3425B209-B0D1-430C-862F-53A0F747EF54
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.90 -90.00 0.00 0.00 21.17 22 0 0 0 0.00 0.00 0.00 0 0 12.6105 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
B5DD25C8-2788-4505-A2A6-DD77854C02D6
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
0126C1D4-74D6-4685-80D8-6DCD6791E415
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
94BBF2A4-A4D1-49A6-9406-4254F86A012D
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
E3DA22D7-6927-4271-B064-7B4BF029577E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
D6E8D097-7CCD-4AD9-8E4E-BF98E4C3ED73
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.994 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
EB4B7D4A-C24F-4499-872A-D652A479E978
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 105.651 0 0 0 0.00 0.00 0.00 0 0 16.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
94BBF2A4-A4D1-49A6-9406-4254F86A012D
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
E54E4D50-A406-493F-898E-6B059B28A71C
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
945B9712-14B0-4C6D-8D0E-240621A4E6CF
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
313080E6-FCA6-4F7F-85B0-F1FC944996FC
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
DC6DB2A9-3885-4421-B0E3-E96E06A3292C
W16X26 W14X283 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
AE7BB2C3-935A-48D7-96D5-1121EF0D4258
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
3252DA2D-96CB-4031-9D99-543A1C2D59F3
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
D0336686-216C-4690-AC5E-0E7D950E66F2
W12X14 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
AE7BB2C3-935A-48D7-96D5-1121EF0D4258
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
9AFB54B4-E145-40EC-8DB7-E9729A40D2D0
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
A09FDA1D-56F8-4B6C-8D85-C8ED27DCC97A
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
7866FAFF-8546-4D6D-B0E2-054488B5447E
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
945B9712-14B0-4C6D-8D0E-240621A4E6CF
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
59DACF10-6852-43F9-85B6-6E8CF5997774
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
A53F4FED-4FC1-458C-9DC5-13C1782BF3FB
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 5C925D0A-3A93-4004-AB00-E1CE70D77408 for component '26679651' was found to have been modified since the data was extracted. 5C925D0A-3A93-4004-AB00-E1CE70D77408
615CD836-586C-4899-A8EC-E5CBF071A8C7
W21X93 W14X311 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 5C925D0A-3A93-4004-AB00-E1CE70D77408 for component '26679650' was found to have been modified since the data was extracted. 5C925D0A-3A93-4004-AB00-E1CE70D77408
DA234511-C4DC-4DDB-9A9C-F4731076BE43
W10X12 W14X311 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 6.67 20 0 0 0 0.00 0.00 0.00 0 0 220.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 5C925D0A-3A93-4004-AB00-E1CE70D77408 for component '26679649' was found to have been modified since the data was extracted. 5C925D0A-3A93-4004-AB00-E1CE70D77408
920C707D-B075-49B9-9701-A738BFF18234
W18X40 W14X311 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 18 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 5C925D0A-3A93-4004-AB00-E1CE70D77408 for component '26679648' was found to have been modified since the data was extracted. 5C925D0A-3A93-4004-AB00-E1CE70D77408
C8BD9D39-EDF7-4BDA-98DB-2604F3C94C5F
W12X14 W14X311 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
E8AA279A-91C1-44E3-A531-6BEF522F95C0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
920C707D-B075-49B9-9701-A738BFF18234
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
A53F4FED-4FC1-458C-9DC5-13C1782BF3FB
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
48C381A4-0673-44D1-8533-3BD18B793EC0
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
DD2ADE8C-7BCB-4062-B7E8-763D1F1AD88E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
313080E6-FCA6-4F7F-85B0-F1FC944996FC
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
9AFB54B4-E145-40EC-8DB7-E9729A40D2D0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
E54E4D50-A406-493F-898E-6B059B28A71C
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
20A14B6C-AFC7-478D-A7D0-E12867770854
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
E8AA279A-91C1-44E3-A531-6BEF522F95C0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
28F3829B-C801-4A56-9435-B54D0B4364F4
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
215418CF-5155-4DE7-BF8D-FEA7D331BD5B
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 550.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: F5FC6427-D2C3-420B-AEED-31A7034FC390 for component '26679627' was found to have been modified since the data was extracted. F5FC6427-D2C3-420B-AEED-31A7034FC390
4C4D8D3A-0B13-499C-B4DF-8721CF4E6184
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.35 45 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: F5FC6427-D2C3-420B-AEED-31A7034FC390 for component '26679626' was found to have been modified since the data was extracted. F5FC6427-D2C3-420B-AEED-31A7034FC390
E9AF61A6-5511-42A1-897F-9E557B228C89
W21X55 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 31.06 45 0 0 0 0.00 0.00 0.00 0 0 555.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9891A6D6-73F2-4A01-84C5-5A080393E4D6 for component '26679599' was found to have been modified since the data was extracted. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
3807F1D7-DCB1-4E59-8F42-2E0981134DCE
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 394.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
CD691887-0366-4900-BB82-ED1344C3C500
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 45 0 0 0 0.00 0.00 0.00 0 0 393.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26679597' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
3807F1D7-DCB1-4E59-8F42-2E0981134DCE
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 394.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26679596' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
37BD5DB5-3339-4B09-9847-E411FF2E6E7B
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 74.01 0.00 0.00 22.70 29 0 0 0 0.00 0.00 0.00 0 0 393.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26679595' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
BBA0F4A2-E1BA-4300-90A5-9E75A7901D43
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 26.66 25 0 0 0 0.00 0.00 0.00 0 0 394.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26679591' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
9E74E3C7-1522-4076-9E7A-9297708EBA94
W18X35 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -81.40 0.00 0.00 33.69 26 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26679590' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
4C4D8D3A-0B13-499C-B4DF-8721CF4E6184
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.35 30 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26679589' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
C9BCBC31-621F-4139-967B-E92E9A0515F2
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 17.20 30 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9891A6D6-73F2-4A01-84C5-5A080393E4D6 for component '26679586' was found to have been modified since the data was extracted. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
F3943551-2582-411A-8FF8-4EEF15BB9947
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 556.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
E9AF61A6-5511-42A1-897F-9E557B228C89
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 555.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26679584' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
F3943551-2582-411A-8FF8-4EEF15BB9947
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 556.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26679583' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
70CDD522-30F8-4A4A-B7CC-A59B8387C17B
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 74.01 0.00 0.00 22.70 29 0 0 0 0.00 0.00 0.00 0 0 555.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681 for component '26679582' was found to have been modified since the data was extracted. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
ED82A4E5-60BC-427C-BC29-0C649D64344E
W21X83 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.97 25 0 0 0 0.00 0.00 0.00 0 0 556.125 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
E1A24D1C-C617-446C-814B-5DAA9723899B
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
6D7A7A62-7283-4A9F-AA7F-272B51C22F76
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 553 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
51722E2E-DE77-4900-A816-96B0B6630476
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
6D7A7A62-7283-4A9F-AA7F-272B51C22F76
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 553 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
B97C2FC4-AEBC-4586-BFD2-2838ABD4CE22
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
E9A564FA-1924-4FF2-911F-C01F6D2D7BFA
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
51722E2E-DE77-4900-A816-96B0B6630476
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
493FF51E-9946-49B3-AE0A-6B3E3359B27C
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
C467921C-493F-45AD-9E62-A315333FD341
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 558.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
2DFE2DB3-B007-4F74-9E03-FAD3F1C597E8
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 564.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26679552' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
C4FE5277-D46A-455C-A9D4-3C829E641B63
W18X40 W14X233 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26679551' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
F03C9AD1-A1F1-4562-B7DD-440CB1A3CA7C
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 556.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26679550' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
E4EBB496-ACC6-4146-95E1-152F28574155
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 19.29 25 0 0 0 0.00 0.00 0.00 0 0 556.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
4508A29D-E08E-4FE2-BDFE-001B670608E9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
F5B0BE9B-BA87-4BC0-AD40-3D5DF02994A8
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
C1BF1EE8-BA5D-4DFA-A1E8-AADDF0163B02
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: E56A7BEB-870C-414D-B0E6-DA41BF1E9951 for component '26679532' was found to have been modified since the data was extracted. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
E708889D-D00E-41E8-9900-6ED122E8D60D
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 24.30 30 0 0 0 0.00 0.00 0.00 0 0 556.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: E56A7BEB-870C-414D-B0E6-DA41BF1E9951 for component '26679531' was found to have been modified since the data was extracted. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
E4EBB496-ACC6-4146-95E1-152F28574155
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 19.29 25 0 0 0 0.00 0.00 0.00 0 0 556.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD for component '26679528' was found to have been modified since the data was extracted. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
A7DBB5C6-EB9C-436D-AAF4-205A7F0F221D
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 556.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD for component '26679527' was found to have been modified since the data was extracted. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
7EE3C853-3A9C-4EC0-ACE3-46017EB65F8B
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
DB60F5ED-7F55-4689-9444-86D24B90E382
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679473' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
7DB6F78D-008F-4DC2-BC7A-72F695E45D03
W16X26 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 11.53 13 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679472' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
B9F16E64-E8B9-4DB4-8743-58E60A513A32
W12X16 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 10.00 25 0 0 0 0.00 0.00 0.00 0 0 546.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679471' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
DB60F5ED-7F55-4689-9444-86D24B90E382
W18X35 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -84.95 0.00 0.00 35.88 23 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679470' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
C9BCBC31-621F-4139-967B-E92E9A0515F2
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 17.20 30 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
3BBA3389-445C-43F3-AF4A-1585B2DFB030
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
142FEC85-4328-46DC-9110-E0FC51D7A18C
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
7320BF9A-8B9F-4B33-827E-49AFC1FFF44E
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
C1BF1EE8-BA5D-4DFA-A1E8-AADDF0163B02
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
F3AB266F-C75E-4888-B28D-4216A7ED2309
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
7320BF9A-8B9F-4B33-827E-49AFC1FFF44E
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
8809F9F8-675B-48A4-B63B-4061C523CCAE
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
483414A3-6E05-4E69-9401-F9A00FE1A469
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
A4B93EE8-1839-4C1C-A119-DD5B38B9010B
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
CD6957AC-0223-4962-94D8-DFB3E815DFB0
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
EF2D951C-8656-44CA-9BB3-4967F028741A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
6D45C4D1-4942-43F4-BBB8-19F1F5C7A6B7
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
73E43823-B9B5-46C0-85C0-8DF1C8F77851
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
4508A29D-E08E-4FE2-BDFE-001B670608E9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
8809F9F8-675B-48A4-B63B-4061C523CCAE
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
CD6957AC-0223-4962-94D8-DFB3E815DFB0
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
A1EA0FCD-E4CD-4D62-B31F-82D016C7D8FB
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26679441' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
722ADE7E-3247-40CE-A1E7-603FF0F031A9
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.02 34 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26679440' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
72D8C652-06C1-4AA6-BDC9-B915F514A9A1
W21X93 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26679439' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
703BBCFC-E599-4FC0-807B-0FF980FC2EAC
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 23 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
F5B0BE9B-BA87-4BC0-AD40-3D5DF02994A8
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
703BBCFC-E599-4FC0-807B-0FF980FC2EAC
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
6D45C4D1-4942-43F4-BBB8-19F1F5C7A6B7
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
7DB6F78D-008F-4DC2-BC7A-72F695E45D03
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
C59419E9-8972-4BF5-9C20-03A9CDDC97B5
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
A4B93EE8-1839-4C1C-A119-DD5B38B9010B
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
1076266C-185D-4A02-8800-814B68103DA1
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
C59419E9-8972-4BF5-9C20-03A9CDDC97B5
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
F3AB266F-C75E-4888-B28D-4216A7ED2309
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679424' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
72D8C652-06C1-4AA6-BDC9-B915F514A9A1
W21X93 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679423' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
F5630E69-46F7-4EB9-B4C8-1B542D149DDB
W10X12 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 6.67 20 0 0 0 0.00 0.00 0.00 0 0 544.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679422' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
EF2D951C-8656-44CA-9BB3-4967F028741A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 18 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679421' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
5AB53F54-0C75-4EE0-A9AF-0F2060C83A46
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. D2EF0942-F263-4253-BC4B-B59575638260
97E1E225-1274-49B4-96F0-9C15B10FE79A
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 12.29 53.9937 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. D2EF0942-F263-4253-BC4B-B59575638260
9A311228-BADA-4939-BE09-4284DC537648
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
1D0C6816-70F2-4F04-821A-B92F7C1533F8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
2BFAFBEA-D909-48E2-B6C0-B42141CA56D8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
34DCD9A0-605E-45AD-A374-12FB713BAE3D
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
AA7E27DF-A8A1-445A-8B8A-CC454324696A
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
4AE76E9F-B103-46B2-97C1-87B7FB7EE2B8
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
4026F438-CC44-469E-AC07-AFC814A0CC6A
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
16925C51-1F48-41C3-9177-57A81D862BB3
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
B96F4850-C700-4F58-8D68-715FFB63113B
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.38 56.2751 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
9943EA03-024C-4CF4-A4F3-7F3562E0AD59
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
29A1B8BA-6027-4464-B136-C7B5AA2E4B6D
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
2BFAFBEA-D909-48E2-B6C0-B42141CA56D8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. 8947A135-68C5-46CC-8E05-B28987D6170A
AC5F84E0-62FB-4AE2-A46C-C7BA4A157CF6
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. DBCF94F7-3931-4CEE-AAD5-853E22487073
F16F62A7-7E7D-4653-B4DF-E4926C59E7C1
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
5B977253-D4F8-49D0-8B37-9DF50097A4EB
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
6C7A6345-CDE3-4275-986F-8707EC66583B
W16X31 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 56.7286 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
W16X31 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
18F3B61B-8D5A-4B6C-9C3F-FC3CDE294C18
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 213704B6-293E-4CA5-ADD6-B558F50C559D
271D2626-0320-4503-970C-4CDC8E455B81
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 21 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 330773F5-4848-43C6-825B-2A3F6107354B
4DB142DD-A279-41FA-8D8F-CF728D3ECCA5
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
25257CB7-B2D7-454C-B13E-0901FEDC12CB
W18X60 W14X61 BEAM_TO_COLUMN WEB 0 0.00 68.05 0.00 0.52 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1849.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
6D3D51F9-DBF5-4F75-AD74-88267A6C1C0D
W18X40 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
678C216D-A746-442C-A380-918D283211AB
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
4026F438-CC44-469E-AC07-AFC814A0CC6A
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
F8BFFA22-B903-4889-B2FF-9C6639EDAB40
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
564E280D-FEBE-4696-A186-76C3576D57AE
W18X40 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
CA56BEEF-CF7E-434A-A0F0-B2490071D5AA
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
16925C51-1F48-41C3-9177-57A81D862BB3
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
BDD81669-5227-4716-9701-F44DD84165A4
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
756CC3BE-1916-4639-9DFD-4E355FC13213
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. E7058D14-9D97-4EDD-A51C-89B97DE7273B
00ABD163-DF19-4235-84A3-3A45A12E2153
W12X16 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. E7058D14-9D97-4EDD-A51C-89B97DE7273B
704847F5-1E77-4AC8-81D5-37A5BB35BFE0
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -84.95 0.00 0.00 36.00 42 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
CDDD3D90-928C-4BB1-8EA9-5393C4086352
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
FCE74F5C-7E95-4F46-9C0E-0F0DD1E95B00
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
55785F59-9B60-49F3-B58C-30AA03B68B3D
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.66 15 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
BDD81669-5227-4716-9701-F44DD84165A4
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. 35B36F33-6288-429B-8D92-DA2A0B197C57
E5AF0CBE-0F33-41FC-8FF4-51D22C9E505C
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. 35B36F33-6288-429B-8D92-DA2A0B197C57
96C1C0AD-8B52-4BAC-8C4E-CD714FBFCC6F
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 14 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
D59B5E8B-B476-4D2D-92F1-8EA3E96CD6B4
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 8.76 25 0 0 0 0.00 0.00 0.00 0 0 1842.87 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
FCE74F5C-7E95-4F46-9C0E-0F0DD1E95B00
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
9B554201-4E20-41FB-9C03-B67659B5C4CA
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.142 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
A9FD66AF-1B8B-40FB-B3B4-3A8974D6E447
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.44 139.595 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
9B554201-4E20-41FB-9C03-B67659B5C4CA
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.142 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
756CC3BE-1916-4639-9DFD-4E355FC13213
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
F8BFFA22-B903-4889-B2FF-9C6639EDAB40
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
AEAF474C-C465-4353-8B72-079B44AF3416
W18X40 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.06 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
D600274F-5111-48FD-BE56-C6FCF27566B2
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.38 170.326 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
D600274F-5111-48FD-BE56-C6FCF27566B2
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.38 170.326 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
A9FD66AF-1B8B-40FB-B3B4-3A8974D6E447
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.44 139.595 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
B96F4850-C700-4F58-8D68-715FFB63113B
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.38 15 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: E56A7BEB-870C-414D-B0E6-DA41BF1E9951 for component '26679212' was found to have been modified since the data was extracted. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
7E587808-E7B6-4607-B0FC-CC61FE983BDC
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 394.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: E56A7BEB-870C-414D-B0E6-DA41BF1E9951 for component '26679211' was found to have been modified since the data was extracted. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
9A708F2B-FE8E-4EF7-AC3D-E5FB7E83FDBA
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 394.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD for component '26679210' was found to have been modified since the data was extracted. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
DD758878-9BC3-42CF-9224-446656915689
W21X111 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 394.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD for component '26679209' was found to have been modified since the data was extracted. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
9D920AD2-2BF5-49F4-B51C-921AD1612188
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
48910073-C648-4C79-9F0E-CDEB6DCCD3A4
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26679186' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
2BB4F8F6-BB2F-4124-8F8A-976A8E921E34
W18X40 W14X233 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26679185' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
109601B0-2600-4186-908F-D241F1499191
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 394.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: D87A76C1-2CE9-4AA4-9592-65AAD8975AE0 for component '26679184' was found to have been modified since the data was extracted. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
9A708F2B-FE8E-4EF7-AC3D-E5FB7E83FDBA
W21X111 W14X233 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 394.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679176' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
1FA52551-429C-4FE3-9ADE-6103A6ADD729
W16X26 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 12.29 13 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679175' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
80BE5222-EFF7-4E30-8ECB-ABC634EA1EC0
W12X16 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679174' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
9C13A6B6-FE45-4DB6-844F-777976510FE2
W18X35 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -84.95 0.00 0.00 36.00 23 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 52A60369-0465-47E3-AB4C-9C78FEE3FF19 for component '26679173' was found to have been modified since the data was extracted. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
A838D770-3B52-41B9-AF78-5B9ECD734C3C
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 17.96 30 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
BBBCBDC5-670D-4FB4-9FBF-08475A340BD4
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 14 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
1D961F96-411A-4727-87BD-7D8A18A1F63F
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
B1FDCED3-92AA-43EB-A47C-440F2C29E99A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 18 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
44F4ECEB-4019-4CCF-9644-99195C7DBF03
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.08 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
1FA52551-429C-4FE3-9ADE-6103A6ADD729
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 12.29 15 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
AC391EC5-1AE1-47CE-93D8-EC753652C5C2
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
1D0C6816-70F2-4F04-821A-B92F7C1533F8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
22CDA226-78CF-4C8F-8DB6-D4D678B63B83
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 28 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
6F37001C-CC35-4905-9DB9-73EA829D95F5
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
0BED20DE-5349-42DC-8FE3-2865DBD90D9B
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.856 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.08 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
37B7C198-D6FE-43A0-A5A8-4A56219C4E40
W21X68 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1852.12 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
76D141C1-ECEE-4788-8726-50C2028CC89C
W18X40 W14X68 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
82621609-0930-4A7A-90E7-335A0781A457
HSS6X6X1/4 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 6.00 0.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. DBCF94F7-3931-4CEE-AAD5-853E22487073
239B7ACC-6EA7-4D43-AE1B-50EE332512E3
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 30 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
EF123453-B334-4C60-9DE6-59AB3F1B3CBF
W16X31 W14X342 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 226.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. 351414C5-D457-4592-97B4-84B572A89BDF
C6BD7B0E-FCD8-4225-B515-5F0C0B67C7E8
W21X55 W14X257 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 231.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
F7E75267-5AAE-4903-9D0D-8A6597D9DEAF
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 23 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 15 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.856 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
22CDA226-78CF-4C8F-8DB6-D4D678B63B83
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 29 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
34F8A10A-2A9F-47CF-B528-26A7ECB83C95
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 12.38 16 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
CCC0A360-B70F-43D5-BA9A-8E41DBF25414
W18X40 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 36.90 23 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
F52BD167-B6EE-414B-BE1C-48DE68B38C89
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
349CC7F8-F40C-4448-816B-00D5C6524398
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
837EBA43-8547-4950-875A-672030161388
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
9C13A6B6-FE45-4DB6-844F-777976510FE2
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 36.00 25 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26679060' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
EA08F33B-9E35-4B9B-BAB4-16324EE91021
W18X35 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -81.40 0.00 0.00 33.80 26 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26679059' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
58E25113-4ECB-4F03-A096-8328C1869859
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 21.13 45 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 7A54241B-B68E-4262-8210-0BF51F369A96 for component '26679058' was found to have been modified since the data was extracted. 7A54241B-B68E-4262-8210-0BF51F369A96
A838D770-3B52-41B9-AF78-5B9ECD734C3C
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 17.96 30 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
9943EA03-024C-4CF4-A4F3-7F3562E0AD59
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
54EFA1F9-4760-40FC-9B6A-73D0BAACE27A
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
76D141C1-ECEE-4788-8726-50C2028CC89C
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Framing condition is not yet supported by Qnect. 4E860B32-D2BC-496D-820D-93AC7D54BF55
C5DFCC2A-AB41-4AE6-BA45-244A2DC38D64
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26679045' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
1A8BCCA0-999C-40A3-ACA5-EE97216A8BFC
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.13 34 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26679044' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
5BC0F009-8178-45A7-B4D4-663CFA94CB76
W21X93 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 9CA600FE-0339-4342-8695-B6231F25261A for component '26679043' was found to have been modified since the data was extracted. 9CA600FE-0339-4342-8695-B6231F25261A
F7E75267-5AAE-4903-9D0D-8A6597D9DEAF
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 30 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679038' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
5BC0F009-8178-45A7-B4D4-663CFA94CB76
W21X93 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679037' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
7D57EC9B-391D-47F2-BA1C-A876DFAA3A52
W10X12 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 6.67 20 0 0 0 0.00 0.00 0.00 0 0 382.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679036' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
B1FDCED3-92AA-43EB-A47C-440F2C29E99A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: 0BE130D6-D18E-4612-A1E3-F919413279E7 for component '26679035' was found to have been modified since the data was extracted. 0BE130D6-D18E-4612-A1E3-F919413279E7
A9552FA0-B9B4-4E1A-BD10-EDD5742104D8
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
4897A67D-6F4F-4B35-B20A-B62C996F935F
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 388.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: F5FC6427-D2C3-420B-AEED-31A7034FC390 for component '26679029' was found to have been modified since the data was extracted. F5FC6427-D2C3-420B-AEED-31A7034FC390
58E25113-4ECB-4F03-A096-8328C1869859
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 21.13 30 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 The main beam with GUID: F5FC6427-D2C3-420B-AEED-31A7034FC390 for component '26679028' was found to have been modified since the data was extracted. F5FC6427-D2C3-420B-AEED-31A7034FC390
CD691887-0366-4900-BB82-ED1344C3C500
W21X55 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 393.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
CFDFBFD6-6E56-4709-B762-C20275E05F4D
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 79332908-E18B-4B89-A777-5FB4F6F3EF4C
61C6EF8F-F70D-4A29-A6B5-CE6413D750E5
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. ED470781-19F2-4212-B5DF-A6C96B2CBECD
FA2B20A3-4E75-4131-91A7-A614CFDFC746
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
F5FC6427-D2C3-420B-AEED-31A7034FC390
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. BE86D4E7-2CA5-4CB6-9431-C640068DA113
9891A6D6-73F2-4A01-84C5-5A080393E4D6
W14X211 W14X132 COLUMN_SPLICE NONE 0 -90.00 -0.20 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. FE5E2D5C-1417-4F24-9C81-A9255AA51F04
BCAB2633-C665-4DE9-B005-3F8AC0C1711F
W14X120 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 58B83107-5F20-447B-BEB8-A86F72651EE8
BCAB2633-C665-4DE9-B005-3F8AC0C1711F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5C931518-5A05-44EF-A718-E925BB7B94B1
A5437CD8-CE09-438A-A04C-FB59A8C75582
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 18F297E5-76DA-4E32-B991-C804795ED9DF
8915B579-96F9-4355-B4DD-930B01D8E275
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D4A1D721-263B-4B57-A711-206DD3636F2B
C3B6AB56-9E79-4303-AA53-4BED52DCD9E7
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 976194EC-3885-4F9C-8AD2-F926CF6886B0
C3B6AB56-9E79-4303-AA53-4BED52DCD9E7
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 94ECA3BE-EB62-4102-ACA2-674291E7218F
1DEA353D-033A-46DA-BEBE-A85844DA8E76
W14X120 W14X99 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
1DEA353D-033A-46DA-BEBE-A85844DA8E76
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8A9EFCA4-743F-4278-AE8F-610C35E3BED7
D5088096-F760-49AD-915F-741618902EA1
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 7D86E4D7-F48D-456E-AED4-F1499B20B2A0
A9108DB3-8258-4090-BDB0-524D8A7E9B2E
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 198AB2FC-84F3-46CF-9FED-891A7AA29A3B
A9108DB3-8258-4090-BDB0-524D8A7E9B2E
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. F3EDEC65-A90D-4898-A5D1-046B4CFDF563
68BE7F80-CC6D-4762-8DE0-8BEFE27DDAC1
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 3A559CBD-55AD-48E6-A670-10E89C408100
67A81924-72A4-43E9-B3A6-775B5F8AD939
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0BE130D6-D18E-4612-A1E3-F919413279E7
F9375DBA-442E-4B6E-A6D3-D93EB86939C4
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4CCC0250-FFF9-4AF5-8ADB-A75B2E1DB6C3
3698A971-46FC-45EC-B1A8-738CD75AD4EA
W14X257 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4FEA724E-F0C3-4ACA-AFD8-137B8083615C
9D887600-96CA-43B3-8049-3885ED21ED88
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 04DAC6B5-7CAF-4DCF-B790-81EB699E3D41
9D887600-96CA-43B3-8049-3885ED21ED88
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A94E9FCD-F10C-4D9A-A3D4-F02118D4E31A
1FD7B2FE-F5B1-4F0E-859E-61529BE79B2D
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. DE3AE352-A80E-4E1B-B863-3E4F52C83D1D
7A54241B-B68E-4262-8210-0BF51F369A96
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 459BBA95-146B-4DE4-A455-A3A8868F8746
B842C0CA-3A81-4DE0-B3D7-4D6797A042E3
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E1AA0701-83E0-4233-A3D9-53AC4118EBEF
B842C0CA-3A81-4DE0-B3D7-4D6797A042E3
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 9DBDF860-DBFF-4712-AC7A-3A30D8948579
30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 199D1626-4144-4159-A452-3F754AC2FDBD
54AD2023-4C50-4297-B4DF-563A9E989945
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 254E104A-3A1C-4C1A-9853-5744B3552047
31F45CAB-2F14-49FB-ACB6-F07F723118E1
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A60F7B4B-4394-4A19-AA71-DC997EA1EA03
31F45CAB-2F14-49FB-ACB6-F07F723118E1
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. FBDD1DE5-2076-499D-89BE-EF02E3288EE7
4D858208-2A09-4220-BD30-DA2C2FEAB613
W14X90 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 22.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
509F58E7-4085-4E46-9D52-3A072858BDD4
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 7CC96676-4A04-4BE6-B285-A3C9C388FA7F
3F046788-938E-4777-9214-19960D7B760D
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
E0D13FA7-A11F-413F-B5FD-B0545E2B2238
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 1868988C-8768-4AB5-91F9-4C00E69AA95B
F5FFA8C1-21B4-4522-9E3C-33D2A82A168D
W14X99 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 9E5D1E92-A781-4F41-92D7-CCA344D03054
F5FFA8C1-21B4-4522-9E3C-33D2A82A168D
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 2308FF66-29E7-4677-95FC-42AB59DCB43A
766D3CAE-807B-4731-9946-E94B317FDEB7
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 25DDB5D1-4BAC-400F-9D61-C93C00725C38
04E9A7D2-F801-4C42-9930-95E386919649
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5748D66D-3604-46A6-9B2D-C17F09765DEB
6B12E975-80E0-47C2-9110-05B3C2D34B65
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B608D27E-FA9A-40A5-8E55-290C103F50A9
6B12E975-80E0-47C2-9110-05B3C2D34B65
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. 256EEFF9-D368-46E3-86F4-5760B6CE745A
D5B94786-A91C-4967-982E-220EF3465CED
W30X108 W14X176 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 44.92 41 0 0 0 0.00 0.00 0.00 0 0 240.625 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 256EEFF9-D368-46E3-86F4-5760B6CE745A
E0D13FA7-A11F-413F-B5FD-B0545E2B2238
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. EBFF3E23-0757-417D-BE1E-C3ACE8309E71
FCF3AA38-817B-4829-B781-E965BEE60434
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
48EE061A-7EB8-4AA0-B548-FBEF06C6141F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 36B0F1CB-615F-47C7-AB19-E1A13B93CF5B
B9FEAE65-02C3-4DEA-96B1-8A1214E30635
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 9DFB3A01-1130-41C7-82E4-33B818916AD2
87E53653-BDD3-4B75-A233-9DB3B3149B1D
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E4FE6769-C272-4974-8777-AA845DD7091E
D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A254393B-C4CA-46A8-BE5A-5DA128358058
D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
33E416D9-5637-4A34-8A4E-F9A73FEFE321
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
917863AE-38CE-4B33-AEDF-2CC85843B14F
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 2D511FE8-D6A2-4A4C-9F32-F054BB297AEF
9CA600FE-0339-4342-8695-B6231F25261A
W14X211 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
B366A726-300A-4677-B914-2FEC6C93CBB6
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5982A642-8B41-4653-A458-5D49468A0CBA
52A60369-0465-47E3-AB4C-9C78FEE3FF19
W14X211 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
B6696E9B-03DD-4B45-BE1C-79AB81558C51
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0DC49D64-D312-4295-980E-8186405BADF1
6546C29A-342F-41CF-A35B-B0B8A8121786
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
33E416D9-5637-4A34-8A4E-F9A73FEFE321
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
917863AE-38CE-4B33-AEDF-2CC85843B14F
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 1AA81CB9-0E1C-48F4-9936-67143001393A
97E0D34E-2FC7-4F4B-82C9-61BAB429A9E5
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E82B6EA4-9DFE-47FF-B9D0-F16534E8AFDF
79332908-E18B-4B89-A777-5FB4F6F3EF4C
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
234B93AF-4538-475D-9E47-9CC39023D2EB
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D138E37E-1C12-4A9C-BDAC-499BE81AAD51
1FD7B2FE-F5B1-4F0E-859E-61529BE79B2D
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C29CC7BE-FEA7-4F7F-BB3A-2FA142502627
A60F7B4B-4394-4A19-AA71-DC997EA1EA03
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. EDFEBF8B-4EF8-4ED0-9ABB-8ADB5B5AAA66
2D511FE8-D6A2-4A4C-9F32-F054BB297AEF
W14X311 W14X370 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 48.2499 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0BE130D6-D18E-4612-A1E3-F919413279E7
5C925D0A-3A93-4004-AB00-E1CE70D77408
W14X311 W14X211 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 264.004 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5C0B86DC-D2F2-4DD2-AD23-303D10C3F2D2
5C925D0A-3A93-4004-AB00-E1CE70D77408
W14X311 W14X342 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 48.2504 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E05842BC-DDE3-467F-B92A-D2C54AD3EA95
D0BF0B8B-C43A-4741-989E-6BB05970F7FB
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. EA19C6D6-2E82-4892-B19C-54412AF51462
499094DD-41A4-4EA3-8B57-D1D407C31029
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B1CEBEA6-756E-4E0F-8182-2CCAF74CF5D7
6BBACA91-E210-4AD8-B97D-3AA96A9E7C5C
W14X90 W14X145 COLUMN_SPLICE NONE 0 90.00 0.13 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 849D18B6-F17A-437D-81B4-ECB9779C307A
B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
94ECA3BE-EB62-4102-ACA2-674291E7218F
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 25BA3283-EA02-4EFC-ACC6-499E0E2B7005
21F19F0B-25B6-4426-831E-9221191F7162
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5B3C998D-633E-447A-8436-E91E75DD52F0
0A0DF5C0-DE73-42DD-82F9-860DF3D4D4DB
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 804F6CE5-8C92-4234-A4A8-EE007080E0D5
014E5A3F-A64E-4D67-837C-F7685A5B6952
W14X257 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4D1C1EC7-81D8-43C9-BD46-45F1D0E4AA02
E56A7BEB-870C-414D-B0E6-DA41BF1E9951
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.56 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 2052876E-1823-4CF9-A5A1-E235327D49D1
3A559CBD-55AD-48E6-A670-10E89C408100
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 718E8E4E-23D8-4490-A309-35C41B5857A0
A47F26D3-3A1D-47DD-A0ED-05FF144987F1
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 2637778C-DE1B-48B7-9307-B6293C398AE8
274315DF-2A98-467B-9E3F-3340BD4F59F4
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
B5A12E3D-7B9B-4962-8D6B-10C2212F9F5B
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 39.25 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8672619A-330F-427F-B90E-D5FA7749380E
0A4413E4-EEA3-4095-B9FE-32B9E56B12F5
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 1EE71A45-4E74-4978-9FDB-1DF8F3919990
A0B18C57-F5A1-4D6F-8553-695CDB252E2A
W14X61 W14X48 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 51414106-205D-4331-85F6-80A08C0EB129
A0B18C57-F5A1-4D6F-8553-695CDB252E2A
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
8CA384CD-63A7-45E9-999F-804A4789C52D
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0F146864-E5A0-42D6-9916-0AA6FCC7B460
3B4917E8-C019-4738-83DF-DF3E853F06F5
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8F270805-1B17-4B64-A29F-CF9790DB0E5C
C9F26F38-EC3D-4EFF-9674-BD58106FA0E1
W14X257 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A3B9DA33-3DBF-4B64-A3F5-1E976DA661A1
F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 014E5A3F-A64E-4D67-837C-F7685A5B6952
2467842A-34B5-4239-88D0-08878BDBDFB3
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 36.69 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B5A502CD-C6CF-4863-865A-5F9F287F09C6
53853856-6604-43D0-A41A-01558C77B81D
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 99293E55-552F-458D-BE0D-8AEF4F12BA9B
04DAC6B5-7CAF-4DCF-B790-81EB699E3D41
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0A0DF5C0-DE73-42DD-82F9-860DF3D4D4DB
18CD6EE1-AE5C-4C60-933F-92FCA78A859C
W14X53 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 11A61282-48D3-436E-848D-14A7DCACA19E
FE5E2D5C-1417-4F24-9C81-A9255AA51F04
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B5BE23C0-4522-4BDB-8E47-0F43244B58D0
4BCA48E0-FE5F-48A2-AB7B-D6AE926C4201
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 66FFFA38-CAF9-4665-B00F-A08260F332DF
E823BBFD-103C-4562-8321-E61691DA5016
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 39.25 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
AA759B66-B163-41C5-8DDF-AE56C1F84BD1
W14X257 W14X233 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 37.13 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 274315DF-2A98-467B-9E3F-3340BD4F59F4
728BCB88-307A-4127-B12C-009280BAC82D
W14X90 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 857B257E-6DED-42D3-A72C-4697CA4480AF
6E7617B0-54CC-45C4-853A-1F013E64C550
W14X61 W14X43 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 1868988C-8768-4AB5-91F9-4C00E69AA95B
6E7617B0-54CC-45C4-853A-1F013E64C550
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 85D8F200-BC22-4D70-A06F-09BDA98BBB38
9A43B315-F54F-4EE0-819F-F5748C979535
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C29CC7BE-FEA7-4F7F-BB3A-2FA142502627
2ECEC8F6-06D2-496F-8E27-AFEF34276840
W14X43 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 6F5B61CE-BF3C-4ED1-A8D2-1CF234A78487
6D23561F-58EC-4295-BEE5-00A1A2EB6173
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A94E9FCD-F10C-4D9A-A3D4-F02118D4E31A
A651599F-786B-4CBE-BF42-8E36DB79C3AD
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A37ED7B7-1F1E-4221-854A-22E084052C34
213704B6-293E-4CA5-ADD6-B558F50C559D
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
2BAE0A0B-E0B3-4569-B1DD-6E9E654A6B62
W14X120 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
W30X108 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 44.92 41 0 0 0 0.00 0.00 0.00 0 0 1212.63 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. DAA426C2-C841-4BA6-A704-EFEF817CC8DB
22FCAB24-283B-4790-85CF-D3E541B41664
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 134936D7-07A4-41B1-A8DE-EF7052CB2656
313E3F6D-87A2-4330-8BD4-7291B3E9511D
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 36.06 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5ECE6F2E-78AD-4838-9911-EFB264999596
E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
W14X120 W14X90 COLUMN_SPLICE NONE 0 -90.00 -0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. BE86D4E7-2CA5-4CB6-9431-C640068DA113
E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. DE3AE352-A80E-4E1B-B863-3E4F52C83D1D
776B310A-DBC0-419D-97AF-AAB6EE882274
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0D102D6C-E337-4D1D-A0C6-DF1CEEEFE55F
0DDE526F-4027-4C3D-9971-C7C84A4DF35C
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5748D66D-3604-46A6-9B2D-C17F09765DEB
4905A174-F477-4655-A0E4-D1EEB324BD23
W14X120 W14X120 COLUMN_SPLICE NONE 0 90.00 1.42 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A825CA09-646F-4F0E-A88D-C195109686C6
CDE31233-C3C7-4CBC-8918-8C0842DF2791
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D4A1D721-263B-4B57-A711-206DD3636F2B
C685F2B8-A6FF-4398-9B6E-7A877FF10113
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 7D86E4D7-F48D-456E-AED4-F1499B20B2A0
38EDDDC4-866F-44CE-BD8E-AAB3CFF6FFE7
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 975BA93D-8B91-4FAC-8FD1-22145813F256
DBC72FA1-D71C-4823-9A42-17862FEC23B2
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0EDEBE74-842C-4C52-804E-B50CC340296B
9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. F9375DBA-442E-4B6E-A6D3-D93EB86939C4
E168056A-8C92-4709-BDE8-4979BA5C6259
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
96B87704-8949-45CC-B092-EB20FB25B31F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 3EF528DA-76E8-4B14-B1E3-696A796126E6
8152E62A-47CB-479D-A4C7-ECCF842B45EA
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 1EE71A45-4E74-4978-9FDB-1DF8F3919990
68AF7010-8250-4FCA-9003-31E8DD0E88C2
W14X43 W14X48 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 18CD6EE1-AE5C-4C60-933F-92FCA78A859C
D7D8F5C3-F5CD-4EBA-9149-3201EBD95C77
W14X53 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 11A61282-48D3-436E-848D-14A7DCACA19E
9CE6EB0B-EAF3-4FF6-873D-BD8DB74FD3B6
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 2637778C-DE1B-48B7-9307-B6293C398AE8
ADFE58A3-0F4A-44FC-B5FF-98E8488A18CD
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. F9F6C52F-4EDB-46B7-A491-6CDF3350ECC9
B76C4CD9-E923-4CA3-B6DF-58C8DF0EABF7
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E4FE6769-C272-4974-8777-AA845DD7091E
E02CA80D-FC59-4556-B8EE-65046563BC1A
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 66FFFA38-CAF9-4665-B00F-A08260F332DF
ABEE8C90-15B1-496B-A85C-EE3B3CDCBCE1
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 749.754 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0BE172C5-6C31-4CAD-98FC-BEAF6FEE878D
BCA24E27-99E9-4C19-91AD-8602025D509F
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.78 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B9FEAE65-02C3-4DEA-96B1-8A1214E30635
7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 746.243 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 1E08BF51-F015-4461-8A0E-C73E08553BCE
41CD1199-5009-48D1-A5A3-FF28C3976D73
W14X109 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4D272FF9-FA56-4468-89E4-F6FA5735A05B
AE197D6F-29DB-4952-8FA8-91DB5DCFD553
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 90.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.17 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4D5B338E-7968-48D1-9BDB-20093C0CF8B0
28C5BA0D-415B-4012-BCAB-FC953FEB85E0
W14X145 W14X193 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1233.13 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C6FC0258-DCB5-4EBD-B503-598DCEEDA2A9
4E860B32-D2BC-496D-820D-93AC7D54BF55
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0DDE526F-4027-4C3D-9971-C7C84A4DF35C
4B975AA9-C7BE-4936-BCCE-89148831E8CB
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 89.41 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 234B93AF-4538-475D-9E47-9CC39023D2EB
0807590A-F1FF-4219-9E8D-5634D9FB6D77
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E168056A-8C92-4709-BDE8-4979BA5C6259
330773F5-4848-43C6-825B-2A3F6107354B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2263.27 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
90D3759D-A468-44EC-8E1E-D8C401E416DB
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
D2EF0942-F263-4253-BC4B-B59575638260
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B76C4CD9-E923-4CA3-B6DF-58C8DF0EABF7
E7058D14-9D97-4EDD-A51C-89B97DE7273B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8152E62A-47CB-479D-A4C7-ECCF842B45EA
13699A5D-FF3F-4C95-AD7C-E0A39B386076
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 96B87704-8949-45CC-B092-EB20FB25B31F
E11A9FA9-4046-4F6F-885B-B84E82038A95
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E02CA80D-FC59-4556-B8EE-65046563BC1A
80DF8878-242B-4F70-892F-77645F4FC07A
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6B7D2987-C9E2-4534-BA41-E614B5EB444E
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 16108B12-3ED5-4562-B5B1-03AAD09FC446
ED50100C-D93B-43EB-972A-70EDBA07BF0E
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. CF07F7C4-B4D1-4144-B718-102215DF7786
64AE8F49-4E1E-4611-939D-C22BF7153D67
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. CDE31233-C3C7-4CBC-8918-8C0842DF2791
EFDE2B89-981B-433F-8CD6-17ED3BF4C148
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 38EDDDC4-866F-44CE-BD8E-AAB3CFF6FFE7
06A762CD-6FFA-4D78-8266-515E368F9689
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 456239D1-6988-418B-9D36-C38E6C17CA05
3449F51F-9875-41AF-B0EB-CC4113E034DE
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 429C8C48-CA88-405B-8AF1-B545D954B2AE
A0990116-875E-4BFF-A230-6FB982ADB335
W14X68 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 519FDEFE-13BD-46F9-8644-7D891121E73C
3FB8FB5A-E6E2-4140-824C-055B07B10A46
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E9CBDE30-BE05-4801-8593-128620AE5C7D
354255C4-13C1-46BD-BA52-8560A1359BA6
W14X145 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D2CDAB23-BFC1-4CA4-8410-378E31F3A209
59D4C6F3-8A47-4609-99C8-2B08E70B31ED
W14X48 W14X48 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A2915901-C53B-4A9A-B9DE-9F1FCF4D4C9E
8D0E40CF-D698-4738-BE89-65CC343BF67E
W14X43 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 035ED350-53E8-4774-BDA6-DA87F9D1E2EB
7A54241B-B68E-4262-8210-0BF51F369A96
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.949 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 318A24E1-4A86-4E34-BD86-6ABA04648AAB
4326ED42-B1A3-42DD-AB36-B7AC28C3D5EE
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 13C6FBA8-D028-4B31-9D3F-5D111A5CD0F0
79FD091A-B1CE-4014-A0A4-6E3A91F6AB14
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 8.40 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
9258B322-7F52-4655-AECB-8BBBCB754CF5
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.16 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1229.52 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 9258B322-7F52-4655-AECB-8BBBCB754CF5
4D272FF9-FA56-4468-89E4-F6FA5735A05B
W14X132 W14X193 COLUMN_SPLICE NONE 0 90.00 90.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.5 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
DBCF94F7-3931-4CEE-AAD5-853E22487073
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4905A174-F477-4655-A0E4-D1EEB324BD23
4E134221-1035-49CA-B35E-A781B5D4DEBA
W14X109 W14X120 COLUMN_SPLICE NONE 0 90.00 1.05 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1723.34 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. DA9F25BC-167E-4DE7-A9FE-0BDC46482C0F
8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.009 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
96FEE1F7-7165-4EFA-8E9F-895881561ACC
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 748.774 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 351414C5-D457-4592-97B4-84B572A89BDF
9891A6D6-73F2-4A01-84C5-5A080393E4D6
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 265.021 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
F5FC6427-D2C3-420B-AEED-31A7034FC390
W14X211 W14X342 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 263.483 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 68AF7010-8250-4FCA-9003-31E8DD0E88C2
6183D7E5-CFCA-4136-ACC8-792EC36CB012
W14X43 W14X43 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 36.68 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A37ED7B7-1F1E-4221-854A-22E084052C34
4A851DC9-81A8-430C-9E92-B0040852819A
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. FA2B20A3-4E75-4131-91A7-A614CFDFC746
4A851DC9-81A8-430C-9E92-B0040852819A
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D5088096-F760-49AD-915F-741618902EA1
687731D8-D93F-4369-A84B-AE8EC61D855A
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A5437CD8-CE09-438A-A04C-FB59A8C75582
A825CA09-646F-4F0E-A88D-C195109686C6
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 456239D1-6988-418B-9D36-C38E6C17CA05
E9E2186B-1328-44FC-A23E-06A54FBF638C
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 3F046788-938E-4777-9214-19960D7B760D
E9E2186B-1328-44FC-A23E-06A54FBF638C
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0BE172C5-6C31-4CAD-98FC-BEAF6FEE878D
7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
W14X193 W14X132 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Part of group with Not connected due to being a column splice connection. 0A4413E4-EEA3-4095-B9FE-32B9E56B12F5
B4047916-F629-490E-A1C9-F1A1216D9BA0
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1235.99 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 16108B12-3ED5-4562-B5B1-03AAD09FC446
B4047916-F629-490E-A1C9-F1A1216D9BA0
W14X193 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C4492C55-333F-4524-A162-75AAC54BCC30
47A1B78B-9A15-4D5D-A8C0-15E1ABEF088B
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 3B4917E8-C019-4738-83DF-DF3E853F06F5
47A1B78B-9A15-4D5D-A8C0-15E1ABEF088B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A3B9DA33-3DBF-4B64-A3F5-1E976DA661A1
3C3C0857-2A00-4ACE-94D3-67DC25F096E2
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8915B579-96F9-4355-B4DD-930B01D8E275
3C3C0857-2A00-4ACE-94D3-67DC25F096E2
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E05842BC-DDE3-467F-B92A-D2C54AD3EA95
D462CB20-218C-41E3-A4FF-E9488A8B1861
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A47F26D3-3A1D-47DD-A0ED-05FF144987F1
D462CB20-218C-41E3-A4FF-E9488A8B1861
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. FCF3AA38-817B-4829-B781-E965BEE60434
4C2D5349-D1BF-44CB-B18B-E237F9E8ED9C
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 608A8D89-92CE-420D-A377-B0B0A969C19D
13C6FBA8-D028-4B31-9D3F-5D111A5CD0F0
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D2064BCF-9BD5-46A1-85D5-AEED10AE8551
A4B7B146-0337-4286-B35F-D8B15F1A4FDB
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 608A8D89-92CE-420D-A377-B0B0A969C19D
6DA25684-81FD-4DB7-9AE4-ABA3CB9A9A40
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. CFD14E8A-055D-48E7-AEF8-7CEAC63E3845
6DA25684-81FD-4DB7-9AE4-ABA3CB9A9A40
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4BCA48E0-FE5F-48A2-AB7B-D6AE926C4201
DAA426C2-C841-4BA6-A704-EFEF817CC8DB
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 0DDEE9E7-03E6-4812-A4C1-F06AC8876D53
9070ACE5-AF7E-4667-9DBD-8AB7C8365DD9
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 766D3CAE-807B-4731-9946-E94B317FDEB7
9070ACE5-AF7E-4667-9DBD-8AB7C8365DD9
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 96D43969-72D6-48D4-A185-6FA61BE85F1F
B4010245-3B7C-4CAA-95ED-A836EF7C3344
W14X90 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
F9F6C52F-4EDB-46B7-A491-6CDF3350ECC9
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 318A24E1-4A86-4E34-BD86-6ABA04648AAB
4EEFEF1C-2E0E-497B-9EC2-97EC40BEC890
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 68BE7F80-CC6D-4762-8DE0-8BEFE27DDAC1
4EEFEF1C-2E0E-497B-9EC2-97EC40BEC890
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. F3004609-63D0-420E-B92C-2AEA3D319B66
113ADEAB-1E0C-4E18-83F3-F64DD28473FF
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 8CA384CD-63A7-45E9-999F-804A4789C52D
113ADEAB-1E0C-4E18-83F3-F64DD28473FF
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 9CA600FE-0339-4342-8695-B6231F25261A
3EF528DA-76E8-4B14-B1E3-696A796126E6
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
31137C4F-3F63-438D-AFDB-7950376A8126
W14X53 W14X53 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B366A726-300A-4677-B914-2FEC6C93CBB6
31137C4F-3F63-438D-AFDB-7950376A8126
W14X53 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. EA539FBB-004F-446D-B763-D2D5DAF4CABE
ABEE8C90-15B1-496B-A85C-EE3B3CDCBCE1
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1235.51 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 509F58E7-4085-4E46-9D52-3A072858BDD4
B4010245-3B7C-4CAA-95ED-A836EF7C3344
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 97E0D34E-2FC7-4F4B-82C9-61BAB429A9E5
5DD876A1-A3FF-4464-8BA9-041F810834A8
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. EA19C6D6-2E82-4892-B19C-54412AF51462
695DEE27-D1D4-4359-BA69-F51FC052A6A5
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
695DEE27-D1D4-4359-BA69-F51FC052A6A5
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. FC9AE33D-E8B2-4209-B8FB-2CDA0A905896
CEA25DD3-355C-4167-9323-9C662177C0D1
W14X68 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 54AD2023-4C50-4297-B4DF-563A9E989945
CEA25DD3-355C-4167-9323-9C662177C0D1
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 697AF9C6-D06C-4821-B156-FA00822F4358
9BF69AC7-B5FC-4B4C-98C5-4CAF68B9C641
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C9F26F38-EC3D-4EFF-9674-BD58106FA0E1
9BF69AC7-B5FC-4B4C-98C5-4CAF68B9C641
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
134936D7-07A4-41B1-A8DE-EF7052CB2656
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 429C8C48-CA88-405B-8AF1-B545D954B2AE
50546E67-F121-4E6E-98C4-D115C89553F7
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A4B7B146-0337-4286-B35F-D8B15F1A4FDB
0D102D6C-E337-4D1D-A0C6-DF1CEEEFE55F
W14X132 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. BFEE8ADB-BB96-4E92-BBE8-B52C6A6B5ED4
E9CBDE30-BE05-4801-8593-128620AE5C7D
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 4C2D5349-D1BF-44CB-B18B-E237F9E8ED9C
F8936F8C-437A-4661-AF27-2EAC8E077DFB
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. FC9AE33D-E8B2-4209-B8FB-2CDA0A905896
7AF1A487-25FD-474C-ACFA-2872A3AE369A
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. F3004609-63D0-420E-B92C-2AEA3D319B66
08410363-4CB8-4991-8A55-247E3759DB6D
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.46 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
35B36F33-6288-429B-8D92-DA2A0B197C57
W14X43 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 67A81924-72A4-43E9-B3A6-775B5F8AD939
C6FC0258-DCB5-4EBD-B503-598DCEEDA2A9
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 61C6EF8F-F70D-4A29-A6B5-CE6413D750E5
CF07F7C4-B4D1-4144-B718-102215DF7786
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 3698A971-46FC-45EC-B1A8-738CD75AD4EA
BFEE8ADB-BB96-4E92-BBE8-B52C6A6B5ED4
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
50546E67-F121-4E6E-98C4-D115C89553F7
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 519FDEFE-13BD-46F9-8644-7D891121E73C
3E7509DC-FDAC-4C5E-921A-3222F6C2680E
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 21F19F0B-25B6-4426-831E-9221191F7162
3E7509DC-FDAC-4C5E-921A-3222F6C2680E
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 87E53653-BDD3-4B75-A233-9DB3B3149B1D
975BA93D-8B91-4FAC-8FD1-22145813F256
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. E1AA0701-83E0-4233-A3D9-53AC4118EBEF
D14C1B40-3446-429D-9383-FD0C2F23B815
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 687731D8-D93F-4369-A84B-AE8EC61D855A
85D8F200-BC22-4D70-A06F-09BDA98BBB38
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 804F6CE5-8C92-4234-A4A8-EE007080E0D5
47A6DB92-BBD5-4DE0-AF61-41DE5780F226
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
0EDEBE74-842C-4C52-804E-B50CC340296B
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 6F5B61CE-BF3C-4ED1-A8D2-1CF234A78487
5DD876A1-A3FF-4464-8BA9-041F810834A8
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B5A502CD-C6CF-4863-865A-5F9F287F09C6
AF8300FF-515D-4DFA-A6AC-B8B2971656AB
W14X61 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. A2915901-C53B-4A9A-B9DE-9F1FCF4D4C9E
1763B868-4EC6-46BA-A989-914FD8B07FEF
W14X61 W14X53 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. FBDD1DE5-2076-499D-89BE-EF02E3288EE7
1763B868-4EC6-46BA-A989-914FD8B07FEF
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. B6696E9B-03DD-4B45-BE1C-79AB81558C51
DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 6546C29A-342F-41CF-A35B-B0B8A8121786
A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 1E08BF51-F015-4461-8A0E-C73E08553BCE
71FC28AB-78D1-4BED-9262-C73D09A3E8F2
W14X120 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. 04E9A7D2-F801-4C42-9930-95E386919649
71FC28AB-78D1-4BED-9262-C73D09A3E8F2
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
BL 9-17-18 2018-09-17 04:14:25 Not connected due to being a column splice connection. D2CDAB23-BFC1-4CA4-8410-378E31F3A209
AF8300FF-515D-4DFA-A6AC-B8B2971656AB
W14X61 W14X48 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Supported connection type not found 58B5EDAA-0000-0E5C-3134-383833313837
58B5EDAA-0000-0EB6-3134-383833313837
W14X22 W40X149 BEAM_TO_BEAM NONE 0 0.00 85.00 -7.50 0.00 16.86 15 0 0 0 0.00 0.00 0.00 0 0 6.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Supported connection type not found 58B5EDAA-0000-0E5C-3134-383833313837
58B5EDAA-0000-0EAC-3134-383833313837
W14X22 W40X149 BEAM_TO_BEAM NONE 0 0.00 85.00 -7.50 0.00 15.99 15 0 0 0 0.00 0.00 0.00 0 0 6.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Supported connection type not found 58B5EDAA-0000-0E93-3134-383833313837
58B5EDAA-0000-1907-3134-383833323037
W16X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 9.34 55 0 0 0 0.00 0.00 0.00 0 0 -0.75 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Supported connection type not found 58B5EDAA-0000-0E93-3134-383833313837
58B5EDAA-0000-0ECA-3134-383833313837
W16X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 9.34 55 0 0 0 0.00 0.00 0.00 0 0 -0.75 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Not connected due to being a column to beam connection. 58B5EDAA-0000-0E75-3134-383833313837
58B5EDAA-0000-0F65-3134-383833313837
W14X61 W40X149 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 14.46 0 0 0 0 0.00 0.00 0.00 0 0 6.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Not connected due to being a column to beam connection. 58B5EDAA-0000-0E5C-3134-383833313837
58B5EDAA-0000-0F60-3134-383833313837
W14X61 W40X149 COLUMN_TO_BEAM ABOVE 0 90.00 -5.00 0.00 0.00 17.67 0 0 0 0 0.00 0.00 0.00 0 0 14 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Not connected due to being a column to beam connection. 58B5EDAA-0000-0E98-3134-383833313837
58B5EDAA-0000-0EDE-3134-383833313837
HSS8X8X1/2 W24X55 COLUMN_TO_BEAM BELOW 1 -90.00 90.00 0.00 0.00 11.83 0 0 0 0 0.00 0.00 0.00 0 0 3.90988 A992-->A992
A500-GR.B-->A500-GR.B
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E52-3134-383833313837
58B5EDAA-0000-0E5C-3134-383833313837
W40X149 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 32.50 30 0 0 0 0.00 0.00 0.00 0 0 14 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Load computed with UDL is too high. 58B5EDAA-0000-0E52-3134-383833313837
58B5EDAA-0000-0E57-3134-383833313837
W16X40 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 3.08 236.188 0 0 0 0.00 0.00 0.00 0 0 6.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E52-3134-383833313837
58B5EDAA-0000-0E43-3134-383833313837
W27X84 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 10.02 60 0 0 0 0.00 0.00 0.00 0 0 14 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E52-3134-383833313837
58B5EDAA-0000-0E34-3134-383833313837
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 15.06 50 0 0 0 0.00 0.00 0.00 0 0 6.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E2A-3134-383833313837
58B5EDAA-0000-0E75-3134-383833313837
W40X149 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 30.00 55 0 0 0 0.00 0.00 0.00 0 0 6.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Load computed with UDL is too high. 58B5EDAA-0000-0E2A-3134-383833313837
58B5EDAA-0000-0E39-3134-383833313837
W16X40 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 3.00 243.059 0 0 0 0.00 0.00 0.00 0 0 1 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E2A-3134-383833313837
58B5EDAA-0000-0E34-3134-383833313837
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -85.00 0.00 0.00 15.06 50 0 0 0 0.00 0.00 0.00 0 0 6.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E2A-3134-383833313837
58B5EDAA-0000-0E2F-3134-383833313837
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 85.00 0.00 0.00 5.02 50 0 0 0 0.00 0.00 0.00 0 0 1 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E3E-3134-383833313837
58B5EDAA-0000-0E4D-3134-383833313837
W24X55 W14X90 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 -90.00 -2.00 0.00 16.38 25 0 0 0 0.00 0.00 25.00 0 0 14 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Load computed with UDL is too high. 58B5EDAA-0000-0E3E-3134-383833313837
58B5EDAA-0000-0E48-3134-383833313837
W24X55 W14X90 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 -90.00 -2.00 0.00 3.08 433.691 0 0 0 0.00 0.00 0.00 0 0 14 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Load computed with UDL is too high. 58B5EDAA-0000-0E3E-3134-383833313837
58B5EDAA-0000-0E43-3134-383833313837
W27X84 W14X90 BEAM_TO_COLUMN WEB_TOP 0 0.00 -90.00 -2.00 0.00 10.02 60 0 0 0 0.00 0.00 0.00 0 0 14 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F47-3134-383833313837
58B5EDAA-0000-0F42-3134-383833313837
W24X76 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 15.06 35 0 0 0 0.00 0.00 0.00 0 0 -0.75 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F47-3134-383833313837
58B5EDAA-0000-0F3D-3134-383833313837
W24X76 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.06 35 0 0 0 0.00 0.00 200.00 0 0 -0.75 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F38-3134-383833313837
58B5EDAA-0000-0F4C-3134-383833313837
W16X40 W14X68 BEAM_TO_COLUMN WEB 0 0.00 84.98 0.00 0.00 6.58 25 0 0 0 0.00 0.00 200.00 0 0 -0.75 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F38-3134-383833313837
58B5EDAA-0000-0F3D-3134-383833313837
W24X76 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 15.06 35 0 0 0 0.00 0.00 200.00 0 0 -0.75 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F38-3134-383833313837
58B5EDAA-0000-0E89-3134-383833313837
W40X149 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.06 125 0 0 0 0.00 0.00 0.00 0 0 -0.75 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F1F-3134-383833313837
58B5EDAA-0000-0F24-3134-383833313837
W24X55 W14X61 BEAM_TO_COLUMN WEB_TOP 0 0.00 -90.00 -2.00 0.00 16.13 25 0 0 0 0.00 0.00 25.00 0 0 9.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F1F-3134-383833313837
58B5EDAA-0000-0F15-3134-383833313837
W40X167 W14X61 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 90.00 -7.50 0.00 12.87 150 0 0 0 0.00 0.00 0.00 0 0 4 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F1A-3134-383833313837
58B5EDAA-0000-0F24-3134-383833313837
W24X55 W10X49 BEAM_TO_COLUMN WEB_TOP 0 0.00 -90.00 -6.50 0.00 16.13 25 0 0 0 0.00 0.00 25.00 0 0 9.5 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F1A-3134-383833313837
58B5EDAA-0000-0EC5-3134-383833313837
W16X26 W10X49 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 -90.00 -6.00 0.00 10.02 25 0 0 0 0.00 0.00 0.00 0 0 10 A992-->A992
A992-->A992
2D Map1 2018-09-04 14:28:21 Part of group with Moments were turned off on the Minimum job Requirements page. 58B5EDAA-0000-0F1A-3134-383833313837
58B5EDAA-0000-0E4D-3134-383833313837
W24X55 W10X49 BEAM_TO_COLUMN WEB_TOP 0 0.00 -90.00 -2.00 0.00 16.38 25 0 0 0 0.00 0.00 25.00 0 0 14 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
01C64280-8BAA-4E7A-82AF-5966A61F003C
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
BE2F0B52-28FF-4142-B5BD-CDD8126F7653
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
2D9130AD-4510-44A0-801A-A9B40200F63F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
C97A5DFC-F1A6-40D5-88FE-41A41A19BE96
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6B3D27A1-140A-4C85-8EB0-D3E348B70ADE
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 110FDB7D-E948-4EE0-A8DB-5F78B2E4CEB9
C645ACDF-CBF4-49CA-BDDB-73A50A41CA39
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 44.98 33 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found CE568E02-A0A7-472A-8E17-8219D9C19567
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 0C608DA6-3310-40FE-BE53-8DAA2337F78A
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6443C939-BA0F-4583-AD17-6DF35322A218
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
AFFBBDDE-73B9-4003-8175-6176D0CB34F8
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
2D Map 2018-09-04 12:23:21 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
8CBAB442-DBF1-4C66-B53B-4FFA6E0280BA
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
2D Map 2018-09-04 12:23:21 Qnect does not yet support HSS filler beams. 4504EDC8-3A09-4215-9314-EAB179B09449
1745BC85-9DE7-4880-85C8-592FA4BB0EDB
HSS16X8X1/2 HSS16X8X1/2 BEAM_TO_BEAM HSS 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 233.042 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
2D Map 2018-09-04 12:23:21 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
1BD0A2F8-FBB7-4BDB-935A-7802F28440AF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
2D Map 2018-09-04 12:23:21 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
F3FAB671-F5DC-4165-8300-1875CBC0E5D8
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
2D Map 2018-09-04 12:23:21 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
0A840E7D-FE17-48F0-853B-F0354F51F022
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 37.00 20 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
8C8E4204-FD56-4C17-A310-8FC4B169C161
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
71FDDDA4-89E1-445C-99A7-F0FBA6F6B2EE
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
859C0BFC-B315-4D57-9424-90E381D489C0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 19 0 0 0 0.00 0.00 0.00 0 0 386.5 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
CD691887-0366-4900-BB82-ED1344C3C500
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 45 0 0 0 0.00 0.00 0.00 0 0 393.5 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
48910073-C648-4C79-9F0E-CDEB6DCCD3A4
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
4897A67D-6F4F-4B35-B20A-B62C996F935F
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 388.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
9C13A6B6-FE45-4DB6-844F-777976510FE2
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 36.00 25 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
CFDFBFD6-6E56-4709-B762-C20275E05F4D
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
F7E75267-5AAE-4903-9D0D-8A6597D9DEAF
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 23 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
837EBA43-8547-4950-875A-672030161388
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
B1FDCED3-92AA-43EB-A47C-440F2C29E99A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 18 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
44F4ECEB-4019-4CCF-9644-99195C7DBF03
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
BBBCBDC5-670D-4FB4-9FBF-08475A340BD4
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 14 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
1D961F96-411A-4727-87BD-7D8A18A1F63F
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
349CC7F8-F40C-4448-816B-00D5C6524398
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 15 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.856 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.856 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.08 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.08 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
1FA52551-429C-4FE3-9ADE-6103A6ADD729
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 12.29 15 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
2D Map 2018-09-04 12:23:21 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
AC391EC5-1AE1-47CE-93D8-EC753652C5C2
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
E3455F56-6C77-441E-9E49-B0B502610F16
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 63CBDC7A-526B-403B-86DB-4C0079A350C7
C0868018-EAD8-495C-93DD-349011F247FB
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 717.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 63CBDC7A-526B-403B-86DB-4C0079A350C7
89910F0B-27B8-4202-AD0E-94E703ADDB05
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 710.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
95B82989-6DE2-48B9-B276-A3BE5B79D9A3
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
2F004C04-4144-4757-819D-8F5AD6AB1D77
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
C9E9AA61-1507-4D49-A0D3-56F0FBABFA5F
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
11105D05-C9B8-4543-9935-8BF30DC3567F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 96E8B22E-A55B-4E49-B1AE-93DBB8E7B139
B85946E0-B151-46B3-AB5C-7EE106C2949A
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 704.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 82DA1330-DBB9-43D6-BAF9-FA55DAF5A601
B85946E0-B151-46B3-AB5C-7EE106C2949A
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 704.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 102F9F40-F69E-4B04-9C1E-C7EA25EBDAC3
320F0EAF-4A48-4DE2-983F-092BA8FC43DB
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 102F9F40-F69E-4B04-9C1E-C7EA25EBDAC3
D5EB0B3E-AAE9-4DBA-83AB-CFF08A57A6B1
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 555.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
931B99AA-118A-48DC-998F-2415CCF66980
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
D280C73A-C08D-487F-A744-3705A09B6F02
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
32E62B4F-C42B-4BF7-ACE0-E9527C08212A
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
7302AC94-6AAA-4074-B10C-8CCF69ED0822
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
6A4821E2-4EBE-45F8-90EC-6D046B9BE460
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C0DC1D29-B95B-455C-8F0F-42CF6E13E511
29885E5C-5D06-4F43-9B03-6AE34B8DFC4F
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C0DC1D29-B95B-455C-8F0F-42CF6E13E511
DF6E91C7-C2F9-4DD1-8272-51B4651C7493
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 717.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
5F1B7032-3A52-4989-B879-06F9EEB16408
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
D264C0DB-971B-4C14-9B9E-4B0CA73C2380
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 33 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
82DA1330-DBB9-43D6-BAF9-FA55DAF5A601
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 726.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
65ED1B56-34CC-48F1-81AF-71B20A491C88
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found ACEC7EE8-E7E7-4F4D-8481-ED07320975EE
CA26147F-22AF-4CD3-B3B0-1B5207F36E4A
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 866.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C72C2A0A-A691-4CC3-85A7-2EBB25E257A9
CA26147F-22AF-4CD3-B3B0-1B5207F36E4A
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 866.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
17B9D283-6F78-4A8D-A0CC-990DE348DF3E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
E7CBEDAB-69C3-45A7-A3D5-C0F728DB19F1
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 09BEC59D-D492-43E8-85E0-394F7BEF0944
C3F345F6-F2BB-4DCA-8EE6-4BACD56C9553
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 09BEC59D-D492-43E8-85E0-394F7BEF0944
C51E46BF-F581-40BB-8AEC-A03B2C4D70BD
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 5A8D2266-D756-4EE3-9B78-B45383C14CCB
4438C802-559A-4870-81C1-86E265FA5D78
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 879.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 5A8D2266-D756-4EE3-9B78-B45383C14CCB
6F37BAC4-4727-4C67-9905-50B75D23F54B
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 872.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
066830D0-02FE-4B7E-B3D0-A0D3A07842BF
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
7B3915A2-4E86-4237-909E-8343BB141695
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found CE568E02-A0A7-472A-8E17-8219D9C19567
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 0C608DA6-3310-40FE-BE53-8DAA2337F78A
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
71FDDDA4-89E1-445C-99A7-F0FBA6F6B2EE
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
859C0BFC-B315-4D57-9424-90E381D489C0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 386.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6443C939-BA0F-4583-AD17-6DF35322A218
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found A8B3F9E3-164F-4779-A235-529A1E135F45
CB7B1D3B-76F7-4477-9968-EF5E1395A644
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1676.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 68374965-673C-4F2A-B6E8-1E2A35BB5D67
CB7B1D3B-76F7-4477-9968-EF5E1395A644
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1676.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
0A840E7D-FE17-48F0-853B-F0354F51F022
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
8C8E4204-FD56-4C17-A310-8FC4B169C161
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 6772C9AD-A31C-4F13-BDED-9E3B86D17F45
4964FF3A-30AD-4B6E-AD24-9D63D1CD9687
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 6772C9AD-A31C-4F13-BDED-9E3B86D17F45
7FAA0D8B-BCB2-435B-B446-55B339A528BF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 996F345B-F848-4BD6-B9B8-C05B0BA48C0B
B01771F2-C56C-4FAA-B179-0A0293877130
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 996F345B-F848-4BD6-B9B8-C05B0BA48C0B
BC4596AA-E2EC-4951-BE24-17C999455503
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. EB8F8740-1C62-48B6-9391-56EF77C970A7
F499BF06-D470-4C59-A269-2860205CEB62
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. EB8F8740-1C62-48B6-9391-56EF77C970A7
781921F8-16DC-4148-8A36-F1768EB28D13
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. C384AEFB-93B1-4BAF-99FF-9FE8969585A1
623CD3B8-2DDE-48A8-9179-C09E4F2A953F
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. C384AEFB-93B1-4BAF-99FF-9FE8969585A1
8E9C9035-804B-4E3B-9AA4-0FF258D307CB
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 5B81CDC9-D34A-4F23-953F-0A70F4067335
A478FA25-CD9D-45C2-8819-EA1D38999AFE
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 5B81CDC9-D34A-4F23-953F-0A70F4067335
669E2DB9-13EC-41BB-B90B-E1FC1771F01B
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
045857FD-8CC8-4FA5-9198-44108B9D1C7A
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
B905892F-0103-4F20-A36D-E6A79D3E28C3
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. DE88244C-FCFD-4BF4-A5F8-CD84C1391B2E
BF59EB36-FC17-433F-BC47-8F8FEABB62C6
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. DE88244C-FCFD-4BF4-A5F8-CD84C1391B2E
9898D96D-B47E-49F4-B0B5-A17F8E2D18E7
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 8BBE0AD7-9672-431B-A9C0-ECB390DC4FE9
68629880-6514-4640-8892-C9683773A454
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 8BBE0AD7-9672-431B-A9C0-ECB390DC4FE9
CE40D5F0-55E8-406B-AE97-CA63B3382678
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. B55504D3-7F37-454C-944C-446549C20C06
6BF713A5-D26D-4C64-9EBB-49FCDFDF8510
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. B55504D3-7F37-454C-944C-446549C20C06
A9D2C600-B964-41FD-A64F-191BF7954FEB
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 615CD836-586C-4899-A8EC-E5CBF071A8C7
CC020A15-079C-44EB-A5D5-9B9635CEE6E7
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 615CD836-586C-4899-A8EC-E5CBF071A8C7
84D48DB1-0315-4082-9C76-2FC7741E1750
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
AFFBBDDE-73B9-4003-8175-6176D0CB34F8
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
8CBAB442-DBF1-4C66-B53B-4FFA6E0280BA
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 72D8C652-06C1-4AA6-BDC9-B915F514A9A1
04360B31-EEEE-4164-84AA-258CA6D852E3
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 72D8C652-06C1-4AA6-BDC9-B915F514A9A1
088F9D9A-1CED-4557-969F-0ACA8C2ED545
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
C1948D85-AF84-4861-B057-7FC78370C5F5
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.54 62.6258 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
8B4F079F-D09D-4D0E-BB02-F4A5D9CF735D
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.54 62.6258 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
9A3C04DC-F450-4CE9-A274-EF14EB6B30EC
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
28B9CFF1-406D-439C-8819-E8018BEFA460
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
58A1B05A-7903-43EF-A425-DC709650E9E6
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. AE7BB2C3-935A-48D7-96D5-1121EF0D4258
4504EDC8-3A09-4215-9314-EAB179B09449
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. AE7BB2C3-935A-48D7-96D5-1121EF0D4258
1745BC85-9DE7-4880-85C8-592FA4BB0EDB
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. BD9E7DBE-EC69-49EB-BB12-3F8E102D02D8
F7AF3102-8854-4D06-82F9-F2C5877BF023
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. BD9E7DBE-EC69-49EB-BB12-3F8E102D02D8
32D506C1-860A-4D54-9303-444FABA75B5D
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
C6A484D9-D416-4073-A724-F871B155C244
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
6AC81F90-4F75-4D08-B133-7161F81823E8
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 6625312C-E5BC-4F88-972F-EDDB5B753FC8
A2011AE5-2184-4F99-BE95-9E370D222C1E
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 6625312C-E5BC-4F88-972F-EDDB5B753FC8
1EA58967-EF88-40B2-9089-07D10B2BEF0C
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 39575AB0-8076-476E-925A-81523D3C3F60
509C1B55-BB97-481C-9A79-01414B6D73C4
HSS16X8X1/2 HSS16X8X1/2 BEAM_TO_BEAM HSS 0 43.99 0.00 0.00 0.00 16.00 60.8108 0 0 0 0.00 0.00 0.00 0 0 2033.61 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. C59419E9-8972-4BF5-9C20-03A9CDDC97B5
28466171-702E-4572-BCF6-5B4095ED79AF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. C59419E9-8972-4BF5-9C20-03A9CDDC97B5
92E0E35E-D538-4D44-A6B6-BCF4750ABBF2
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
1BD0A2F8-FBB7-4BDB-935A-7802F28440AF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
F3FAB671-F5DC-4165-8300-1875CBC0E5D8
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Supported connection type not found ECB6AA23-46AF-469E-A288-4C6D229D320C
DA2AC3F8-B4D1-45A2-A3FF-4FE6C2706381
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found ECB6AA23-46AF-469E-A288-4C6D229D320C
BDB3FE16-6945-458A-8933-85A218E5D653
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1682.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8AED7CB3-1990-48B2-849C-E530631ED92C
5412E813-E2FA-4985-81FF-6AB33880D03F
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 555.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8AED7CB3-1990-48B2-849C-E530631ED92C
86F09C66-F195-46C4-987A-9346B1F7608C
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 548.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 2DFE2DB3-B007-4F74-9E03-FAD3F1C597E8
DABCDC7E-620B-4F0C-9EDD-D2301FE53B5F
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 542.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found FE9B06A8-5CE8-4ACA-9F29-DC4D84366934
DABCDC7E-620B-4F0C-9EDD-D2301FE53B5F
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 542.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
34F41067-F048-4FF6-A5F6-771A14541DF9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 7DB6F78D-008F-4DC2-BC7A-72F695E45D03
EE83B50C-847A-45C1-8EC4-E09D213CC957
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 7DB6F78D-008F-4DC2-BC7A-72F695E45D03
65FB6C5C-7E18-499F-B901-66E1DDA96982
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
01C64280-8BAA-4E7A-82AF-5966A61F003C
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
BE2F0B52-28FF-4142-B5BD-CDD8126F7653
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
2D9130AD-4510-44A0-801A-A9B40200F63F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
C97A5DFC-F1A6-40D5-88FE-41A41A19BE96
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
F697EB99-F1D5-42C9-8713-4D01B659EB10
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
FE9B06A8-5CE8-4ACA-9F29-DC4D84366934
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 564.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
3D16E87C-0E63-4FB4-9A26-87FE602ADB2B
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6B3D27A1-140A-4C85-8EB0-D3E348B70ADE
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
9B0E2C9C-B8E5-4C33-9A68-FE2D9B405D16
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 33 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
0C608DA6-3310-40FE-BE53-8DAA2337F78A
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 402.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
3BAFA132-E998-4E83-A9A8-088BBF734FB6
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 110FDB7D-E948-4EE0-A8DB-5F78B2E4CEB9
FC69F2A5-7B66-4A37-B46C-D2EB166EE858
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 110FDB7D-E948-4EE0-A8DB-5F78B2E4CEB9
C645ACDF-CBF4-49CA-BDDB-73A50A41CA39
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
0571F1DD-D7FB-4E06-9599-FF362E17573E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
1C8D917F-19CA-4C8B-82E0-73668B1F3B50
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
2B830D0D-5244-4BCB-A197-D75F75B6EA64
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
AE661D55-0C27-496D-A36F-9D11085D9593
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
A56ACB7F-DE4A-4F17-8843-A463A3291C8E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 1A9F0913-08EF-46F0-AE77-6CD40D1B3689
668E387A-03FF-49A1-8633-494287969E45
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 1A9F0913-08EF-46F0-AE77-6CD40D1B3689
56AA7C1A-BDED-4946-B631-4A4B2F1F7BE5
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1365.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C7213124-48AA-40CB-B8DD-61160DF07882
3364F58C-2A85-4490-9A89-43F0A313E179
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1352.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 73D4FE4C-6B7E-4FC6-9DD3-1EB6DBCDA25A
3364F58C-2A85-4490-9A89-43F0A313E179
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1352.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
04F7C4C1-59B8-4E10-AA17-24920B3B79FE
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
24F99231-0646-459A-8DEB-9F5A68FC13E3
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
874EA2FE-03B2-40C4-9EAD-C394C8A5E382
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
DBD48ED0-AB5B-41C2-BFFB-B2D37F79AFDC
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
B0AE673A-D765-41E0-B4A7-F04A88E8C666
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
73D4FE4C-6B7E-4FC6-9DD3-1EB6DBCDA25A
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1374.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
90CEF738-9F74-4C30-AC0A-C66B721CB70D
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 33758C8D-DEE0-42C7-9857-E163188E4C4F
D87DF215-2550-472A-B2D9-679A849D59F1
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 33758C8D-DEE0-42C7-9857-E163188E4C4F
E8C34D8B-B6BB-4A26-918D-B164D64C11A8
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found E58A3383-350A-4BAA-8926-F472E1C00DDD
E88B5E59-E8B3-4A7C-B9AA-A9735B1D559E
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1365.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found E58A3383-350A-4BAA-8926-F472E1C00DDD
E4031D49-3511-42EA-A012-EFC26269BFE2
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1358.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
6F8F9D4A-CE65-4795-8D60-0CF84203B0CC
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 4BCF7AAF-F7CF-47A4-846C-5E2B9AC9AE1F
A45BC3F4-DCBE-4D0F-88A3-8A9670C5E792
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 4BCF7AAF-F7CF-47A4-846C-5E2B9AC9AE1F
474A1855-92D5-4B39-BE82-668B65BE022D
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1527.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
1C3665B1-9EB0-4E76-977C-038EE62A6D7E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
A195001E-5C5E-4E8D-ADE6-6C345637860D
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
B67002EA-0261-4230-ADD3-63C4590893D8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
0457DCC2-4F3D-4961-926B-E88CC6758B95
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 981E3662-7F39-4A6E-844B-57666BCC7635
3502BAFE-BA8B-464D-B6D0-AF989338A829
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1527.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 981E3662-7F39-4A6E-844B-57666BCC7635
D0504C92-D235-4631-BF87-03B9AE455123
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1520.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
B94B496E-32E7-44D7-9940-1B2A5823C919
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
01870393-240A-4DCE-9A6D-29C866AA14B7
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
BF09E36F-D0F0-470A-9955-FFF6BD961210
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1536.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
2D5287EF-1A68-44EB-9C07-3D2B74835D08
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 9ED7B62F-8CF2-4A54-821D-1C08FC0622BB
72C22C63-26E1-416E-9CB9-3091702BBB08
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1514.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found BF09E36F-D0F0-470A-9955-FFF6BD961210
72C22C63-26E1-416E-9CB9-3091702BBB08
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1514.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
3444EC51-F48B-4E72-AD90-32797CFCA793
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
16832A5A-5232-4077-94FA-1AFF62650811
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
3E6E7C1A-F341-43B0-A948-DCDA985BA9B9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
5821C6D0-4886-4FD4-A652-DE1DE25B2E55
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
527086CD-4698-4E1C-B8E6-A4DB576B4ED9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
910EFF2B-04B1-4E77-8A60-B659AF810FB8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
B5561713-1D05-406C-BC9C-2547074C83A8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
90B14FFD-85F1-4AC9-AE6C-3E8A546AF3A0
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
C72C2A0A-A691-4CC3-85A7-2EBB25E257A9
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 888.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
35E0C90C-B657-4477-A0F9-49E698E6DF8C
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found D685F3E4-DBB2-434E-AA60-4A44443B904E
A31F9A03-3BF9-45BD-9D4D-F468B38694D3
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found D685F3E4-DBB2-434E-AA60-4A44443B904E
317C330F-56B1-413D-B5C3-767C5EE23AF1
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 879.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 36938698-4BA9-41BE-917B-A36EB9A0FC7B
A61582FF-4E92-42CC-A7E1-0303A16F334C
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 36938698-4BA9-41BE-917B-A36EB9A0FC7B
FC6D22D0-DA9F-48AD-9B93-B5DE71C616A6
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found CAC614D6-3930-484F-9374-2165D64F88CF
C10C402F-F9B9-414F-BF73-9C4E42A5B8E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1041.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found CAC614D6-3930-484F-9374-2165D64F88CF
60298E80-7C71-44BB-AA04-8BCB0B4D7B17
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1034.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
F9D1D7F0-91A1-4BD2-8B22-567189A43574
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
B8C2A21D-70E3-497D-AAA5-49E1CACEDA37
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1050.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
39E40769-ADCF-4156-A4B9-F3374555D34D
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 57578118-5DED-465C-8EB1-C8D1958EA3E8
4220FC9B-2BA6-4C93-BE06-3D34A5946ECE
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1028.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B8C2A21D-70E3-497D-AAA5-49E1CACEDA37
4220FC9B-2BA6-4C93-BE06-3D34A5946ECE
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1028.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
D02A7757-F456-43A0-B59C-B93DCC19A86B
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
61D4E711-4FD5-4186-A4E3-CFD5C8A639C6
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
74310FA7-D4E9-4517-965D-DB61F51CBD12
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 51BA6D0D-66C8-4B79-9BBB-B9BF56E39A4C
1AEFBAB5-F3AA-4B0B-8600-A3F6B3EF173F
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 51BA6D0D-66C8-4B79-9BBB-B9BF56E39A4C
4E21892F-B6A4-4DCC-9F2A-9E5B9C687224
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1203.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found ACA670B3-1EC5-4084-9B6A-E01562621B83
B9213A9D-DB05-408D-BE45-4DA9572D3712
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found ACA670B3-1EC5-4084-9B6A-E01562621B83
276B19D4-38A7-4793-AAA1-2D63619FDF9B
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1041.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
AEB73A92-1F8B-41BB-8C02-EA917305324B
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
7F0E6AD2-5981-48AB-AEFC-FD4C32B58530
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1212.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
7FDD9D51-1633-4172-91DA-BEF3BC95E365
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
E96BB49F-6910-4A35-8DCA-EAA699AD4977
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
C4FAC400-9543-4B25-8057-1A6BD4896836
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
FFC21D70-D788-4D4E-8A2A-C03B634BB7D9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
144D2F6D-5C1E-4F9A-9710-4D74C63134EA
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
2A18F2B2-1E72-4FF2-95BC-6ABDD3074436
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1190.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 7F0E6AD2-5981-48AB-AEFC-FD4C32B58530
2A18F2B2-1E72-4FF2-95BC-6ABDD3074436
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1190.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
11EE248B-4BB8-45B9-A582-84EA198C8FD8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C0139783-4A96-4DFD-BC58-47B07868F60A
873E4496-E6AB-4C12-8905-D05CD4E58F7F
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C0139783-4A96-4DFD-BC58-47B07868F60A
5864D340-9DDE-400A-8297-FB64DB071ED1
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 4778A2A0-A24B-4576-A05F-6455A86A3E86
083F3028-0C75-4E10-BC6C-B6C1C5A8937A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1203.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 4778A2A0-A24B-4576-A05F-6455A86A3E86
F19B8712-1AFA-4F4D-B854-9E9E20B18CE0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1196.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. DD10C239-456B-42DE-8ECB-76ADE840A197
3469D7EF-A378-4DD2-9B4E-81ED9840DB64
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
9216A95C-39D8-4394-A7B7-D2065F6D9E5F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. E0B08B4B-BC81-4005-AAC6-417BF00C352B
688A86B8-2381-46D6-A25D-D5B51C8C2797
W16X26 W21X50 BEAM_TO_BEAM NONE 0 -0.96 83.00 -2.64 0.00 12.38 35.6335 0 0 0 0.00 0.00 0.00 0 0 12.985 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
E46D4443-4EE3-40CE-A6A8-A53E76993D59
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.64 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 2.61262 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. 0CD686BD-D8D9-4987-A7F0-569583C5C2C8
ED1C1A21-79A0-4CC0-8B0B-FCE7C2B8DE91
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.86 83.01 -6.06 0.00 15.39 13 0 0 0 0.00 0.00 0.00 0 0 6.56707 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 0CD686BD-D8D9-4987-A7F0-569583C5C2C8
4903CA7E-E6AD-4343-AC38-7B6167850BB1
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.03 0.00 44.94 33 0 0 0 0.00 0.00 0.00 0 0 15.6509 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 98BA463C-687B-46FB-8CE4-D5699B97A882
1E6A7B70-E773-4D07-84EF-18E10E3114B9
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 1.67 0.00 45.00 37 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
E04120CC-0459-4255-B85D-4C65CA61E872
W8X15 W40X167 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.50 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found DFDB1767-0816-4897-85BF-BD729573A8A0
E04120CC-0459-4255-B85D-4C65CA61E872
W8X15 W40X149 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.13 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
8F138495-EC97-4145-AE55-72D8AA4FB1AE
W8X15 W40X167 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.50 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found DFDB1767-0816-4897-85BF-BD729573A8A0
8F138495-EC97-4145-AE55-72D8AA4FB1AE
W8X15 W40X149 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.13 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. B42E0558-18D9-4C70-8132-288D5DAE0E56
C8457151-2FA7-4126-A970-0F262F0199F8
W18X35 W14X22 BEAM_TO_BEAM NONE 0 0.00 -83.09 4.00 0.00 3.51 189.042 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 37D52133-8A74-4741-922F-B00B51799C54
6EF1C0C9-B8C1-4CF2-AFEA-14C05C76E5B8
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 37D52133-8A74-4741-922F-B00B51799C54
49F12458-B474-43E1-BCF7-D75F441EE50E
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
B6F414E4-B7A7-46EE-A141-9B5F17F4A126
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
FF7A9395-D400-47A7-8098-A26BD6B77104
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
7FEAA7D1-8B13-4323-A9A9-61145FF35CD8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
1A488E75-E700-4CCF-96D5-2CDE648BC4F5
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
3445C3F2-BACD-4EAD-88E7-ED1AF860A921
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
A8B3F9E3-164F-4779-A235-529A1E135F45
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1698.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
A779A281-E3BC-4125-A535-E6289CB3F459
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found DC6DB2A9-3885-4421-B0E3-E96E06A3292C
59A05F6D-79C8-4822-B3D4-9C3771A73A58
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found DC6DB2A9-3885-4421-B0E3-E96E06A3292C
5D2155DF-F903-47F5-8117-90FFA45107C6
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found D731B8AB-F16E-4E58-8CF8-9D461F1801BF
67BFA688-A1F6-415F-BCF0-F7362C79DD89
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 231.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found D731B8AB-F16E-4E58-8CF8-9D461F1801BF
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 224.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found D0D59AF9-4838-4A07-9619-2715740F8C0C
C9FC156E-5435-45E4-B3AA-EEC60787CBDB
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 218.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found D5B94786-A91C-4967-982E-220EF3465CED
C9FC156E-5435-45E4-B3AA-EEC60787CBDB
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 218.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E8847A70-26EE-4F36-9DD4-E5D72960DFF1
C8457151-2FA7-4126-A970-0F262F0199F8
W18X35 W18X35 BEAM_TO_BEAM NONE 0 0.00 -83.09 0.00 0.07 3.51 189.042 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E8847A70-26EE-4F36-9DD4-E5D72960DFF1
B8C27D76-6DC1-4E0A-A4CA-D0D29A8D3CCA
W18X35 W18X35 BEAM_TO_BEAM NONE 0 0.00 -83.02 0.00 0.00 19.88 11 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
1B6BF262-F900-4B02-95CD-DD60792C309F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. DFDB1767-0816-4897-85BF-BD729573A8A0
B5257666-8BDF-4CB1-B5B5-2FE0F1608142
W8X10 W40X149 BEAM_TO_BEAM NONE 0 0.00 -90.00 -30.38 0.00 5.63 15 0 0 0 0.00 0.00 0.00 0 0 2018.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
3E81227F-89E2-48F3-A9E8-76C9CAC23401
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -6.00 0.00 10.65 17 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
A84E7E56-49D9-425D-9A4A-F21BECA72F79
W21X62 W18X40 BEAM_TO_BEAM NONE 0 0.00 -84.50 3.12 0.00 22.93 35 0 0 0 0.00 0.00 0.00 0 0 1852 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. CEDE7528-6B1F-4D50-850A-9A5102A35EBC
181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
W18X40 W21X55 BEAM_TO_BEAM NONE 0 0.00 84.49 -2.88 0.00 33.10 34 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
5880CE72-5088-4AC8-BB70-5ABD1DE92D1A
W12X14 W40X167 BEAM_TO_BEAM NONE 0 0.00 -90.00 -26.75 0.00 6.04 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8E614244-7AF7-4A01-B44A-D5C5B158C354
5EF07686-B1FA-445D-8F9D-097EDA5F62FB
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.88 0.00 45.00 40 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8E614244-7AF7-4A01-B44A-D5C5B158C354
4D788503-5989-4F67-92E6-83A453F14569
W16X26 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.13 0.00 24.05 27 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. F614BD41-ACF5-4D7A-BA1A-6EAE5E242BFC
EB0A5650-5372-4B64-95AC-FC05B4CCD970
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 10.23 30 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. F614BD41-ACF5-4D7A-BA1A-6EAE5E242BFC
AA230C34-B299-4560-A4AD-F18C88234A2E
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -88.61 2.00 0.00 20.03 13 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. AA230C34-B299-4560-A4AD-F18C88234A2E
DA837A15-17E7-474D-8AEB-C78E6E5123D4
W16X31 W18X35 BEAM_TO_BEAM NONE 0 0.00 88.61 -1.88 0.00 3.93 137.136 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. AA230C34-B299-4560-A4AD-F18C88234A2E
05CC3659-5B33-490F-A674-98B9FEE33018
W16X31 W18X35 BEAM_TO_BEAM NONE 0 0.00 88.61 -1.88 0.00 35.84 15.0378 0 0 0 0.00 0.00 0.00 0 0 2284.37 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 9653A074-7541-48AF-AE0C-04A23F47DA27
3469D7EF-A378-4DD2-9B4E-81ED9840DB64
W14X22 W10X12 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 62FDF846-535A-4AA7-8554-D2F2C04F3267
9653A074-7541-48AF-AE0C-04A23F47DA27
W10X12 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.88 0.00 10.00 20 0 0 0 0.00 0.00 0.00 0 0 2278.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. E3990C09-536C-417B-B9E9-D92B585C9D73
077A8702-D39A-4573-BF04-B671CAC7F09C
W14X22 W18X35 BEAM_TO_BEAM NONE 0 -0.90 -83.00 -1.83 0.00 11.65 30 0 0 0 0.00 0.00 0.00 0 0 2192.42 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. 6A53AD67-6333-455B-9F59-0F2226A0B78B
077A8702-D39A-4573-BF04-B671CAC7F09C
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.90 -83.00 0.00 0.00 11.65 30 0 0 0 0.00 0.00 0.00 0 0 2190.2 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found E8A24FF6-D411-44C7-892A-FA1889F00148
99258A7A-0375-4955-8AD1-40235B3F4D91
W21X55 W21X48 BEAM_TO_BEAM NONE 0 0.00 90.00 0.13 0.00 45.00 51 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found E8A24FF6-D411-44C7-892A-FA1889F00148
A2B1A411-789E-4F1A-AFC3-123CD3E9B0F5
W18X40 W21X48 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.75 0.00 34.90 38 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
9C51C74D-F5A7-415F-9C4E-37D8F0B1D5A1
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
0542B7B5-89B7-4B84-9C92-9888D6C9A966
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
12F39FB7-FCEF-4F22-815A-BD027E380E53
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
C0CB8698-7ED5-4EF1-B390-EDFC8E7735D5
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 290C7D84-5C46-41F5-A6FD-8B8501FAD362
77E41864-354F-49AA-9333-A1F07AA779E4
W18X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 0.12 0.00 32.38 25 0 0 0 0.00 0.00 0.00 0 0 1848.87 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. 67B642D8-87C2-45AE-80D0-CCC5901103AE
290C7D84-5C46-41F5-A6FD-8B8501FAD362
W18X35 W21X201 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.25 0.00 10.00 66.3834 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 1F15AD9A-5A71-4CE6-9828-DA0D947A6915
06E2CFCC-7D25-4E64-8D50-3A3A180CB582
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.03 0.00 44.90 33 0 0 0 0.00 0.00 0.00 0 0 15.6509 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. 1F15AD9A-5A71-4CE6-9828-DA0D947A6915
83E58AC3-D197-4030-960B-1CA3BB154A00
W12X14 W18X40 BEAM_TO_BEAM NONE 0 1.03 83.00 -6.07 0.00 12.99 11 0 0 0 0.00 0.00 0.00 0 0 6.5562 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. 705D515C-E499-4482-A35F-A4BB13F49404
40CE5947-F5CD-46DF-AEE0-046EA836D0C0
W12X14 W18X40 BEAM_TO_BEAM NONE 0 1.17 83.00 -6.08 0.00 10.60 25 0 0 0 0.00 0.00 0.00 0 0 6.54677 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 705D515C-E499-4482-A35F-A4BB13F49404
598F64BB-7501-4831-8B36-1C12FB2C40E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 44.92 33 0 0 0 0.00 0.00 0.00 0 0 15.6248 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 90686697-E1FE-4886-8998-19A5F135BE4B
09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.63 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 12.624 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
BE049090-A57C-4C73-A746-05B575DA6701
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.98 0.00 45.00 32 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8B36CDC3-2492-42CC-BDA9-7969886A81E0
8A72BC96-3E03-419F-830C-87524A0B7564
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 8B36CDC3-2492-42CC-BDA9-7969886A81E0
B72C4284-5819-4764-929C-560F75E2C85D
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 231.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
0D9E4A9E-DE97-4127-BCCB-8F4F5C561506
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
D0D59AF9-4838-4A07-9619-2715740F8C0C
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 240.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
C0A7913B-9597-4B2F-AE0D-392C249E35E6
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. A40D0707-CB63-494F-B78F-83BF153E7098
15CBF671-1A7F-48E0-A322-40A3772FB251
W14X22 W12X16 BEAM_TO_BEAM NONE 0 0.00 -90.00 1.75 0.00 20.13 16.464 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. FE52CDED-369B-4256-AA0A-3DACCB1205F5
A40D0707-CB63-494F-B78F-83BF153E7098
W12X16 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.75 0.00 23.98 8.36555 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
A07C5B85-BC0F-4A88-B230-F16391582374
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
90C93110-BFCC-4941-9EE0-1AEE00CCCF40
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
0FC65D40-AF42-4477-8454-4987A20902E9
W21X44 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.75 6.00 28.94 25 0 0 0 0.00 0.00 0.00 0 0 2031.37 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
DDA37837-B098-4927-B57D-C9D43D6E426D
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -6.00 0.00 10.68 17 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 97E1E225-1274-49B4-96F0-9C15B10FE79A
4877E884-471D-4F45-8222-520CF12C4AAD
W12X16 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 -5.75 0.00 10.68 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 97E1E225-1274-49B4-96F0-9C15B10FE79A
61C66E6D-542E-4BF3-9658-90E04ECE8007
W21X44 W18X35 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.88 0.00 36.94 31 0 0 0 0.00 0.00 0.00 0 0 2031.37 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 3179739E-F7B7-4E7E-AC14-C1C6A351F7FA
D48B9EE2-BA8C-440F-86B8-335673D9AD8A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 3179739E-F7B7-4E7E-AC14-C1C6A351F7FA
9D1687C6-9FB1-4150-B96F-912EECF9E030
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1844.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 775F59CC-D207-424C-943C-45AD46BDA2C0
AB612E15-8AC9-46E8-9928-FF22A75103C0
W16X26 W21X44 BEAM_TO_BEAM NONE 0 0.00 83.01 -4.88 0.00 15.33 16 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
D609A66D-9839-42BC-92F6-58A3E24E5425
W21X55 W21X83 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.63 0.00 45.00 51 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
704847F5-1E77-4AC8-81D5-37A5BB35BFE0
W18X35 W21X83 BEAM_TO_BEAM NONE 0 0.00 88.05 -3.63 0.00 36.00 37 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
E8A24FF6-D411-44C7-892A-FA1889F00148
W21X48 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 44 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
00D94FA7-CFDE-4CDD-AC5A-6AE0166249D2
W12X16 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
827C55CB-7061-4844-ACF5-05A59FB1CBCA
W16X26 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 29.00 19 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. B50EB32B-3D8D-4945-8CE9-CA3A09181C22
5E8847C6-3429-41E4-83AB-50CC44966987
W14X43 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections to a girder where there is a column flange above or below are not supported yet. E7EC1C34-E0C9-4388-A987-906874F4FE8A
B50EB32B-3D8D-4945-8CE9-CA3A09181C22
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 19.94 16.6145 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 68E06054-293C-4849-BE0D-A5697055AF9F
69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
W18X35 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.25 0.00 20.00 35 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 68E06054-293C-4849-BE0D-A5697055AF9F
FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
41CD1199-5009-48D1-A5A3-FF28C3976D73
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
W18X40 W18X46 BEAM_TO_BEAM NONE 0 0.00 -79.50 -0.13 0.00 33.10 31 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
C4BF2FC5-B3E0-4AC0-995E-51F2D054DEB5
W16X31 W18X46 BEAM_TO_BEAM NONE 0 0.00 -79.50 -2.13 0.00 30.44 24 0 0 0 0.00 0.00 0.00 0 0 1846.87 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
5D257874-B649-4E3D-B083-C64788065277
W14X48 W18X46 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1849 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
4E134221-1035-49CA-B35E-A781B5D4DEBA
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. FD3D037D-5494-438B-9070-EDDC0EA5C82B
26E1EE41-9A11-4EEE-9339-250EB4E1E041
W14X43 W21X111 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2032.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
W18X35 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 20.00 35 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
C276519D-931D-4557-A516-97AAA2C95482
W18X35 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
AC8034FB-ABF2-4728-8CC7-4E64639E9A9B
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 56148724-7135-4712-B68F-305F3B27138C
F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 56148724-7135-4712-B68F-305F3B27138C
9CEB8268-1533-4B64-8788-FE214DA33696
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 34 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 9CEB8268-1533-4B64-8788-FE214DA33696
24DB69A2-3F16-4127-85BA-1827873B72C4
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 213A3419-B118-497F-B4ED-EF9E22803A70
DA3A0C2D-E764-4BC9-8723-5B11909E3C86
W18X35 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 32.52 18 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. DA3A0C2D-E764-4BC9-8723-5B11909E3C86
8CC17800-B31A-4419-9B5E-B83A51B6C175
W18X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 0.13 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. DA3A0C2D-E764-4BC9-8723-5B11909E3C86
06A762CD-6FFA-4D78-8266-515E368F9689
W14X61 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
F8A51DB3-7C7F-4902-B159-1D423CDA90B9
W21X68 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.50 0.00 20.00 20 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 628C0350-A369-48A2-99B0-7FE05F1B8B72
E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
W21X44 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.50 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 628C0350-A369-48A2-99B0-7FE05F1B8B72
2E59BE03-0547-48CE-8014-6690D872C9C7
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. DADA8014-282F-4963-9986-BCFC63188B6F
DA8352A9-E9A4-434F-9E54-A9F6605549E0
W21X44 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 8.50 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. DA8352A9-E9A4-434F-9E54-A9F6605549E0
712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
W21X55 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.13 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
64AE8F49-4E1E-4611-939D-C22BF7153D67
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
DADA8014-282F-4963-9986-BCFC63188B6F
W12X19 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -8.50 0.00 20.00 11 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 3E7EE27E-60E7-4496-AF67-6DA72A755BA5
06EFA10C-AC85-48E2-BB76-4CDD620AB53F
W14X68 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 37D52133-8A74-4741-922F-B00B51799C54
69BF29A6-1BF7-4491-8DED-14279ABDF205
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 88.05 -2.88 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 786212BB-2A21-4285-8839-203B1E887441
313E3F6D-87A2-4330-8BD4-7291B3E9511D
W14X90 W21X50 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 36.06 0 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 786212BB-2A21-4285-8839-203B1E887441
37D52133-8A74-4741-922F-B00B51799C54
W21X44 W21X50 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.25 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1689.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 786212BB-2A21-4285-8839-203B1E887441
C2FE6BF7-F3CB-4951-A189-0B9928695D8A
W18X40 W21X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.00 0.00 20.00 29 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. D9774C64-813D-425A-921B-5050D603A4BC
BBCA9207-8685-48F3-BD48-5586F1327BAE
W14X48 W21X93 COLUMN_TO_BEAM BELOW 0 -90.00 -7.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. D9774C64-813D-425A-921B-5050D603A4BC
B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
W18X60 W21X93 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.38 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
6E81C378-9254-4005-87E7-E622140A8BD9
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
5E8847C6-3429-41E4-83AB-50CC44966987
W14X43 W21X55 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 1281E5CB-B4F0-449C-9E64-513FC966FD48
68E06054-293C-4849-BE0D-A5697055AF9F
W18X119 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 1.13 0.00 45.00 65 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 68E06054-293C-4849-BE0D-A5697055AF9F
2ECEC8F6-06D2-496F-8E27-AFEF34276840
W14X43 W18X119 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 338638BA-B2D9-4CA4-9AC1-2EBE0423FC15
1281E5CB-B4F0-449C-9E64-513FC966FD48
W18X40 W12X16 BEAM_TO_BEAM NONE 0 0.00 -83.02 5.88 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. FC07D5E4-4C1C-4879-AD88-0F9340F1CE4E
338638BA-B2D9-4CA4-9AC1-2EBE0423FC15
W12X16 W18X40 BEAM_TO_BEAM NONE 0 0.00 83.02 -5.88 0.00 11.73 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 628C0350-A369-48A2-99B0-7FE05F1B8B72
A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
W18X40 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.25 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
45B3614A-E04B-4F6A-9E54-7097C38E26A8
W21X68 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 3.25 0.00 20.00 20 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 45B3614A-E04B-4F6A-9E54-7097C38E26A8
ED50100C-D93B-43EB-972A-70EDBA07BF0E
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. C0F54A76-A2F7-47C9-8320-E638CBB91E0C
9DBA1190-D366-4F39-9406-FCE8BDDB6335
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 19.94 16.6145 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 9DBA1190-D366-4F39-9406-FCE8BDDB6335
9A43B315-F54F-4EE0-819F-F5748C979535
W14X53 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections to a girder where there is a column flange above or below are not supported yet. 9DBA1190-D366-4F39-9406-FCE8BDDB6335
E7EC1C34-E0C9-4388-A987-906874F4FE8A
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. DADA8014-282F-4963-9986-BCFC63188B6F
6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. E8607EB6-0BF5-4218-9C92-8EE0225AA17A
9CE6EB0B-EAF3-4FF6-873D-BD8DB74FD3B6
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
DADA8014-282F-4963-9986-BCFC63188B6F
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 11 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
E8607EB6-0BF5-4218-9C92-8EE0225AA17A
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.88 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. F8A51DB3-7C7F-4902-B159-1D423CDA90B9
AE197D6F-29DB-4952-8FA8-91DB5DCFD553
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
09896AA6-F981-4407-97DA-8004F60E7937
W16X31 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.25 0.00 9.44 57.1044 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
58EADA83-DB44-4FE6-85FC-510747343AEB
W16X31 W21X68 BEAM_TO_BEAM NONE 0 0.00 90.00 -5.25 0.00 2.82 191.34 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 58EADA83-DB44-4FE6-85FC-510747343AEB
08410363-4CB8-4991-8A55-247E3759DB6D
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.46 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 1F600D7F-4C5E-495A-86ED-F28C923A50ED
6D23561F-58EC-4295-BEE5-00A1A2EB6173
W14X53 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 6.98 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
FC07D5E4-4C1C-4879-AD88-0F9340F1CE4E
W18X40 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.13 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 775F59CC-D207-424C-943C-45AD46BDA2C0
1F600D7F-4C5E-495A-86ED-F28C923A50ED
W14X22 W21X44 BEAM_TO_BEAM NONE 0 0.00 83.03 -6.88 0.00 14.17 15 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. 775F59CC-D207-424C-943C-45AD46BDA2C0
3F47254E-E617-4C19-8ADF-CE741A29D5DA
W18X119 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.63 0.00 45.00 63 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. E38F5BF5-B3F9-476A-8BF8-011B1208C40A
5AC22012-EAB4-48C9-BAC5-A63A7755EF44
W21X68 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 5.25 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
D2EF0942-F263-4253-BC4B-B59575638260
W14X90 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections to a girder where there is a column flange above or below are not supported yet. 6815E598-889F-410D-A199-6334C0E62A0F
9D406AB8-1B78-4133-BDDA-799B127C0192
W21X44 W18X40 BEAM_TO_BEAM NONE 0 0.00 82.89 2.75 0.00 26.98 47 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 9D406AB8-1B78-4133-BDDA-799B127C0192
709627D5-9623-4FCF-A0B4-AF1FA3793033
W14X43 W21X44 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 62FDF846-535A-4AA7-8554-D2F2C04F3267
C0F54A76-A2F7-47C9-8320-E638CBB91E0C
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 10.00 30 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 62FDF846-535A-4AA7-8554-D2F2C04F3267
380C0450-E673-4C3A-B6DB-9B8B15560968
HSS16X8X1/2 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.25 0.00 17.50 55.6145 0 0 0 0.00 0.00 0.00 0 0 2284.5 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. 380C0450-E673-4C3A-B6DB-9B8B15560968
061CD475-F454-4C42-AC1E-79DCE10446B7
W14X61 HSS16X8X1/2 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
061CD475-F454-4C42-AC1E-79DCE10446B7
W14X61 W21X68 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
83C2ABD3-24A6-4CEB-B831-12BFF1CB9BB8
W12X16 W21X83 BEAM_TO_BEAM NONE 0 0.00 83.01 -9.38 0.00 9.24 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
W21X83 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.13 0.00 20.00 60 0 0 0 0.00 0.00 0.00 0 0 2032.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. FD3D037D-5494-438B-9070-EDDC0EA5C82B
FEF4C8EC-BDB4-4327-BDFC-291A69AB5C22
W14X61 W21X111 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2032.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
1281E5CB-B4F0-449C-9E64-513FC966FD48
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.63 0.00 20.00 31 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. E8607EB6-0BF5-4218-9C92-8EE0225AA17A
D7D680D6-D0E7-4A17-AB9D-EEE8EB5A95A7
W14X61 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 66445B1E-7A02-42C3-A9DF-234872A5B7DF
45586449-08E6-46AC-9C1F-F1730B8F8C85
W14X53 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
66445B1E-7A02-42C3-A9DF-234872A5B7DF
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
9653A074-7541-48AF-AE0C-04A23F47DA27
W10X12 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.00 20 0 0 0 0.00 0.00 0.00 0 0 2278.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. DD10C239-456B-42DE-8ECB-76ADE840A197
E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
W14X61 W16X26 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. DD10C239-456B-42DE-8ECB-76ADE840A197
C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 19.93 16.6231 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
98550496-1EAE-45E3-877C-94C5CF156DE9
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 98550496-1EAE-45E3-877C-94C5CF156DE9
0693463D-E958-47A2-8A6E-6A157F3D5270
W16X26 W14X22 BEAM_TO_BEAM NONE 0 0.00 -67.00 2.00 0.00 21.65 14 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
5733EEB6-E12F-48BF-8369-B6EFB5E40790
W14X43 W21X62 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
8D62A7F1-4DC9-4CFF-8F89-72AA203C5B98
W14X145 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
W21X44 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 39 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
F16F62A7-7E7D-4653-B4DF-E4926C59E7C1
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 31.21 27 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 9D79DD74-29D9-4233-B923-BC24FA2C5CD3
3058B5D6-FE1D-4DC4-8753-07ED34D79B67
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 248161F1-985E-4AC8-BB3C-80AFE7593D46
9D79DD74-29D9-4233-B923-BC24FA2C5CD3
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 3058B5D6-FE1D-4DC4-8753-07ED34D79B67
55C3B4D4-4080-4C0B-8975-98E30CF1B29E
W21X62 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.13 0.00 45.00 56 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
D3FCA134-870E-489A-85DE-89BC970A0259
W14X61 W21X62 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
3449F51F-9875-41AF-B0EB-CC4113E034DE
W14X61 W21X62 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 56148724-7135-4712-B68F-305F3B27138C
7BF637B5-4B36-482F-AC76-9F1D4103CF01
W14X90 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 56148724-7135-4712-B68F-305F3B27138C
E8A24FF6-D411-44C7-892A-FA1889F00148
W21X48 W21X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.13 0.00 20.00 44 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Filler beam workpoint is not between support end points. 56148724-7135-4712-B68F-305F3B27138C
9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
W21X44 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 39 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Filler beam workpoint is not between support end points. 9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
E565E1A1-4654-4BE3-8633-7DF48C63EF26
W16X36 W21X44 BEAM_TO_BEAM NONE 0 0.00 -88.40 -4.75 0.00 33.80 38 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 33E6BC41-0C99-44B6-B465-0AA2D6135BA6
3058B5D6-FE1D-4DC4-8753-07ED34D79B67
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
33E6BC41-0C99-44B6-B465-0AA2D6135BA6
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
92D20A49-A600-4E40-9E2C-F6632FE8BD3B
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.88 0.00 45.00 47 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
F2043603-D371-4973-9114-1C5BA5270DA0
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. DA24DB18-6A90-4E73-B417-15AFA2D6459C
839A1792-276B-4D50-9709-4BB23AA90A8C
W14X43 W24X94 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
E51E3C2A-5BB4-4822-9DE9-C2A7C008F9F3
W14X61 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. DD10C239-456B-42DE-8ECB-76ADE840A197
99BFD3F8-9C08-4097-818C-EDF0A9F0806F
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. DD10C239-456B-42DE-8ECB-76ADE840A197
FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
HSS16X8X1/2 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.25 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
46022672-A263-41E3-BE1B-5233A95442D7
W14X43 HSS16X8X1/2 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 0169F8F2-6ADA-48AE-8C4C-4FE86A105E05
46022672-A263-41E3-BE1B-5233A95442D7
W14X43 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
D0BF0B8B-C43A-4741-989E-6BB05970F7FB
W14X61 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. 98550496-1EAE-45E3-877C-94C5CF156DE9
FE52CDED-369B-4256-AA0A-3DACCB1205F5
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections to a girder where there is a column flange above or below are not supported yet. D83E7D92-5F8D-4E00-AE97-1C88E941B14D
98550496-1EAE-45E3-877C-94C5CF156DE9
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. FE52CDED-369B-4256-AA0A-3DACCB1205F5
8D380BA7-470A-46EB-AC04-0B346404ABEE
W14X61 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 21.48 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 71DEE630-6CEF-42ED-A93D-8FFD7E27B01A
BCA24E27-99E9-4C19-91AD-8602025D509F
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 1F023FF4-695C-42CC-8A12-C825D216A4C8
28F7B09A-AAF8-4FA1-9B99-E55D7C669C39
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. C733972F-E1F6-4272-A287-DB3F2FACF0E0
C9EEF9BF-E989-4DFC-9F93-C24FA7734139
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.875 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. E8FFA5E5-A849-4BD3-99D1-CE641157E4F4
2A73A730-ED7A-4253-B03D-ECE82218B54D
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.94161 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. 380C0450-E673-4C3A-B6DB-9B8B15560968
12271B2D-328A-4980-9C13-72EC0ED7C824
HSS16X8X1/2 HSS16X8X1/2 BEAM_TO_BEAM HSS 0 0.00 90.00 0.00 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. 12271B2D-328A-4980-9C13-72EC0ED7C824
B702B89D-A7C0-4D3A-937D-BCB51C5B7934
HSS14X14X3/8 HSS16X8X1/2 COLUMN_TO_BEAM BELOW 0 -90.00 -90.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
B702B89D-A7C0-4D3A-937D-BCB51C5B7934
HSS14X14X3/8 W21X68 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 9BD7CF86-7C35-4F19-B138-5F71ED3BEC54
1E02AB57-37E5-4ED0-8607-9482A69F05FB
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.39 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
8BA0FDD2-A9DC-4EBE-A84E-23BB3DACE0E2
HSS5X5X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. AE11B7E1-DD01-4CF9-8590-E0107AD83279
27F45B62-0967-4B30-BEA7-86FB2A0B63B3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.94161 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. AE11B7E1-DD01-4CF9-8590-E0107AD83279
B5C69C86-7BB2-4A34-93BC-8EF507044ECE
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.96401 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. E0B08B4B-BC81-4005-AAC6-417BF00C352B
1A7E56F8-6FF5-4621-B2E4-C14BAD41C75B
HSS6X4X3/8 W21X50 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.47 0 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 1F023FF4-695C-42CC-8A12-C825D216A4C8
7C2ED840-1EDA-4D65-B6AC-2048B239B59A
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. A378805D-EF66-4E95-A394-22742217D921
EF44D347-1114-425F-9294-B21DF9CD3489
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 95EB7118-8314-4E74-B818-CE6EF4153278
0C9E4ABC-4B3D-4057-9A7D-CB892D4350FE
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 95EB7118-8314-4E74-B818-CE6EF4153278
9FA14F1A-28C6-4780-99FE-A91C7DC4968A
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. A378805D-EF66-4E95-A394-22742217D921
72D0F3B9-B576-431E-9986-7C9B789A3E10
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 5BA9D70E-D611-46DB-BFA4-A222377D4379
83422ED1-126B-43BB-8E34-1F4606FEBFFB
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 20.92 0 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Beam to Column connections in a group with Column to Beam are not supported yet. AD312723-CCB1-4725-ADB7-8CDEA41E5FB1
E4E53C55-C050-4153-B4DE-EF10D1BA4BA9
W18X35 W14X90 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 -90.00 4.25 0.00 17.33 38.2888 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 57781F4A-CDE7-4FF4-BB86-2DC4061C0C86
AD312723-CCB1-4725-ADB7-8CDEA41E5FB1
W14X90 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. C733972F-E1F6-4272-A287-DB3F2FACF0E0
0DE66CD8-056E-45D6-BB65-15291ECDEAD3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.875 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 71DEE630-6CEF-42ED-A93D-8FFD7E27B01A
A0990116-875E-4BFF-A230-6FB982ADB335
W14X68 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections to a girder where there is a column flange above or below are not supported yet. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
354255C4-13C1-46BD-BA52-8560A1359BA6
W14X145 W18X35 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 6815E598-889F-410D-A199-6334C0E62A0F
59D4C6F3-8A47-4609-99C8-2B08E70B31ED
W14X48 W18X40 COLUMN_TO_BEAM BELOW 0 -90.00 -7.11 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 427C6FEC-A3F4-4B94-AF2F-2036950F72C5
8D0E40CF-D698-4738-BE89-65CC343BF67E
W14X43 W16X26 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. 3E81227F-89E2-48F3-A9E8-76C9CAC23401
427C6FEC-A3F4-4B94-AF2F-2036950F72C5
W16X26 W12X14 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections to a girder where there is a column flange above or below are not supported yet. 9D406AB8-1B78-4133-BDDA-799B127C0192
3E81227F-89E2-48F3-A9E8-76C9CAC23401
W12X14 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -8.75 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
9CEB8268-1533-4B64-8788-FE214DA33696
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 34 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
C276519D-931D-4557-A516-97AAA2C95482
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. C276519D-931D-4557-A516-97AAA2C95482
4326ED42-B1A3-42DD-AB36-B7AC28C3D5EE
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. EB0A5650-5372-4B64-95AC-FC05B4CCD970
61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 36.00 9.20381 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
99BFD3F8-9C08-4097-818C-EDF0A9F0806F
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
40C63F99-248E-48A3-8957-E040456F18F3
W14X43 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 21.43 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 5F3409F2-EEB2-4863-BE3D-F41423B0E21C
40C63F99-248E-48A3-8957-E040456F18F3
W14X43 W21X62 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.43 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 68E06054-293C-4849-BE0D-A5697055AF9F
533D23BF-124A-432B-9A4A-108CBDA05A88
W14X43 W18X119 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
29A4429C-7C11-4369-B150-41A91340B480
W14X43 W18X119 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. D9774C64-813D-425A-921B-5050D603A4BC
932040FE-6BD9-4602-8956-8894D0165AB5
W14X43 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 -7.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. DBBDA364-B5E0-4A93-BBF6-7B4B1998AA26
CF3BF6CE-FA02-4047-B0A3-520C2BABD269
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 5BA9D70E-D611-46DB-BFA4-A222377D4379
62A561CB-EFCE-4140-93FE-BE548C568F08
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 20.92 0 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. DBBDA364-B5E0-4A93-BBF6-7B4B1998AA26
2F5F3FE9-763F-433A-A884-EEE474444560
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.39 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 9BD7CF86-7C35-4F19-B138-5F71ED3BEC54
A2F168E3-D51E-4484-B1CF-CE93B7E3B450
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
8E991592-FBAD-489E-A6E6-610B1365B54A
HSS5X5X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
1884E767-2104-413D-A6D5-E2817A1CBCDA
HSS14X14X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 -90.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. E8FFA5E5-A849-4BD3-99D1-CE641157E4F4
70768AA5-CD06-4FB4-B52E-A002F75353F3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.96401 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
A87D25E9-1CB3-48C8-858C-480496B5824A
W14X43 W16X26 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
427C6FEC-A3F4-4B94-AF2F-2036950F72C5
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 5F3409F2-EEB2-4863-BE3D-F41423B0E21C
C8C2BA86-6C64-46B5-9279-6521E18C5D11
W24X94 W21X62 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 16.60 14 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
499094DD-41A4-4EA3-8B57-D1D407C31029
W14X53 W24X94 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
64E291F4-9FFC-479D-883A-2B6F3CFB9E05
W21X68 W24X94 BEAM_TO_BEAM NONE 0 0.00 68.05 -3.13 0.00 21.56 39 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
93E5BAF9-BF31-489D-B072-86DFC3E13267
W14X22 W24X94 BEAM_TO_BEAM NONE 0 0.00 -90.00 -10.50 0.00 7.85 30 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
17F2540D-9E27-45BD-8D2D-676F5D700302
W16X26 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 35.76 12.3362 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
W21X68 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 5.38 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
3E729E78-C4E4-4E47-BDAA-737205B93C38
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
13699A5D-FF3F-4C95-AD7C-E0A39B386076
W14X90 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. A40D0707-CB63-494F-B78F-83BF153E7098
A3B19E90-7446-4394-A3C4-F37771BD1791
W14X43 W12X16 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
A40D0707-CB63-494F-B78F-83BF153E7098
W12X16 W16X26 BEAM_TO_BEAM NONE 0 0.00 67.00 -3.75 0.00 23.98 8.36555 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
3E729E78-C4E4-4E47-BDAA-737205B93C38
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 -23.00 0.00 0.00 20.00 15 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 67.00 -2.00 0.00 36.00 9.20381 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. DA24DB18-6A90-4E73-B417-15AFA2D6459C
6E4F05C5-C84B-4282-9D3A-759EF54C0C0F
W12X19 W24X94 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. EC9F51C2-9A42-4D6E-B3A7-2573CC3BEB9D
E11A9FA9-4046-4F6F-885B-B84E82038A95
W14X90 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
EC9F51C2-9A42-4D6E-B3A7-2573CC3BEB9D
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.00 0.00 34.21 9.68489 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
349A93AA-A84A-4167-820A-E344A2DBC1F5
W16X31 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1043 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 349A93AA-A84A-4167-820A-E344A2DBC1F5
E04C1F22-7523-4C8C-9792-60EE82E00B47
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 12.55 29.00 8.50024 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. E38F5BF5-B3F9-476A-8BF8-011B1208C40A
9E20047B-C29A-49E9-B3C6-8FC2EF85B368
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
2BD545B9-B4D3-4539-A691-17D35E50301D
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
0169F8F2-6ADA-48AE-8C4C-4FE86A105E05
W21X93 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 45.00 52 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
B19FD047-D193-4F17-BD9A-E647EB2E3A7B
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 0D29E819-F503-405B-B95C-4FF0E5821A33
35B36F33-6288-429B-8D92-DA2A0B197C57
W14X43 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
0D29E819-F503-405B-B95C-4FF0E5821A33
W16X31 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 15 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 15D779B3-01BD-4026-B23A-5946BB50BF7E
5F3409F2-EEB2-4863-BE3D-F41423B0E21C
W21X62 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 5.13 0.00 36.94 42 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 15D779B3-01BD-4026-B23A-5946BB50BF7E
B19FD047-D193-4F17-BD9A-E647EB2E3A7B
W18X35 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 82B6DDE8-5EA9-47A7-99A7-E52B87E0CBF3
09896AA6-F981-4407-97DA-8004F60E7937
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1044 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
330773F5-4848-43C6-825B-2A3F6107354B
W14X90 W12X16 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
W21X68 W12X16 BEAM_TO_BEAM NONE 0 0.00 90.00 9.13 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
6E16102F-7F80-494D-93BE-4F0AC76ECCA0
W16X31 W12X16 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 21.17 25.4609 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 89D99BFB-B6EE-4D8B-8116-1A1BA775D16A
6E16102F-7F80-494D-93BE-4F0AC76ECCA0
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 21.17 25.4609 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 6E16102F-7F80-494D-93BE-4F0AC76ECCA0
213704B6-293E-4CA5-ADD6-B558F50C559D
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 6E16102F-7F80-494D-93BE-4F0AC76ECCA0
E04C1F22-7523-4C8C-9792-60EE82E00B47
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.75 0.00 29.00 8.50024 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
W21X93 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 45.00 44 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
DC9CD579-EADC-4D9B-A308-0777106D1EFF
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 31 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
1F7BFCA6-0252-45BF-85FE-95269A4DED78
W21X68 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.38 0.00 45.00 40 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
DC9CD579-EADC-4D9B-A308-0777106D1EFF
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 30 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
8947A135-68C5-46CC-8E05-B28987D6170A
W14X43 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
W21X55 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.00 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
3B267DA9-DCCA-414C-96DB-D25EBE0A708C
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.94 23 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. E0C6A216-D539-4869-9C0F-BE322A51195F
F7041EBC-0A5F-41C2-A893-054BBEC2EA04
W18X46 W21X68 BEAM_TO_BEAM NONE 0 0.00 74.00 -3.13 0.00 22.70 43 0 0 0 0.00 0.00 0.00 0 0 1849 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 5ACCFAD4-3AF1-423D-B75C-24933259776D
E0C6A216-D539-4869-9C0F-BE322A51195F
W21X68 W21X68 BEAM_SPLICE NONE 0 0.00 -180.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Qnect does not yet support HSS filler beams. FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
12271B2D-328A-4980-9C13-72EC0ED7C824
HSS16X8X1/2 HSS16X8X1/2 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 89D99BFB-B6EE-4D8B-8116-1A1BA775D16A
9E20047B-C29A-49E9-B3C6-8FC2EF85B368
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column to beam connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
0807590A-F1FF-4219-9E8D-5634D9FB6D77
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
D59E77B0-2045-419A-B1D3-BED72A4CFA6A
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 8F7D6983-98F1-42CE-A45B-6297267D17FB
80DF8878-242B-4F70-892F-77645F4FC07A
W14X90 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 8F7D6983-98F1-42CE-A45B-6297267D17FB
D59E77B0-2045-419A-B1D3-BED72A4CFA6A
W12X19 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a beam splice connection. 82B6DDE8-5EA9-47A7-99A7-E52B87E0CBF3
349A93AA-A84A-4167-820A-E344A2DBC1F5
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1043 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a beam splice connection. 349A93AA-A84A-4167-820A-E344A2DBC1F5
8F7D6983-98F1-42CE-A45B-6297267D17FB
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 1.88 0.00 35.67 18.6048 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
9990395D-C5F9-4CA1-8C33-EA8CD33240AF
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1041.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
07F207CA-417E-4698-A4D6-2B2BD28C14F9
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
A1CD8BCC-EE2C-4564-B72F-E5F0082185EA
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
87FF52DD-96F0-4F6A-A339-FED94A5FAFC0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
1474C278-5BCC-4B53-A4F4-54B5E499E9AE
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
72F82F9D-AFEB-4508-BD61-4913D9487AD4
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1036.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
E86CEC60-9811-4F21-8378-1AA264B1D951
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
40BCA70D-9613-449D-A200-39CC88828505
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1039 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA2C79DF-4464-4828-8B5A-DF0586C652DD
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA9B453D-CE7A-4935-AA25-C32EB8CCB2C4
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
E86CEC60-9811-4F21-8378-1AA264B1D951
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
6BA6F088-920D-4379-B9D7-AD918F213074
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1044.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
57578118-5DED-465C-8EB1-C8D1958EA3E8
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1050.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
08611823-A0DF-4724-B96E-4FC82D2E642A
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
40BCA70D-9613-449D-A200-39CC88828505
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1039 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
4BDBC0DA-5AC0-42CD-8785-4004F4C3BC13
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
DE29FF8E-BF33-4A4A-9626-509B85110A73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
C5555BC7-464A-4206-B4E3-AEB9A0610615
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
2C703255-B570-490D-AD12-7B5768716A5A
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
68D61397-09E1-4169-88F2-FA7838BB3027
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
DE29FF8E-BF33-4A4A-9626-509B85110A73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
BE29BE2E-0573-476B-8EB5-09A2916D5146
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
5F45BE64-1227-4A36-ACAF-240C3FCCE685
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
8B94BA7F-178F-428B-A061-0CA609EC4DF0
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
C5555BC7-464A-4206-B4E3-AEB9A0610615
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
D513D20E-A0D4-4979-BEF0-9DA03CA5F2D4
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
EB8F8740-1C62-48B6-9391-56EF77C970A7
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
D513D20E-A0D4-4979-BEF0-9DA03CA5F2D4
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
8B94BA7F-178F-428B-A061-0CA609EC4DF0
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
4A514482-1250-4A1D-82BB-AB906D16E559
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
332A4BDE-4B5B-4DFD-BB8E-A7D5C614EC76
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
C3B67647-C79C-47A0-957D-31D9A00FFE08
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
36938698-4BA9-41BE-917B-A36EB9A0FC7B
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
EB8F8740-1C62-48B6-9391-56EF77C970A7
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C3B67647-C79C-47A0-957D-31D9A00FFE08
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
E402D4C8-8B0E-412D-A2DF-E8234A150806
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
7B5D0835-3264-438C-A363-E584CC040CBC
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
8E939106-3544-4847-A451-02B9FE563093
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
5F45BE64-1227-4A36-ACAF-240C3FCCE685
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
4662964D-09EA-474E-82DF-190E3404786F
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
4BDBC0DA-5AC0-42CD-8785-4004F4C3BC13
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
4A514482-1250-4A1D-82BB-AB906D16E559
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
7B5D0835-3264-438C-A363-E584CC040CBC
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
BD1608D5-8C87-4301-B0C2-A6C3BDE7EE2B
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
79E706EA-CF58-4772-9C52-24C59E7AA11F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
FDA425D1-9A5C-4304-BD4B-B83B47B6A6E1
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
4D69B209-DC9D-4C2E-90A3-363A0EAAB9A8
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
B83E4BFD-35BE-4E6D-A243-7DE904AACCD0
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
2FC6C261-A9BB-460C-8276-697979348CBC
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
618B7D73-0831-411D-83B4-6D185E515F74
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
ECC79D6E-8DF8-48F9-960B-DE3BD0B9B10D
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 715 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
DCC42B0B-8198-48F8-9008-1140575A294A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
5568689A-8E7E-4EFB-B746-91800AF5BBE3
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
4D69B209-DC9D-4C2E-90A3-363A0EAAB9A8
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
90193749-4D48-4485-94A4-712852C1075A
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
E409BE8E-7F0A-4F4E-9E9E-D5C46BA399A3
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
79E706EA-CF58-4772-9C52-24C59E7AA11F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
48F21262-19B0-4C58-B229-37695B5C54A8
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
7C017594-77A8-4254-A474-5466C182C66B
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
B5CEAB43-AD5C-462C-A73B-1CD1C0CF3DB7
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
E4FB8F81-2AEC-4CCE-991C-9E0A5814A3E4
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
CDBC348F-F280-483D-AA9A-21F9BF34D9D7
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
90193749-4D48-4485-94A4-712852C1075A
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
DCC42B0B-8198-48F8-9008-1140575A294A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
814463BF-E07A-4868-BA19-1AF3BBC0F82A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
F1F2E840-F729-4D5E-88C4-2F02C285D9A9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
E409BE8E-7F0A-4F4E-9E9E-D5C46BA399A3
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
F20C520C-6FAB-4611-86E4-E8C30BB2B733
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
E4FB8F81-2AEC-4CCE-991C-9E0A5814A3E4
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
F1F2E840-F729-4D5E-88C4-2F02C285D9A9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
814463BF-E07A-4868-BA19-1AF3BBC0F82A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
2FC6C261-A9BB-460C-8276-697979348CBC
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
52F03D7C-F789-4945-A234-8CEE041E5A17
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
ECC79D6E-8DF8-48F9-960B-DE3BD0B9B10D
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 715 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A4BCA449-3F74-4868-92C4-37314EE32E81
C18CECA7-786E-438A-90F1-3E9D531A96FE
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
10182BFB-3F0E-402E-B372-A4CB2E5E1742
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 27 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
F4EE37B9-E741-4D36-B39B-06EF520F33D4
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
52F03D7C-F789-4945-A234-8CEE041E5A17
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
8A0DC28B-E36F-4C92-9D8F-05A2573685DE
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
513CA458-BCA5-4485-887A-7CCBE0A15528
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 720.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
96E8B22E-A55B-4E49-B1AE-93DBB8E7B139
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 726.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
6D387DF4-1A84-49B7-B50B-FD77E469E6CF
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
F54B8854-C8DD-4C13-8AD5-1335CE677D12
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 877 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
0AA99F9D-AF78-4DD6-8A64-B3B5E44A4B77
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 879.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
44E2EFCE-86D0-4CD9-BAB7-0B0E4D5DA0F4
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
9D890586-34C2-47C3-8614-76DCB516DB1A
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 717.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
E4680621-D95B-4976-BCAE-FC08E98DE74E
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 712.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
02354002-467C-493B-8F08-6C88474D3AD4
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
EBB3572C-49F2-4487-9934-020C03DB822F
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
691C75C1-2582-401A-AEEE-F15C09A6C35E
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
689ADEB9-9825-4A62-88EE-1A1315909242
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
1F94773B-2930-461F-A854-48D77DA01A32
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
3ED42457-E046-4E6B-AF46-8004D040E5DA
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
1F94773B-2930-461F-A854-48D77DA01A32
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
4DCE8FB6-B3C1-4586-8573-8E3AE1C19FF5
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
6772C9AD-A31C-4F13-BDED-9E3B86D17F45
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
4DCE8FB6-B3C1-4586-8573-8E3AE1C19FF5
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
09BEC59D-D492-43E8-85E0-394F7BEF0944
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
6772C9AD-A31C-4F13-BDED-9E3B86D17F45
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
42013A6D-FA13-4A89-BADC-7FB88D1CC700
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
2E8C7F2A-45BB-41E9-A2EC-A1D470577F0F
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
689ADEB9-9825-4A62-88EE-1A1315909242
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
0822EADF-84F2-4E9F-9DF6-F4CE3511C282
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
6903FA2E-8371-4DFB-9E55-F39121BF277D
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
8D0EE022-267E-493E-AD7B-F3D62C548A88
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
4F863091-9932-455D-B755-9D8FB784721A
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
6903FA2E-8371-4DFB-9E55-F39121BF277D
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
5034D831-8F41-417E-A845-25F84C493354
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
1C1FC92B-3571-4867-91E1-3AE35F72C25C
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
F54B8854-C8DD-4C13-8AD5-1335CE677D12
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 877 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DB888ED2-2EFB-4594-B51A-BE66A8A25278
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
206F21FD-019F-4E90-B100-F1A4020AF3B3
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
1C1FC92B-3571-4867-91E1-3AE35F72C25C
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
9ECF74B0-3B1B-4A46-A31F-074BD6CA5067
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3EDF3563-93EB-42E2-94D2-048DCEFD098A
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 882.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
ACEC7EE8-E7E7-4F4D-8481-ED07320975EE
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 888.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
644134AB-98B2-490E-A698-D3D69D9A15E0
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 874.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
08CF93AC-05E4-4744-B7BB-41B07352052B
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
3ED42457-E046-4E6B-AF46-8004D040E5DA
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
38556A05-88D1-49DC-93DC-58ECCDA27F73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
DB58F1F5-9B73-42A2-9855-8519B825AEAC
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
42013A6D-FA13-4A89-BADC-7FB88D1CC700
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
691C75C1-2582-401A-AEEE-F15C09A6C35E
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
38556A05-88D1-49DC-93DC-58ECCDA27F73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
8D0EE022-267E-493E-AD7B-F3D62C548A88
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
6AE98562-7689-4F55-927F-1769383AD9AD
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
5C055762-0D11-4C2D-B0B4-3CF176B40298
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1527.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 313E3F6D-87A2-4330-8BD4-7291B3E9511D
F476C5A2-1C06-4C32-9622-AA025E32CB44
W18X35 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
02E3C9C6-6632-4F27-B884-583D1882EF33
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
A7C16C77-3A1D-47FC-B2F1-148BA4C6AAF3
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1525 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
600E9556-6A64-4F03-B737-E766786707F8
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
DD9BDCFA-1240-4FFB-980D-63D1972D8F95
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
5AEC3194-1010-410D-AB2B-5F5370F3888B
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
60A11EE5-9F01-40A5-A6E6-6F6C8BC49103
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
99CF7CD4-000F-42F4-92B1-FC7C1F9DD098
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2C2A0152-D6D9-4A67-A13A-A5BA5BD894F3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2C3EADC4-CF75-4C6D-894E-41DE9BE3D333
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
1CD20200-26AF-4DD6-9C56-B4ED2100A5B2
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
909A473B-9768-4743-9EB3-DD31AEC2DBF6
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
0B8ED8BF-7302-490B-828A-4FD33A9AA395
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1689.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
3B5CBB2A-756A-4DC4-BFD0-01A234A06FBB
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
D493CF11-869D-4C64-8349-3A093CDF3527
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1687 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C284BE98-8C8B-4F63-A459-B4C32103553D
BBCA9207-8685-48F3-BD48-5586F1327BAE
W14X48 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
B61368C3-F1F0-4877-8A2F-9C1560903460
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
D4CF178C-8391-4B21-849E-53C3C2811D0F
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
A7A435DA-E1FA-430C-A7E0-DC46A2EDD5A6
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
263343D3-EECD-472D-8B1E-BA0725ABB96A
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
E95CC985-766A-40B5-843A-91C246B9ECEA
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1692.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
68374965-673C-4F2A-B6E8-1E2A35BB5D67
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1698.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
7478B226-28CE-49A7-9ABB-1AD84BE3752C
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1684.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
9C094811-32D4-4AC9-8610-0B0ECF2DA51C
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
2ED7D7BE-C726-439C-B383-6161815B50E9
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
B866C8BC-C813-43DF-8D28-DE1206793453
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
A79EAA08-06A7-49D1-BEB0-F4A692CFCE76
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
3A974128-BAE4-4620-A864-5A5DA17CBDA7
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
A79EAA08-06A7-49D1-BEB0-F4A692CFCE76
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
E37DDECD-720B-417F-995A-9C11964818DF
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
4C830EA6-7678-490A-8B36-438FC2E09D1C
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
B866C8BC-C813-43DF-8D28-DE1206793453
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
EFD9D322-8321-42E0-B05C-213EA2EA5BBB
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
E0FA1338-D96B-44F1-A658-7D769EDC882F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
F1DEBF2C-3B33-4DDC-9D7F-86A562F621A6
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
E0FA1338-D96B-44F1-A658-7D769EDC882F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
DAD17DA8-E0C4-4067-AF7A-93553C415567
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
4C830EA6-7678-490A-8B36-438FC2E09D1C
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
B26A91E2-7FBF-47CD-AC68-46CE305F0411
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
D276D777-F9CF-4B9C-96C1-78318DE09FED
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
B9EA48A0-46B8-4028-AC7F-117DADA7DEF0
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
6D3097C1-575C-4A8F-80A0-E9F3AF2AA0A0
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
EFD9D322-8321-42E0-B05C-213EA2EA5BBB
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
3BE858F1-3ED8-41E9-9E63-53B092C374FF
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
D276D777-F9CF-4B9C-96C1-78318DE09FED
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6D3097C1-575C-4A8F-80A0-E9F3AF2AA0A0
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
3A974128-BAE4-4620-A864-5A5DA17CBDA7
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6533527D-87BB-4684-B4B4-7F283841B16F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
6533527D-87BB-4684-B4B4-7F283841B16F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
82BC3F73-3226-43A7-BF39-2F8A5A8DF305
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1198.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
D0C9055C-C95D-4CF0-A952-EC0F4C860212
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
5E4049D3-8400-49DF-97B9-D447A71A47FE
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
F24D6827-EF28-42CE-8A89-F5B5AA91949D
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
9B1E10B9-490A-455C-8B2D-9D7975A2E924
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
B78071DB-FBFB-4858-A7C0-84C0D2439FF0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
C384AEFB-93B1-4BAF-99FF-9FE8969585A1
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
CBFE8BCC-04AA-4588-A971-BD5A0EA51521
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
5E4049D3-8400-49DF-97B9-D447A71A47FE
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
87FF52DD-96F0-4F6A-A339-FED94A5FAFC0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
CBFE8BCC-04AA-4588-A971-BD5A0EA51521
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
A1CD8BCC-EE2C-4564-B72F-E5F0082185EA
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
65551263-D3C7-4A9C-9051-02E863BBE33E
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
AD7F6766-68F3-4FEE-A40A-ACB2241635FF
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
0CD67DF9-7524-4913-9707-A993AAB38E14
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
D8696BAE-DDE7-4C45-B160-DF771D795EEC
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
D27ED056-4C4D-43FB-8EEA-DC310B5B5DD6
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
55E8770B-B960-4C16-B268-11221343DAD8
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
AD7F6766-68F3-4FEE-A40A-ACB2241635FF
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
645DE082-39CA-4731-A6D4-66FE413595C7
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
07F207CA-417E-4698-A4D6-2B2BD28C14F9
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
F24D6827-EF28-42CE-8A89-F5B5AA91949D
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
D27ED056-4C4D-43FB-8EEA-DC310B5B5DD6
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
96032FED-706D-495B-AF80-D6469A64D0E5
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C0139783-4A96-4DFD-BC58-47B07868F60A
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C384AEFB-93B1-4BAF-99FF-9FE8969585A1
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
B78071DB-FBFB-4858-A7C0-84C0D2439FF0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
19922770-D3D0-4B84-A77E-CD6E4ADBDEBC
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C18CECA7-786E-438A-90F1-3E9D531A96FE
C284BE98-8C8B-4F63-A459-B4C32103553D
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3920436F-0D69-42D9-92ED-5EB2A1854AF2
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
B11ABEDF-B74E-47B4-A3D2-00EB87ED4F40
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
0ED27B40-69EC-49F1-821F-463086065E57
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
9B6CCE28-C3CE-4306-BE2C-583C7A374A28
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
30D80433-5F2B-43A3-BB33-539C9C1B3012
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1206.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1212.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
0ED27B40-69EC-49F1-821F-463086065E57
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
D15610A2-DBEA-43C2-BCC7-DF88E58A1448
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1201 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
4DE834F5-0DB8-40AD-992C-DA6638990EFC
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
D15610A2-DBEA-43C2-BCC7-DF88E58A1448
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1201 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
0E759104-908A-4B1E-BF17-38C4378267ED
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1203.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 313E3F6D-87A2-4330-8BD4-7291B3E9511D
087B0D32-CAA8-41A0-844E-8DECB3B64D2D
W18X35 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9FF912D-F57B-4621-AD56-820FFDFF41EB
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
265B3CBE-072B-4CE2-9EE1-FC28AAE074F9
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
D8A4934B-F55F-4590-B143-880EEE11A922
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
06961564-5173-4DBA-B492-336B919CD8AC
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
5EC7EC86-9DDE-43A1-91E4-AE09322B7360
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1368.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C7213124-48AA-40CB-B8DD-61160DF07882
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1374.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
1BE10706-69DF-46B6-A76A-BF37A9E82588
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
2C0FFF3E-B39F-4D78-B522-CBFB10B18124
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
26A03CC8-A1C5-42EA-ACDB-41C953479896
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
1CD20200-26AF-4DD6-9C56-B4ED2100A5B2
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
1BE10706-69DF-46B6-A76A-BF37A9E82588
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
13A4B26E-830E-4BE7-B968-5BB5D175599A
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
600E9556-6A64-4F03-B737-E766786707F8
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
E78330FC-19B4-4101-92FE-E35425AC7D3D
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1522.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
59034CCD-412A-45C4-8B12-024E027CD2E8
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1365.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
65AAB779-19C1-4FB9-BF7C-5FA9B07C72B7
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1360.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
2B42C63E-1F18-4A7E-BB3C-9D526B812C83
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
2C0FFF3E-B39F-4D78-B522-CBFB10B18124
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
60A11EE5-9F01-40A5-A6E6-6F6C8BC49103
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
F6C84A6B-A4B5-4C74-8C90-B67F696BC4F1
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
2B42C63E-1F18-4A7E-BB3C-9D526B812C83
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
F75AA877-EFD5-4760-BF3B-CDB63BF36D84
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
13A4B26E-830E-4BE7-B968-5BB5D175599A
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
F75AA877-EFD5-4760-BF3B-CDB63BF36D84
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
565274B4-2FF2-4D87-B632-1BEC81AE60D8
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
2C2A0152-D6D9-4A67-A13A-A5BA5BD894F3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9B41AB5-9928-4556-B238-0DB97FCBEDA7
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
DB2DCC2D-0928-4A7B-9657-F26B2C0F0C17
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
49CA5CFB-F823-4DB3-9E34-9C81B2DF2602
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
DAB357CC-1145-4228-96A8-B56406947794
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1530.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
9ED7B62F-8CF2-4A54-821D-1C08FC0622BB
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1536.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
125CEAD5-2A48-4C7A-9EEC-3067C05E2FAD
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
5950A269-3C8D-47A4-B6A4-B776976D2A70
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
27C98207-E2E3-420C-808F-1E2C41D23838
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
17DC808C-4200-48A8-BD95-E6D63D750CEE
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
684F750A-1713-4A5B-9C13-67491BF20952
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
F8B7F6EA-09C5-4B44-A782-95698E60E2FE
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
049BBF43-0F2F-45D9-AA4C-62D4530A7A96
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
57570467-7F5C-42C0-93AA-58DB1A1E3350
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
F4E64A91-7316-4339-9A7D-A40E2961872D
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
6831B7C4-D1AB-4A2F-A7F3-045968A9502C
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
33758C8D-DEE0-42C7-9857-E163188E4C4F
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
17DC808C-4200-48A8-BD95-E6D63D750CEE
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
307F3923-F3F1-4797-8B0F-9947D954E81D
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
57570467-7F5C-42C0-93AA-58DB1A1E3350
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
2B54F546-F091-4F35-87A6-0C3CD0529A3B
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
4FACBCAB-A75E-4AE3-B242-588EF02286D3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
049BBF43-0F2F-45D9-AA4C-62D4530A7A96
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
5950A269-3C8D-47A4-B6A4-B776976D2A70
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
FD5DED3E-6F8C-421A-98E3-1C285E33FECC
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
CEA25699-3307-4688-9462-42725037FE0C
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
FD5DED3E-6F8C-421A-98E3-1C285E33FECC
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2DC7B671-44FA-4DA2-B22F-ADF1B217F996
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
4FACBCAB-A75E-4AE3-B242-588EF02286D3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
E9680558-D287-4B05-93C0-A88F87DA6E51
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
125CEAD5-2A48-4C7A-9EEC-3067C05E2FAD
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
F4E64A91-7316-4339-9A7D-A40E2961872D
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6831B7C4-D1AB-4A2F-A7F3-045968A9502C
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
612C667E-1F48-4071-9D75-4F984044C791
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
24790D35-0C18-466A-AD1E-08FE9E5C5E73
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1363 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
A0BF4D51-F4D7-4361-A522-B3827E544B24
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 24 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
705D515C-E499-4482-A35F-A4BB13F49404
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
B5D3DC47-51B0-42DC-8E9D-AE215948B0F9
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.87 83.01 0.00 0.00 9.30 25 0 0 0 0.00 0.00 0.00 0 0 6.48013 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
7ED2D326-C623-4555-9189-37E5CB200D8D
W12X14 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 6.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
FDB433B6-6EF3-43B9-964E-D84A8F0AE59A
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 15 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
D6E8D097-7CCD-4AD9-8E4E-BF98E4C3ED73
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.994 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
99B9CC92-97EC-4D10-8B06-EC68F5EEC225
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
FDB433B6-6EF3-43B9-964E-D84A8F0AE59A
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 11 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
0126C1D4-74D6-4685-80D8-6DCD6791E415
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
553EACB0-7D39-4917-A543-85C8B8FEC36A
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
99B9CC92-97EC-4D10-8B06-EC68F5EEC225
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
C83F4780-5F40-4B15-8CD5-5A82452C20D9
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.05 30 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
B5DD25C8-2788-4505-A2A6-DD77854C02D6
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 14 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
0890C31C-0E92-47C3-8678-FCCE88B205BF
W18X143 W14X61 BEAM_TO_COLUMN FLANGE_BOTTOM 0 0.00 90.00 19.50 0.00 32.48 72 0 0 0 0.00 0.00 0.00 0 0 2030.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
DA3A0C2D-E764-4BC9-8723-5B11909E3C86
W18X35 W14X61 BEAM_TO_COLUMN FLANGE_BOTTOM 0 0.00 -90.00 17.75 0.00 32.52 18 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
D6E76792-486E-4F11-A233-E4513053F9FA
W12X14 W14X61 BEAM_TO_COLUMN WEB_BOTTOM 0 0.00 90.00 11.88 0.00 9.95 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
3FB8FB5A-E6E2-4140-824C-055B07B10A46
W14X61 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2010.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 229 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 9DBDF860-DBFF-4712-AC7A-3A30D8948579
CDA74AA3-DF88-4810-8889-35ACF1918E5F
W18X35 W14X176 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
CB690996-6939-487D-B49E-D45538E58682
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
E3DA22D7-6927-4271-B064-7B4BF029577E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
553EACB0-7D39-4917-A543-85C8B8FEC36A
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
EB4B7D4A-C24F-4499-872A-D652A479E978
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 105.651 0 0 0 0.00 0.00 0.00 0 0 16.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
CB690996-6939-487D-B49E-D45538E58682
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
814803E5-FB62-4ADC-97E3-87E82C9C045E
W12X14 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 229 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E314A306-7243-4D8E-B2B6-AAE799C6E321
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E79D86EE-97AC-4B9A-B282-A608B7763E08
W16X26 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
814803E5-FB62-4ADC-97E3-87E82C9C045E
W12X14 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E9B055B5-F871-4E8C-9996-F7E04F034332
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
W24X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 234.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D5B94786-A91C-4967-982E-220EF3465CED
W30X108 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 240.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
A4BCA449-3F74-4868-92C4-37314EE32E81
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
339B6FFC-483E-4D6C-9039-D2E895C8DC9F
W21X44 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.93 38 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
64E291F4-9FFC-479D-883A-2B6F3CFB9E05
W21X68 W14X61 BEAM_TO_COLUMN WEB 0 0.00 68.05 0.00 0.52 21.56 38 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
DB8BBBDA-7B8C-4FA3-AC76-6DF0013F4352
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
1F15AD9A-5A71-4CE6-9828-DA0D947A6915
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
705D515C-E499-4482-A35F-A4BB13F49404
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 24 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
BFF1BB7B-2C4A-4AF2-8E1B-76A4682D9204
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.68 83.02 0.00 0.00 11.73 25 0 0 0 0.00 0.00 0.00 0 0 6.5242 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
DD2ADE8C-7BCB-4062-B7E8-763D1F1AD88E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
20A14B6C-AFC7-478D-A7D0-E12867770854
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
B402A432-EB6B-4DA1-98B3-C02A78CA3B0A
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
3252DA2D-96CB-4031-9D99-543A1C2D59F3
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
670CCB57-4B65-444C-80B2-28AA76336512
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.65 83.01 0.00 0.00 14.19 12 0 0 0 0.00 0.00 0.00 0 0 6.52873 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
0CD686BD-D8D9-4987-A7F0-569583C5C2C8
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 24 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
1F15AD9A-5A71-4CE6-9828-DA0D947A6915
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
4922D3E0-63E3-45DD-BDCD-28F3357D185D
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 44.90 33 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
3425B209-B0D1-430C-862F-53A0F747EF54
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.90 -90.00 0.00 0.00 21.17 22 0 0 0 0.00 0.00 0.00 0 0 12.6105 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
B5DD25C8-2788-4505-A2A6-DD77854C02D6
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
0126C1D4-74D6-4685-80D8-6DCD6791E415
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
94BBF2A4-A4D1-49A6-9406-4254F86A012D
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
E3DA22D7-6927-4271-B064-7B4BF029577E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
D6E8D097-7CCD-4AD9-8E4E-BF98E4C3ED73
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.994 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
AE7BB2C3-935A-48D7-96D5-1121EF0D4258
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
9AFB54B4-E145-40EC-8DB7-E9729A40D2D0
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
E54E4D50-A406-493F-898E-6B059B28A71C
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
945B9712-14B0-4C6D-8D0E-240621A4E6CF
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
313080E6-FCA6-4F7F-85B0-F1FC944996FC
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
EB4B7D4A-C24F-4499-872A-D652A479E978
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 105.651 0 0 0 0.00 0.00 0.00 0 0 16.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
94BBF2A4-A4D1-49A6-9406-4254F86A012D
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
DC6DB2A9-3885-4421-B0E3-E96E06A3292C
W16X26 W14X283 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
AE7BB2C3-935A-48D7-96D5-1121EF0D4258
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
3252DA2D-96CB-4031-9D99-543A1C2D59F3
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
D0336686-216C-4690-AC5E-0E7D950E66F2
W12X14 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
DD2ADE8C-7BCB-4062-B7E8-763D1F1AD88E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
313080E6-FCA6-4F7F-85B0-F1FC944996FC
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
9AFB54B4-E145-40EC-8DB7-E9729A40D2D0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
E54E4D50-A406-493F-898E-6B059B28A71C
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
20A14B6C-AFC7-478D-A7D0-E12867770854
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
E8AA279A-91C1-44E3-A531-6BEF522F95C0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
28F3829B-C801-4A56-9435-B54D0B4364F4
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
A09FDA1D-56F8-4B6C-8D85-C8ED27DCC97A
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
7866FAFF-8546-4D6D-B0E2-054488B5447E
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
945B9712-14B0-4C6D-8D0E-240621A4E6CF
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
59DACF10-6852-43F9-85B6-6E8CF5997774
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
A53F4FED-4FC1-458C-9DC5-13C1782BF3FB
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
E8AA279A-91C1-44E3-A531-6BEF522F95C0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
920C707D-B075-49B9-9701-A738BFF18234
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
A53F4FED-4FC1-458C-9DC5-13C1782BF3FB
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
48C381A4-0673-44D1-8533-3BD18B793EC0
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
215418CF-5155-4DE7-BF8D-FEA7D331BD5B
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 550.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
CD691887-0366-4900-BB82-ED1344C3C500
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 393.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
E1A24D1C-C617-446C-814B-5DAA9723899B
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
6D7A7A62-7283-4A9F-AA7F-272B51C22F76
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 553 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
51722E2E-DE77-4900-A816-96B0B6630476
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
6D7A7A62-7283-4A9F-AA7F-272B51C22F76
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 553 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
B97C2FC4-AEBC-4586-BFD2-2838ABD4CE22
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
E9A564FA-1924-4FF2-911F-C01F6D2D7BFA
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
51722E2E-DE77-4900-A816-96B0B6630476
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
493FF51E-9946-49B3-AE0A-6B3E3359B27C
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
C467921C-493F-45AD-9E62-A315333FD341
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 558.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
2DFE2DB3-B007-4F74-9E03-FAD3F1C597E8
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 564.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
DB60F5ED-7F55-4689-9444-86D24B90E382
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
3BBA3389-445C-43F3-AF4A-1585B2DFB030
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
142FEC85-4328-46DC-9110-E0FC51D7A18C
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
4508A29D-E08E-4FE2-BDFE-001B670608E9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
F5B0BE9B-BA87-4BC0-AD40-3D5DF02994A8
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
C1BF1EE8-BA5D-4DFA-A1E8-AADDF0163B02
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
7320BF9A-8B9F-4B33-827E-49AFC1FFF44E
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
8809F9F8-675B-48A4-B63B-4061C523CCAE
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
483414A3-6E05-4E69-9401-F9A00FE1A469
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
A4B93EE8-1839-4C1C-A119-DD5B38B9010B
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
4508A29D-E08E-4FE2-BDFE-001B670608E9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
8809F9F8-675B-48A4-B63B-4061C523CCAE
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
CD6957AC-0223-4962-94D8-DFB3E815DFB0
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
A1EA0FCD-E4CD-4D62-B31F-82D016C7D8FB
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
F5B0BE9B-BA87-4BC0-AD40-3D5DF02994A8
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
703BBCFC-E599-4FC0-807B-0FF980FC2EAC
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
6D45C4D1-4942-43F4-BBB8-19F1F5C7A6B7
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
7DB6F78D-008F-4DC2-BC7A-72F695E45D03
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
C59419E9-8972-4BF5-9C20-03A9CDDC97B5
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
A4B93EE8-1839-4C1C-A119-DD5B38B9010B
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
1076266C-185D-4A02-8800-814B68103DA1
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
C59419E9-8972-4BF5-9C20-03A9CDDC97B5
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
F3AB266F-C75E-4888-B28D-4216A7ED2309
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
7320BF9A-8B9F-4B33-827E-49AFC1FFF44E
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
C1BF1EE8-BA5D-4DFA-A1E8-AADDF0163B02
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
F3AB266F-C75E-4888-B28D-4216A7ED2309
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
CD6957AC-0223-4962-94D8-DFB3E815DFB0
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
EF2D951C-8656-44CA-9BB3-4967F028741A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
6D45C4D1-4942-43F4-BBB8-19F1F5C7A6B7
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
73E43823-B9B5-46C0-85C0-8DF1C8F77851
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. D2EF0942-F263-4253-BC4B-B59575638260
97E1E225-1274-49B4-96F0-9C15B10FE79A
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 12.29 53.9937 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. D2EF0942-F263-4253-BC4B-B59575638260
9A311228-BADA-4939-BE09-4284DC537648
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
4AE76E9F-B103-46B2-97C1-87B7FB7EE2B8
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
4026F438-CC44-469E-AC07-AFC814A0CC6A
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
16925C51-1F48-41C3-9177-57A81D862BB3
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
B96F4850-C700-4F58-8D68-715FFB63113B
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.38 56.2751 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
1D0C6816-70F2-4F04-821A-B92F7C1533F8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
2BFAFBEA-D909-48E2-B6C0-B42141CA56D8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
34DCD9A0-605E-45AD-A374-12FB713BAE3D
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
AA7E27DF-A8A1-445A-8B8A-CC454324696A
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
9943EA03-024C-4CF4-A4F3-7F3562E0AD59
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
29A1B8BA-6027-4464-B136-C7B5AA2E4B6D
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
2BFAFBEA-D909-48E2-B6C0-B42141CA56D8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. 8947A135-68C5-46CC-8E05-B28987D6170A
AC5F84E0-62FB-4AE2-A46C-C7BA4A157CF6
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. DBCF94F7-3931-4CEE-AAD5-853E22487073
F16F62A7-7E7D-4653-B4DF-E4926C59E7C1
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
5B977253-D4F8-49D0-8B37-9DF50097A4EB
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
6C7A6345-CDE3-4275-986F-8707EC66583B
W16X31 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 56.7286 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
W16X31 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
18F3B61B-8D5A-4B6C-9C3F-FC3CDE294C18
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 330773F5-4848-43C6-825B-2A3F6107354B
4DB142DD-A279-41FA-8D8F-CF728D3ECCA5
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 213704B6-293E-4CA5-ADD6-B558F50C559D
271D2626-0320-4503-970C-4CDC8E455B81
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 21 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
25257CB7-B2D7-454C-B13E-0901FEDC12CB
W18X60 W14X61 BEAM_TO_COLUMN WEB 0 0.00 68.05 0.00 0.52 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1849.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
6D3D51F9-DBF5-4F75-AD74-88267A6C1C0D
W18X40 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. E7058D14-9D97-4EDD-A51C-89B97DE7273B
00ABD163-DF19-4235-84A3-3A45A12E2153
W12X16 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. E7058D14-9D97-4EDD-A51C-89B97DE7273B
704847F5-1E77-4AC8-81D5-37A5BB35BFE0
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -84.95 0.00 0.00 36.00 42 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
CDDD3D90-928C-4BB1-8EA9-5393C4086352
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
FCE74F5C-7E95-4F46-9C0E-0F0DD1E95B00
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
55785F59-9B60-49F3-B58C-30AA03B68B3D
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.66 15 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
BDD81669-5227-4716-9701-F44DD84165A4
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
E9AF61A6-5511-42A1-897F-9E557B228C89
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 555.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
22CDA226-78CF-4C8F-8DB6-D4D678B63B83
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 29 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
34F8A10A-2A9F-47CF-B528-26A7ECB83C95
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 12.38 16 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
CCC0A360-B70F-43D5-BA9A-8E41DBF25414
W18X40 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 36.90 23 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
F52BD167-B6EE-414B-BE1C-48DE68B38C89
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
678C216D-A746-442C-A380-918D283211AB
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
4026F438-CC44-469E-AC07-AFC814A0CC6A
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
F8BFFA22-B903-4889-B2FF-9C6639EDAB40
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
564E280D-FEBE-4696-A186-76C3576D57AE
W18X40 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
CA56BEEF-CF7E-434A-A0F0-B2490071D5AA
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
16925C51-1F48-41C3-9177-57A81D862BB3
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
BDD81669-5227-4716-9701-F44DD84165A4
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
756CC3BE-1916-4639-9DFD-4E355FC13213
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. 35B36F33-6288-429B-8D92-DA2A0B197C57
E5AF0CBE-0F33-41FC-8FF4-51D22C9E505C
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. 35B36F33-6288-429B-8D92-DA2A0B197C57
96C1C0AD-8B52-4BAC-8C4E-CD714FBFCC6F
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 14 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
A9FD66AF-1B8B-40FB-B3B4-3A8974D6E447
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.44 139.595 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
9B554201-4E20-41FB-9C03-B67659B5C4CA
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.142 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
756CC3BE-1916-4639-9DFD-4E355FC13213
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
D600274F-5111-48FD-BE56-C6FCF27566B2
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.38 170.326 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
A9FD66AF-1B8B-40FB-B3B4-3A8974D6E447
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.44 139.595 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
B96F4850-C700-4F58-8D68-715FFB63113B
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.38 15 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
F8BFFA22-B903-4889-B2FF-9C6639EDAB40
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
AEAF474C-C465-4353-8B72-079B44AF3416
W18X40 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.06 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
D600274F-5111-48FD-BE56-C6FCF27566B2
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.38 170.326 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
D59B5E8B-B476-4D2D-92F1-8EA3E96CD6B4
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 8.76 25 0 0 0 0.00 0.00 0.00 0 0 1842.87 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
FCE74F5C-7E95-4F46-9C0E-0F0DD1E95B00
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
9B554201-4E20-41FB-9C03-B67659B5C4CA
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.142 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
48910073-C648-4C79-9F0E-CDEB6DCCD3A4
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
BBBCBDC5-670D-4FB4-9FBF-08475A340BD4
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
1D961F96-411A-4727-87BD-7D8A18A1F63F
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
1FA52551-429C-4FE3-9ADE-6103A6ADD729
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
AC391EC5-1AE1-47CE-93D8-EC753652C5C2
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
B1FDCED3-92AA-43EB-A47C-440F2C29E99A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
44F4ECEB-4019-4CCF-9644-99195C7DBF03
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. 351414C5-D457-4592-97B4-84B572A89BDF
C6BD7B0E-FCD8-4225-B515-5F0C0B67C7E8
W21X55 W14X257 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 231.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
1D0C6816-70F2-4F04-821A-B92F7C1533F8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
22CDA226-78CF-4C8F-8DB6-D4D678B63B83
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 28 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
6F37001C-CC35-4905-9DB9-73EA829D95F5
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
0BED20DE-5349-42DC-8FE3-2865DBD90D9B
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. DBCF94F7-3931-4CEE-AAD5-853E22487073
239B7ACC-6EA7-4D43-AE1B-50EE332512E3
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 30 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
EF123453-B334-4C60-9DE6-59AB3F1B3CBF
W16X31 W14X342 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 226.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
F7E75267-5AAE-4903-9D0D-8A6597D9DEAF
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
9943EA03-024C-4CF4-A4F3-7F3562E0AD59
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
54EFA1F9-4760-40FC-9B6A-73D0BAACE27A
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
76D141C1-ECEE-4788-8726-50C2028CC89C
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. 4E860B32-D2BC-496D-820D-93AC7D54BF55
C5DFCC2A-AB41-4AE6-BA45-244A2DC38D64
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
837EBA43-8547-4950-875A-672030161388
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
349CC7F8-F40C-4448-816B-00D5C6524398
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
9C13A6B6-FE45-4DB6-844F-777976510FE2
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
37B7C198-D6FE-43A0-A5A8-4A56219C4E40
W21X68 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1852.12 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Qnect does not yet support HSS filler beams. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
76D141C1-ECEE-4788-8726-50C2028CC89C
W18X40 W14X68 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Framing condition is not yet supported by Qnect. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
82621609-0930-4A7A-90E7-335A0781A457
HSS6X6X1/4 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 6.00 0.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
973C2E2B-E36F-42DC-B124-77DA0D022762
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 27 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
C2667425-7FE3-43DB-B0B6-1D3A1E4ED965
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
CFDFBFD6-6E56-4709-B762-C20275E05F4D
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
1AE3987A-FBFA-4479-BE1A-F6142F8F33F2
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
821521D9-8B35-497D-A9B2-11DDBF27AA6F
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 396.375 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
CE568E02-A0A7-472A-8E17-8219D9C19567
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 402.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
4897A67D-6F4F-4B35-B20A-B62C996F935F
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 388.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
CFDFBFD6-6E56-4709-B762-C20275E05F4D
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 79332908-E18B-4B89-A777-5FB4F6F3EF4C
61C6EF8F-F70D-4A29-A6B5-CE6413D750E5
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. ED470781-19F2-4212-B5DF-A6C96B2CBECD
FA2B20A3-4E75-4131-91A7-A614CFDFC746
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
F5FC6427-D2C3-420B-AEED-31A7034FC390
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. BE86D4E7-2CA5-4CB6-9431-C640068DA113
9891A6D6-73F2-4A01-84C5-5A080393E4D6
W14X211 W14X132 COLUMN_SPLICE NONE 0 -90.00 -0.20 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. FE5E2D5C-1417-4F24-9C81-A9255AA51F04
BCAB2633-C665-4DE9-B005-3F8AC0C1711F
W14X120 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 58B83107-5F20-447B-BEB8-A86F72651EE8
BCAB2633-C665-4DE9-B005-3F8AC0C1711F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5C931518-5A05-44EF-A718-E925BB7B94B1
A5437CD8-CE09-438A-A04C-FB59A8C75582
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 18F297E5-76DA-4E32-B991-C804795ED9DF
8915B579-96F9-4355-B4DD-930B01D8E275
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D4A1D721-263B-4B57-A711-206DD3636F2B
C3B6AB56-9E79-4303-AA53-4BED52DCD9E7
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 976194EC-3885-4F9C-8AD2-F926CF6886B0
C3B6AB56-9E79-4303-AA53-4BED52DCD9E7
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 94ECA3BE-EB62-4102-ACA2-674291E7218F
1DEA353D-033A-46DA-BEBE-A85844DA8E76
W14X120 W14X99 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
1DEA353D-033A-46DA-BEBE-A85844DA8E76
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8A9EFCA4-743F-4278-AE8F-610C35E3BED7
D5088096-F760-49AD-915F-741618902EA1
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 7D86E4D7-F48D-456E-AED4-F1499B20B2A0
A9108DB3-8258-4090-BDB0-524D8A7E9B2E
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 198AB2FC-84F3-46CF-9FED-891A7AA29A3B
A9108DB3-8258-4090-BDB0-524D8A7E9B2E
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. F3EDEC65-A90D-4898-A5D1-046B4CFDF563
68BE7F80-CC6D-4762-8DE0-8BEFE27DDAC1
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 3A559CBD-55AD-48E6-A670-10E89C408100
67A81924-72A4-43E9-B3A6-775B5F8AD939
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0BE130D6-D18E-4612-A1E3-F919413279E7
F9375DBA-442E-4B6E-A6D3-D93EB86939C4
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4CCC0250-FFF9-4AF5-8ADB-A75B2E1DB6C3
3698A971-46FC-45EC-B1A8-738CD75AD4EA
W14X257 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4FEA724E-F0C3-4ACA-AFD8-137B8083615C
9D887600-96CA-43B3-8049-3885ED21ED88
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 04DAC6B5-7CAF-4DCF-B790-81EB699E3D41
9D887600-96CA-43B3-8049-3885ED21ED88
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A94E9FCD-F10C-4D9A-A3D4-F02118D4E31A
1FD7B2FE-F5B1-4F0E-859E-61529BE79B2D
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. DE3AE352-A80E-4E1B-B863-3E4F52C83D1D
7A54241B-B68E-4262-8210-0BF51F369A96
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 459BBA95-146B-4DE4-A455-A3A8868F8746
B842C0CA-3A81-4DE0-B3D7-4D6797A042E3
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E1AA0701-83E0-4233-A3D9-53AC4118EBEF
B842C0CA-3A81-4DE0-B3D7-4D6797A042E3
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 9DBDF860-DBFF-4712-AC7A-3A30D8948579
30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 199D1626-4144-4159-A452-3F754AC2FDBD
54AD2023-4C50-4297-B4DF-563A9E989945
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 254E104A-3A1C-4C1A-9853-5744B3552047
31F45CAB-2F14-49FB-ACB6-F07F723118E1
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A60F7B4B-4394-4A19-AA71-DC997EA1EA03
31F45CAB-2F14-49FB-ACB6-F07F723118E1
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. FBDD1DE5-2076-499D-89BE-EF02E3288EE7
4D858208-2A09-4220-BD30-DA2C2FEAB613
W14X90 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 22.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
509F58E7-4085-4E46-9D52-3A072858BDD4
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 7CC96676-4A04-4BE6-B285-A3C9C388FA7F
3F046788-938E-4777-9214-19960D7B760D
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
E0D13FA7-A11F-413F-B5FD-B0545E2B2238
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 1868988C-8768-4AB5-91F9-4C00E69AA95B
F5FFA8C1-21B4-4522-9E3C-33D2A82A168D
W14X99 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 9E5D1E92-A781-4F41-92D7-CCA344D03054
F5FFA8C1-21B4-4522-9E3C-33D2A82A168D
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 2308FF66-29E7-4677-95FC-42AB59DCB43A
766D3CAE-807B-4731-9946-E94B317FDEB7
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 25DDB5D1-4BAC-400F-9D61-C93C00725C38
04E9A7D2-F801-4C42-9930-95E386919649
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5748D66D-3604-46A6-9B2D-C17F09765DEB
6B12E975-80E0-47C2-9110-05B3C2D34B65
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B608D27E-FA9A-40A5-8E55-290C103F50A9
6B12E975-80E0-47C2-9110-05B3C2D34B65
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. 256EEFF9-D368-46E3-86F4-5760B6CE745A
D5B94786-A91C-4967-982E-220EF3465CED
W30X108 W14X176 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 44.92 41 0 0 0 0.00 0.00 0.00 0 0 240.625 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 256EEFF9-D368-46E3-86F4-5760B6CE745A
E0D13FA7-A11F-413F-B5FD-B0545E2B2238
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. EBFF3E23-0757-417D-BE1E-C3ACE8309E71
FCF3AA38-817B-4829-B781-E965BEE60434
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
48EE061A-7EB8-4AA0-B548-FBEF06C6141F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 36B0F1CB-615F-47C7-AB19-E1A13B93CF5B
B9FEAE65-02C3-4DEA-96B1-8A1214E30635
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 9DFB3A01-1130-41C7-82E4-33B818916AD2
87E53653-BDD3-4B75-A233-9DB3B3149B1D
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E4FE6769-C272-4974-8777-AA845DD7091E
D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A254393B-C4CA-46A8-BE5A-5DA128358058
D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
33E416D9-5637-4A34-8A4E-F9A73FEFE321
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
917863AE-38CE-4B33-AEDF-2CC85843B14F
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 2D511FE8-D6A2-4A4C-9F32-F054BB297AEF
9CA600FE-0339-4342-8695-B6231F25261A
W14X211 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
B366A726-300A-4677-B914-2FEC6C93CBB6
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5982A642-8B41-4653-A458-5D49468A0CBA
52A60369-0465-47E3-AB4C-9C78FEE3FF19
W14X211 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
B6696E9B-03DD-4B45-BE1C-79AB81558C51
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0DC49D64-D312-4295-980E-8186405BADF1
6546C29A-342F-41CF-A35B-B0B8A8121786
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
33E416D9-5637-4A34-8A4E-F9A73FEFE321
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
917863AE-38CE-4B33-AEDF-2CC85843B14F
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 1AA81CB9-0E1C-48F4-9936-67143001393A
97E0D34E-2FC7-4F4B-82C9-61BAB429A9E5
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E82B6EA4-9DFE-47FF-B9D0-F16534E8AFDF
79332908-E18B-4B89-A777-5FB4F6F3EF4C
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
234B93AF-4538-475D-9E47-9CC39023D2EB
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D138E37E-1C12-4A9C-BDAC-499BE81AAD51
1FD7B2FE-F5B1-4F0E-859E-61529BE79B2D
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C29CC7BE-FEA7-4F7F-BB3A-2FA142502627
A60F7B4B-4394-4A19-AA71-DC997EA1EA03
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. EDFEBF8B-4EF8-4ED0-9ABB-8ADB5B5AAA66
2D511FE8-D6A2-4A4C-9F32-F054BB297AEF
W14X311 W14X370 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 48.2499 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0BE130D6-D18E-4612-A1E3-F919413279E7
5C925D0A-3A93-4004-AB00-E1CE70D77408
W14X311 W14X211 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 264.004 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5C0B86DC-D2F2-4DD2-AD23-303D10C3F2D2
5C925D0A-3A93-4004-AB00-E1CE70D77408
W14X311 W14X342 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 48.2504 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E05842BC-DDE3-467F-B92A-D2C54AD3EA95
D0BF0B8B-C43A-4741-989E-6BB05970F7FB
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. EA19C6D6-2E82-4892-B19C-54412AF51462
499094DD-41A4-4EA3-8B57-D1D407C31029
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B1CEBEA6-756E-4E0F-8182-2CCAF74CF5D7
6BBACA91-E210-4AD8-B97D-3AA96A9E7C5C
W14X90 W14X145 COLUMN_SPLICE NONE 0 90.00 0.13 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 849D18B6-F17A-437D-81B4-ECB9779C307A
B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
94ECA3BE-EB62-4102-ACA2-674291E7218F
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 25BA3283-EA02-4EFC-ACC6-499E0E2B7005
21F19F0B-25B6-4426-831E-9221191F7162
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5B3C998D-633E-447A-8436-E91E75DD52F0
0A0DF5C0-DE73-42DD-82F9-860DF3D4D4DB
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 804F6CE5-8C92-4234-A4A8-EE007080E0D5
014E5A3F-A64E-4D67-837C-F7685A5B6952
W14X257 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4D1C1EC7-81D8-43C9-BD46-45F1D0E4AA02
E56A7BEB-870C-414D-B0E6-DA41BF1E9951
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.56 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 2052876E-1823-4CF9-A5A1-E235327D49D1
3A559CBD-55AD-48E6-A670-10E89C408100
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 718E8E4E-23D8-4490-A309-35C41B5857A0
A47F26D3-3A1D-47DD-A0ED-05FF144987F1
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 2637778C-DE1B-48B7-9307-B6293C398AE8
274315DF-2A98-467B-9E3F-3340BD4F59F4
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
B5A12E3D-7B9B-4962-8D6B-10C2212F9F5B
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 39.25 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8672619A-330F-427F-B90E-D5FA7749380E
0A4413E4-EEA3-4095-B9FE-32B9E56B12F5
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 1EE71A45-4E74-4978-9FDB-1DF8F3919990
A0B18C57-F5A1-4D6F-8553-695CDB252E2A
W14X61 W14X48 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 51414106-205D-4331-85F6-80A08C0EB129
A0B18C57-F5A1-4D6F-8553-695CDB252E2A
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
8CA384CD-63A7-45E9-999F-804A4789C52D
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0F146864-E5A0-42D6-9916-0AA6FCC7B460
3B4917E8-C019-4738-83DF-DF3E853F06F5
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8F270805-1B17-4B64-A29F-CF9790DB0E5C
C9F26F38-EC3D-4EFF-9674-BD58106FA0E1
W14X257 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A3B9DA33-3DBF-4B64-A3F5-1E976DA661A1
F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 014E5A3F-A64E-4D67-837C-F7685A5B6952
2467842A-34B5-4239-88D0-08878BDBDFB3
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 36.69 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B5A502CD-C6CF-4863-865A-5F9F287F09C6
53853856-6604-43D0-A41A-01558C77B81D
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 99293E55-552F-458D-BE0D-8AEF4F12BA9B
04DAC6B5-7CAF-4DCF-B790-81EB699E3D41
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0A0DF5C0-DE73-42DD-82F9-860DF3D4D4DB
18CD6EE1-AE5C-4C60-933F-92FCA78A859C
W14X53 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 11A61282-48D3-436E-848D-14A7DCACA19E
FE5E2D5C-1417-4F24-9C81-A9255AA51F04
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B5BE23C0-4522-4BDB-8E47-0F43244B58D0
4BCA48E0-FE5F-48A2-AB7B-D6AE926C4201
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 66FFFA38-CAF9-4665-B00F-A08260F332DF
E823BBFD-103C-4562-8321-E61691DA5016
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 39.25 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
AA759B66-B163-41C5-8DDF-AE56C1F84BD1
W14X257 W14X233 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 37.13 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 274315DF-2A98-467B-9E3F-3340BD4F59F4
728BCB88-307A-4127-B12C-009280BAC82D
W14X90 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 857B257E-6DED-42D3-A72C-4697CA4480AF
6E7617B0-54CC-45C4-853A-1F013E64C550
W14X61 W14X43 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 1868988C-8768-4AB5-91F9-4C00E69AA95B
6E7617B0-54CC-45C4-853A-1F013E64C550
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 85D8F200-BC22-4D70-A06F-09BDA98BBB38
9A43B315-F54F-4EE0-819F-F5748C979535
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C29CC7BE-FEA7-4F7F-BB3A-2FA142502627
2ECEC8F6-06D2-496F-8E27-AFEF34276840
W14X43 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 6F5B61CE-BF3C-4ED1-A8D2-1CF234A78487
6D23561F-58EC-4295-BEE5-00A1A2EB6173
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A94E9FCD-F10C-4D9A-A3D4-F02118D4E31A
A651599F-786B-4CBE-BF42-8E36DB79C3AD
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A37ED7B7-1F1E-4221-854A-22E084052C34
213704B6-293E-4CA5-ADD6-B558F50C559D
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
2BAE0A0B-E0B3-4569-B1DD-6E9E654A6B62
W14X120 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
W30X108 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 44.92 41 0 0 0 0.00 0.00 0.00 0 0 1212.63 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. DAA426C2-C841-4BA6-A704-EFEF817CC8DB
22FCAB24-283B-4790-85CF-D3E541B41664
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 134936D7-07A4-41B1-A8DE-EF7052CB2656
313E3F6D-87A2-4330-8BD4-7291B3E9511D
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 36.06 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5ECE6F2E-78AD-4838-9911-EFB264999596
E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
W14X120 W14X90 COLUMN_SPLICE NONE 0 -90.00 -0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. BE86D4E7-2CA5-4CB6-9431-C640068DA113
E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. DE3AE352-A80E-4E1B-B863-3E4F52C83D1D
776B310A-DBC0-419D-97AF-AAB6EE882274
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0D102D6C-E337-4D1D-A0C6-DF1CEEEFE55F
0DDE526F-4027-4C3D-9971-C7C84A4DF35C
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5748D66D-3604-46A6-9B2D-C17F09765DEB
4905A174-F477-4655-A0E4-D1EEB324BD23
W14X120 W14X120 COLUMN_SPLICE NONE 0 90.00 1.42 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A825CA09-646F-4F0E-A88D-C195109686C6
CDE31233-C3C7-4CBC-8918-8C0842DF2791
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D4A1D721-263B-4B57-A711-206DD3636F2B
C685F2B8-A6FF-4398-9B6E-7A877FF10113
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 7D86E4D7-F48D-456E-AED4-F1499B20B2A0
38EDDDC4-866F-44CE-BD8E-AAB3CFF6FFE7
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 975BA93D-8B91-4FAC-8FD1-22145813F256
DBC72FA1-D71C-4823-9A42-17862FEC23B2
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0EDEBE74-842C-4C52-804E-B50CC340296B
9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. F9375DBA-442E-4B6E-A6D3-D93EB86939C4
E168056A-8C92-4709-BDE8-4979BA5C6259
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
96B87704-8949-45CC-B092-EB20FB25B31F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 3EF528DA-76E8-4B14-B1E3-696A796126E6
8152E62A-47CB-479D-A4C7-ECCF842B45EA
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 1EE71A45-4E74-4978-9FDB-1DF8F3919990
68AF7010-8250-4FCA-9003-31E8DD0E88C2
W14X43 W14X48 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 18CD6EE1-AE5C-4C60-933F-92FCA78A859C
D7D8F5C3-F5CD-4EBA-9149-3201EBD95C77
W14X53 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 11A61282-48D3-436E-848D-14A7DCACA19E
9CE6EB0B-EAF3-4FF6-873D-BD8DB74FD3B6
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 2637778C-DE1B-48B7-9307-B6293C398AE8
ADFE58A3-0F4A-44FC-B5FF-98E8488A18CD
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. F9F6C52F-4EDB-46B7-A491-6CDF3350ECC9
B76C4CD9-E923-4CA3-B6DF-58C8DF0EABF7
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E4FE6769-C272-4974-8777-AA845DD7091E
E02CA80D-FC59-4556-B8EE-65046563BC1A
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 66FFFA38-CAF9-4665-B00F-A08260F332DF
ABEE8C90-15B1-496B-A85C-EE3B3CDCBCE1
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 749.754 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0BE172C5-6C31-4CAD-98FC-BEAF6FEE878D
BCA24E27-99E9-4C19-91AD-8602025D509F
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.78 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B9FEAE65-02C3-4DEA-96B1-8A1214E30635
7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 746.243 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 1E08BF51-F015-4461-8A0E-C73E08553BCE
41CD1199-5009-48D1-A5A3-FF28C3976D73
W14X109 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4D272FF9-FA56-4468-89E4-F6FA5735A05B
AE197D6F-29DB-4952-8FA8-91DB5DCFD553
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 90.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.17 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4D5B338E-7968-48D1-9BDB-20093C0CF8B0
28C5BA0D-415B-4012-BCAB-FC953FEB85E0
W14X145 W14X193 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1233.13 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C6FC0258-DCB5-4EBD-B503-598DCEEDA2A9
4E860B32-D2BC-496D-820D-93AC7D54BF55
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0DDE526F-4027-4C3D-9971-C7C84A4DF35C
4B975AA9-C7BE-4936-BCCE-89148831E8CB
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 89.41 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 234B93AF-4538-475D-9E47-9CC39023D2EB
0807590A-F1FF-4219-9E8D-5634D9FB6D77
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E168056A-8C92-4709-BDE8-4979BA5C6259
330773F5-4848-43C6-825B-2A3F6107354B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2263.27 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
90D3759D-A468-44EC-8E1E-D8C401E416DB
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
D2EF0942-F263-4253-BC4B-B59575638260
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B76C4CD9-E923-4CA3-B6DF-58C8DF0EABF7
E7058D14-9D97-4EDD-A51C-89B97DE7273B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8152E62A-47CB-479D-A4C7-ECCF842B45EA
13699A5D-FF3F-4C95-AD7C-E0A39B386076
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 96B87704-8949-45CC-B092-EB20FB25B31F
E11A9FA9-4046-4F6F-885B-B84E82038A95
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E02CA80D-FC59-4556-B8EE-65046563BC1A
80DF8878-242B-4F70-892F-77645F4FC07A
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6B7D2987-C9E2-4534-BA41-E614B5EB444E
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 16108B12-3ED5-4562-B5B1-03AAD09FC446
ED50100C-D93B-43EB-972A-70EDBA07BF0E
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. CF07F7C4-B4D1-4144-B718-102215DF7786
64AE8F49-4E1E-4611-939D-C22BF7153D67
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. CDE31233-C3C7-4CBC-8918-8C0842DF2791
EFDE2B89-981B-433F-8CD6-17ED3BF4C148
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 38EDDDC4-866F-44CE-BD8E-AAB3CFF6FFE7
06A762CD-6FFA-4D78-8266-515E368F9689
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 456239D1-6988-418B-9D36-C38E6C17CA05
3449F51F-9875-41AF-B0EB-CC4113E034DE
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 429C8C48-CA88-405B-8AF1-B545D954B2AE
A0990116-875E-4BFF-A230-6FB982ADB335
W14X68 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 519FDEFE-13BD-46F9-8644-7D891121E73C
3FB8FB5A-E6E2-4140-824C-055B07B10A46
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E9CBDE30-BE05-4801-8593-128620AE5C7D
354255C4-13C1-46BD-BA52-8560A1359BA6
W14X145 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D2CDAB23-BFC1-4CA4-8410-378E31F3A209
59D4C6F3-8A47-4609-99C8-2B08E70B31ED
W14X48 W14X48 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A2915901-C53B-4A9A-B9DE-9F1FCF4D4C9E
8D0E40CF-D698-4738-BE89-65CC343BF67E
W14X43 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 035ED350-53E8-4774-BDA6-DA87F9D1E2EB
7A54241B-B68E-4262-8210-0BF51F369A96
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.949 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 318A24E1-4A86-4E34-BD86-6ABA04648AAB
4326ED42-B1A3-42DD-AB36-B7AC28C3D5EE
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 13C6FBA8-D028-4B31-9D3F-5D111A5CD0F0
79FD091A-B1CE-4014-A0A4-6E3A91F6AB14
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 8.40 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
9258B322-7F52-4655-AECB-8BBBCB754CF5
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.16 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1229.52 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 9258B322-7F52-4655-AECB-8BBBCB754CF5
4D272FF9-FA56-4468-89E4-F6FA5735A05B
W14X132 W14X193 COLUMN_SPLICE NONE 0 90.00 90.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.5 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
DBCF94F7-3931-4CEE-AAD5-853E22487073
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4905A174-F477-4655-A0E4-D1EEB324BD23
4E134221-1035-49CA-B35E-A781B5D4DEBA
W14X109 W14X120 COLUMN_SPLICE NONE 0 90.00 1.05 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1723.34 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. DA9F25BC-167E-4DE7-A9FE-0BDC46482C0F
8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.009 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
96FEE1F7-7165-4EFA-8E9F-895881561ACC
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 748.774 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 351414C5-D457-4592-97B4-84B572A89BDF
9891A6D6-73F2-4A01-84C5-5A080393E4D6
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 265.021 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
F5FC6427-D2C3-420B-AEED-31A7034FC390
W14X211 W14X342 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 263.483 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 68AF7010-8250-4FCA-9003-31E8DD0E88C2
6183D7E5-CFCA-4136-ACC8-792EC36CB012
W14X43 W14X43 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 36.68 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A37ED7B7-1F1E-4221-854A-22E084052C34
4A851DC9-81A8-430C-9E92-B0040852819A
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. FA2B20A3-4E75-4131-91A7-A614CFDFC746
4A851DC9-81A8-430C-9E92-B0040852819A
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D5088096-F760-49AD-915F-741618902EA1
687731D8-D93F-4369-A84B-AE8EC61D855A
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A5437CD8-CE09-438A-A04C-FB59A8C75582
A825CA09-646F-4F0E-A88D-C195109686C6
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 456239D1-6988-418B-9D36-C38E6C17CA05
E9E2186B-1328-44FC-A23E-06A54FBF638C
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 3F046788-938E-4777-9214-19960D7B760D
E9E2186B-1328-44FC-A23E-06A54FBF638C
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0BE172C5-6C31-4CAD-98FC-BEAF6FEE878D
7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
W14X193 W14X132 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Part of group with Not connected due to being a column splice connection. 0A4413E4-EEA3-4095-B9FE-32B9E56B12F5
B4047916-F629-490E-A1C9-F1A1216D9BA0
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1235.99 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 16108B12-3ED5-4562-B5B1-03AAD09FC446
B4047916-F629-490E-A1C9-F1A1216D9BA0
W14X193 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C4492C55-333F-4524-A162-75AAC54BCC30
47A1B78B-9A15-4D5D-A8C0-15E1ABEF088B
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 3B4917E8-C019-4738-83DF-DF3E853F06F5
47A1B78B-9A15-4D5D-A8C0-15E1ABEF088B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A3B9DA33-3DBF-4B64-A3F5-1E976DA661A1
3C3C0857-2A00-4ACE-94D3-67DC25F096E2
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8915B579-96F9-4355-B4DD-930B01D8E275
3C3C0857-2A00-4ACE-94D3-67DC25F096E2
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E05842BC-DDE3-467F-B92A-D2C54AD3EA95
D462CB20-218C-41E3-A4FF-E9488A8B1861
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A47F26D3-3A1D-47DD-A0ED-05FF144987F1
D462CB20-218C-41E3-A4FF-E9488A8B1861
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. FCF3AA38-817B-4829-B781-E965BEE60434
4C2D5349-D1BF-44CB-B18B-E237F9E8ED9C
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 608A8D89-92CE-420D-A377-B0B0A969C19D
13C6FBA8-D028-4B31-9D3F-5D111A5CD0F0
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D2064BCF-9BD5-46A1-85D5-AEED10AE8551
A4B7B146-0337-4286-B35F-D8B15F1A4FDB
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 608A8D89-92CE-420D-A377-B0B0A969C19D
6DA25684-81FD-4DB7-9AE4-ABA3CB9A9A40
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. CFD14E8A-055D-48E7-AEF8-7CEAC63E3845
6DA25684-81FD-4DB7-9AE4-ABA3CB9A9A40
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4BCA48E0-FE5F-48A2-AB7B-D6AE926C4201
DAA426C2-C841-4BA6-A704-EFEF817CC8DB
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 0DDEE9E7-03E6-4812-A4C1-F06AC8876D53
9070ACE5-AF7E-4667-9DBD-8AB7C8365DD9
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 766D3CAE-807B-4731-9946-E94B317FDEB7
9070ACE5-AF7E-4667-9DBD-8AB7C8365DD9
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 96D43969-72D6-48D4-A185-6FA61BE85F1F
B4010245-3B7C-4CAA-95ED-A836EF7C3344
W14X90 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
F9F6C52F-4EDB-46B7-A491-6CDF3350ECC9
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 318A24E1-4A86-4E34-BD86-6ABA04648AAB
4EEFEF1C-2E0E-497B-9EC2-97EC40BEC890
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 68BE7F80-CC6D-4762-8DE0-8BEFE27DDAC1
4EEFEF1C-2E0E-497B-9EC2-97EC40BEC890
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. F3004609-63D0-420E-B92C-2AEA3D319B66
113ADEAB-1E0C-4E18-83F3-F64DD28473FF
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 8CA384CD-63A7-45E9-999F-804A4789C52D
113ADEAB-1E0C-4E18-83F3-F64DD28473FF
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 9CA600FE-0339-4342-8695-B6231F25261A
3EF528DA-76E8-4B14-B1E3-696A796126E6
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
31137C4F-3F63-438D-AFDB-7950376A8126
W14X53 W14X53 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B366A726-300A-4677-B914-2FEC6C93CBB6
31137C4F-3F63-438D-AFDB-7950376A8126
W14X53 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. EA539FBB-004F-446D-B763-D2D5DAF4CABE
ABEE8C90-15B1-496B-A85C-EE3B3CDCBCE1
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1235.51 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 509F58E7-4085-4E46-9D52-3A072858BDD4
B4010245-3B7C-4CAA-95ED-A836EF7C3344
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 97E0D34E-2FC7-4F4B-82C9-61BAB429A9E5
5DD876A1-A3FF-4464-8BA9-041F810834A8
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. EA19C6D6-2E82-4892-B19C-54412AF51462
695DEE27-D1D4-4359-BA69-F51FC052A6A5
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
695DEE27-D1D4-4359-BA69-F51FC052A6A5
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. FC9AE33D-E8B2-4209-B8FB-2CDA0A905896
CEA25DD3-355C-4167-9323-9C662177C0D1
W14X68 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 54AD2023-4C50-4297-B4DF-563A9E989945
CEA25DD3-355C-4167-9323-9C662177C0D1
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 697AF9C6-D06C-4821-B156-FA00822F4358
9BF69AC7-B5FC-4B4C-98C5-4CAF68B9C641
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C9F26F38-EC3D-4EFF-9674-BD58106FA0E1
9BF69AC7-B5FC-4B4C-98C5-4CAF68B9C641
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
134936D7-07A4-41B1-A8DE-EF7052CB2656
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 429C8C48-CA88-405B-8AF1-B545D954B2AE
50546E67-F121-4E6E-98C4-D115C89553F7
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A4B7B146-0337-4286-B35F-D8B15F1A4FDB
0D102D6C-E337-4D1D-A0C6-DF1CEEEFE55F
W14X132 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. BFEE8ADB-BB96-4E92-BBE8-B52C6A6B5ED4
E9CBDE30-BE05-4801-8593-128620AE5C7D
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 4C2D5349-D1BF-44CB-B18B-E237F9E8ED9C
F8936F8C-437A-4661-AF27-2EAC8E077DFB
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. FC9AE33D-E8B2-4209-B8FB-2CDA0A905896
7AF1A487-25FD-474C-ACFA-2872A3AE369A
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. F3004609-63D0-420E-B92C-2AEA3D319B66
08410363-4CB8-4991-8A55-247E3759DB6D
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.46 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
35B36F33-6288-429B-8D92-DA2A0B197C57
W14X43 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 67A81924-72A4-43E9-B3A6-775B5F8AD939
C6FC0258-DCB5-4EBD-B503-598DCEEDA2A9
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 61C6EF8F-F70D-4A29-A6B5-CE6413D750E5
CF07F7C4-B4D1-4144-B718-102215DF7786
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 3698A971-46FC-45EC-B1A8-738CD75AD4EA
BFEE8ADB-BB96-4E92-BBE8-B52C6A6B5ED4
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
50546E67-F121-4E6E-98C4-D115C89553F7
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 519FDEFE-13BD-46F9-8644-7D891121E73C
3E7509DC-FDAC-4C5E-921A-3222F6C2680E
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 21F19F0B-25B6-4426-831E-9221191F7162
3E7509DC-FDAC-4C5E-921A-3222F6C2680E
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 87E53653-BDD3-4B75-A233-9DB3B3149B1D
975BA93D-8B91-4FAC-8FD1-22145813F256
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. E1AA0701-83E0-4233-A3D9-53AC4118EBEF
D14C1B40-3446-429D-9383-FD0C2F23B815
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 687731D8-D93F-4369-A84B-AE8EC61D855A
85D8F200-BC22-4D70-A06F-09BDA98BBB38
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 804F6CE5-8C92-4234-A4A8-EE007080E0D5
47A6DB92-BBD5-4DE0-AF61-41DE5780F226
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
0EDEBE74-842C-4C52-804E-B50CC340296B
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 6F5B61CE-BF3C-4ED1-A8D2-1CF234A78487
5DD876A1-A3FF-4464-8BA9-041F810834A8
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B5A502CD-C6CF-4863-865A-5F9F287F09C6
AF8300FF-515D-4DFA-A6AC-B8B2971656AB
W14X61 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. A2915901-C53B-4A9A-B9DE-9F1FCF4D4C9E
1763B868-4EC6-46BA-A989-914FD8B07FEF
W14X61 W14X53 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. FBDD1DE5-2076-499D-89BE-EF02E3288EE7
1763B868-4EC6-46BA-A989-914FD8B07FEF
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. B6696E9B-03DD-4B45-BE1C-79AB81558C51
DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 6546C29A-342F-41CF-A35B-B0B8A8121786
A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 1E08BF51-F015-4461-8A0E-C73E08553BCE
71FC28AB-78D1-4BED-9262-C73D09A3E8F2
W14X120 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. 04E9A7D2-F801-4C42-9930-95E386919649
71FC28AB-78D1-4BED-9262-C73D09A3E8F2
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Baseline 2018-08-31 18:06:55 Not connected due to being a column splice connection. D2CDAB23-BFC1-4CA4-8410-378E31F3A209
AF8300FF-515D-4DFA-A6AC-B8B2971656AB
W14X61 W14X48 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
E3455F56-6C77-441E-9E49-B0B502610F16
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 63CBDC7A-526B-403B-86DB-4C0079A350C7
C0868018-EAD8-495C-93DD-349011F247FB
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 717.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 63CBDC7A-526B-403B-86DB-4C0079A350C7
89910F0B-27B8-4202-AD0E-94E703ADDB05
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 710.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
95B82989-6DE2-48B9-B276-A3BE5B79D9A3
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
2F004C04-4144-4757-819D-8F5AD6AB1D77
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
C9E9AA61-1507-4D49-A0D3-56F0FBABFA5F
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
11105D05-C9B8-4543-9935-8BF30DC3567F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 96E8B22E-A55B-4E49-B1AE-93DBB8E7B139
B85946E0-B151-46B3-AB5C-7EE106C2949A
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 704.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 82DA1330-DBB9-43D6-BAF9-FA55DAF5A601
B85946E0-B151-46B3-AB5C-7EE106C2949A
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 704.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 102F9F40-F69E-4B04-9C1E-C7EA25EBDAC3
320F0EAF-4A48-4DE2-983F-092BA8FC43DB
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 102F9F40-F69E-4B04-9C1E-C7EA25EBDAC3
D5EB0B3E-AAE9-4DBA-83AB-CFF08A57A6B1
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 555.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
931B99AA-118A-48DC-998F-2415CCF66980
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
D280C73A-C08D-487F-A744-3705A09B6F02
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
32E62B4F-C42B-4BF7-ACE0-E9527C08212A
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
7302AC94-6AAA-4074-B10C-8CCF69ED0822
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
6A4821E2-4EBE-45F8-90EC-6D046B9BE460
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C0DC1D29-B95B-455C-8F0F-42CF6E13E511
29885E5C-5D06-4F43-9B03-6AE34B8DFC4F
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C0DC1D29-B95B-455C-8F0F-42CF6E13E511
DF6E91C7-C2F9-4DD1-8272-51B4651C7493
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 717.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
5F1B7032-3A52-4989-B879-06F9EEB16408
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
D264C0DB-971B-4C14-9B9E-4B0CA73C2380
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 33 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
82DA1330-DBB9-43D6-BAF9-FA55DAF5A601
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 726.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
65ED1B56-34CC-48F1-81AF-71B20A491C88
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found ACEC7EE8-E7E7-4F4D-8481-ED07320975EE
CA26147F-22AF-4CD3-B3B0-1B5207F36E4A
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 866.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C72C2A0A-A691-4CC3-85A7-2EBB25E257A9
CA26147F-22AF-4CD3-B3B0-1B5207F36E4A
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 866.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
17B9D283-6F78-4A8D-A0CC-990DE348DF3E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
E7CBEDAB-69C3-45A7-A3D5-C0F728DB19F1
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 09BEC59D-D492-43E8-85E0-394F7BEF0944
C3F345F6-F2BB-4DCA-8EE6-4BACD56C9553
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 09BEC59D-D492-43E8-85E0-394F7BEF0944
C51E46BF-F581-40BB-8AEC-A03B2C4D70BD
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 5A8D2266-D756-4EE3-9B78-B45383C14CCB
4438C802-559A-4870-81C1-86E265FA5D78
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 879.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 5A8D2266-D756-4EE3-9B78-B45383C14CCB
6F37BAC4-4727-4C67-9905-50B75D23F54B
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 872.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
066830D0-02FE-4B7E-B3D0-A0D3A07842BF
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B2F2F06E-4302-4B89-9C9B-C0DB704A367C
7B3915A2-4E86-4237-909E-8343BB141695
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 704.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found CE568E02-A0A7-472A-8E17-8219D9C19567
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 0C608DA6-3310-40FE-BE53-8DAA2337F78A
73774591-53F5-471B-BCA3-B8DBE070553B
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 380.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
71FDDDA4-89E1-445C-99A7-F0FBA6F6B2EE
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 9CFE7B2B-454F-4213-A906-ED2C3616CA15
859C0BFC-B315-4D57-9424-90E381D489C0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 386.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6443C939-BA0F-4583-AD17-6DF35322A218
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found A8B3F9E3-164F-4779-A235-529A1E135F45
CB7B1D3B-76F7-4477-9968-EF5E1395A644
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1676.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 68374965-673C-4F2A-B6E8-1E2A35BB5D67
CB7B1D3B-76F7-4477-9968-EF5E1395A644
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1676.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
0A840E7D-FE17-48F0-853B-F0354F51F022
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 1FA52551-429C-4FE3-9ADE-6103A6ADD729
8C8E4204-FD56-4C17-A310-8FC4B169C161
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 6772C9AD-A31C-4F13-BDED-9E3B86D17F45
4964FF3A-30AD-4B6E-AD24-9D63D1CD9687
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 6772C9AD-A31C-4F13-BDED-9E3B86D17F45
7FAA0D8B-BCB2-435B-B446-55B339A528BF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 996F345B-F848-4BD6-B9B8-C05B0BA48C0B
B01771F2-C56C-4FAA-B179-0A0293877130
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 996F345B-F848-4BD6-B9B8-C05B0BA48C0B
BC4596AA-E2EC-4951-BE24-17C999455503
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. EB8F8740-1C62-48B6-9391-56EF77C970A7
F499BF06-D470-4C59-A269-2860205CEB62
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. EB8F8740-1C62-48B6-9391-56EF77C970A7
781921F8-16DC-4148-8A36-F1768EB28D13
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. C384AEFB-93B1-4BAF-99FF-9FE8969585A1
623CD3B8-2DDE-48A8-9179-C09E4F2A953F
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. C384AEFB-93B1-4BAF-99FF-9FE8969585A1
8E9C9035-804B-4E3B-9AA4-0FF258D307CB
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 5B81CDC9-D34A-4F23-953F-0A70F4067335
A478FA25-CD9D-45C2-8819-EA1D38999AFE
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 5B81CDC9-D34A-4F23-953F-0A70F4067335
669E2DB9-13EC-41BB-B90B-E1FC1771F01B
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
045857FD-8CC8-4FA5-9198-44108B9D1C7A
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
B905892F-0103-4F20-A36D-E6A79D3E28C3
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. DE88244C-FCFD-4BF4-A5F8-CD84C1391B2E
BF59EB36-FC17-433F-BC47-8F8FEABB62C6
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. DE88244C-FCFD-4BF4-A5F8-CD84C1391B2E
9898D96D-B47E-49F4-B0B5-A17F8E2D18E7
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 8BBE0AD7-9672-431B-A9C0-ECB390DC4FE9
68629880-6514-4640-8892-C9683773A454
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 8BBE0AD7-9672-431B-A9C0-ECB390DC4FE9
CE40D5F0-55E8-406B-AE97-CA63B3382678
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. B55504D3-7F37-454C-944C-446549C20C06
6BF713A5-D26D-4C64-9EBB-49FCDFDF8510
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. B55504D3-7F37-454C-944C-446549C20C06
A9D2C600-B964-41FD-A64F-191BF7954FEB
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 615CD836-586C-4899-A8EC-E5CBF071A8C7
CC020A15-079C-44EB-A5D5-9B9635CEE6E7
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 615CD836-586C-4899-A8EC-E5CBF071A8C7
84D48DB1-0315-4082-9C76-2FC7741E1750
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
AFFBBDDE-73B9-4003-8175-6176D0CB34F8
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 5BC0F009-8178-45A7-B4D4-663CFA94CB76
8CBAB442-DBF1-4C66-B53B-4FFA6E0280BA
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 72D8C652-06C1-4AA6-BDC9-B915F514A9A1
04360B31-EEEE-4164-84AA-258CA6D852E3
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 72D8C652-06C1-4AA6-BDC9-B915F514A9A1
088F9D9A-1CED-4557-969F-0ACA8C2ED545
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
C1948D85-AF84-4861-B057-7FC78370C5F5
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.54 62.6258 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
8B4F079F-D09D-4D0E-BB02-F4A5D9CF735D
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.54 62.6258 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
9A3C04DC-F450-4CE9-A274-EF14EB6B30EC
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
28B9CFF1-406D-439C-8819-E8018BEFA460
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
58A1B05A-7903-43EF-A425-DC709650E9E6
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. AE7BB2C3-935A-48D7-96D5-1121EF0D4258
4504EDC8-3A09-4215-9314-EAB179B09449
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. AE7BB2C3-935A-48D7-96D5-1121EF0D4258
1745BC85-9DE7-4880-85C8-592FA4BB0EDB
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. BD9E7DBE-EC69-49EB-BB12-3F8E102D02D8
F7AF3102-8854-4D06-82F9-F2C5877BF023
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. BD9E7DBE-EC69-49EB-BB12-3F8E102D02D8
32D506C1-860A-4D54-9303-444FABA75B5D
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
C6A484D9-D416-4073-A724-F871B155C244
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
6AC81F90-4F75-4D08-B133-7161F81823E8
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.55 62.5838 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 6625312C-E5BC-4F88-972F-EDDB5B753FC8
A2011AE5-2184-4F99-BE95-9E370D222C1E
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 6625312C-E5BC-4F88-972F-EDDB5B753FC8
1EA58967-EF88-40B2-9089-07D10B2BEF0C
HSS16X8X1/2 W21X93 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 18.31 53.162 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 39575AB0-8076-476E-925A-81523D3C3F60
509C1B55-BB97-481C-9A79-01414B6D73C4
HSS16X8X1/2 HSS16X8X1/2 BEAM_TO_BEAM HSS 0 43.99 0.00 0.00 0.00 16.00 60.8108 0 0 0 0.00 0.00 0.00 0 0 2033.61 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. C59419E9-8972-4BF5-9C20-03A9CDDC97B5
28466171-702E-4572-BCF6-5B4095ED79AF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. C59419E9-8972-4BF5-9C20-03A9CDDC97B5
92E0E35E-D538-4D44-A6B6-BCF4750ABBF2
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
1BD0A2F8-FBB7-4BDB-935A-7802F28440AF
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 0.00 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 5EB74A84-B5D3-4626-94FC-BE97046F3578
F3FAB671-F5DC-4165-8300-1875CBC0E5D8
HSS16X8X1/2 W21X122 BEAM_TO_BEAM NONE 0 42.95 0.00 0.00 1.43 15.48 62.8787 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Supported connection type not found ECB6AA23-46AF-469E-A288-4C6D229D320C
DA2AC3F8-B4D1-45A2-A3FF-4FE6C2706381
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found ECB6AA23-46AF-469E-A288-4C6D229D320C
BDB3FE16-6945-458A-8933-85A218E5D653
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1682.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8AED7CB3-1990-48B2-849C-E530631ED92C
5412E813-E2FA-4985-81FF-6AB33880D03F
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 555.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8AED7CB3-1990-48B2-849C-E530631ED92C
86F09C66-F195-46C4-987A-9346B1F7608C
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 548.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 2DFE2DB3-B007-4F74-9E03-FAD3F1C597E8
DABCDC7E-620B-4F0C-9EDD-D2301FE53B5F
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 542.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found FE9B06A8-5CE8-4ACA-9F29-DC4D84366934
DABCDC7E-620B-4F0C-9EDD-D2301FE53B5F
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 542.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 035E5E9F-6583-48F1-94B6-CEC9EE375D75
34F41067-F048-4FF6-A5F6-771A14541DF9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 542.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 7DB6F78D-008F-4DC2-BC7A-72F695E45D03
EE83B50C-847A-45C1-8EC4-E09D213CC957
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 7DB6F78D-008F-4DC2-BC7A-72F695E45D03
65FB6C5C-7E18-499F-B901-66E1DDA96982
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
01C64280-8BAA-4E7A-82AF-5966A61F003C
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
BE2F0B52-28FF-4142-B5BD-CDD8126F7653
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
2D9130AD-4510-44A0-801A-A9B40200F63F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
C97A5DFC-F1A6-40D5-88FE-41A41A19BE96
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
F697EB99-F1D5-42C9-8713-4D01B659EB10
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
FE9B06A8-5CE8-4ACA-9F29-DC4D84366934
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 564.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
3D16E87C-0E63-4FB4-9A26-87FE602ADB2B
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 98DFB9F3-DAA5-4562-9BA1-7A6F1213151F
6B3D27A1-140A-4C85-8EB0-D3E348B70ADE
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 380.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
9B0E2C9C-B8E5-4C33-9A68-FE2D9B405D16
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 33 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
0C608DA6-3310-40FE-BE53-8DAA2337F78A
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 402.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
3BAFA132-E998-4E83-A9A8-088BBF734FB6
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 110FDB7D-E948-4EE0-A8DB-5F78B2E4CEB9
FC69F2A5-7B66-4A37-B46C-D2EB166EE858
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 110FDB7D-E948-4EE0-A8DB-5F78B2E4CEB9
C645ACDF-CBF4-49CA-BDDB-73A50A41CA39
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 393.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
0571F1DD-D7FB-4E06-9599-FF362E17573E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
1C8D917F-19CA-4C8B-82E0-73668B1F3B50
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
2B830D0D-5244-4BCB-A197-D75F75B6EA64
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
AE661D55-0C27-496D-A36F-9D11085D9593
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
A56ACB7F-DE4A-4F17-8843-A463A3291C8E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 1A9F0913-08EF-46F0-AE77-6CD40D1B3689
668E387A-03FF-49A1-8633-494287969E45
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 1A9F0913-08EF-46F0-AE77-6CD40D1B3689
56AA7C1A-BDED-4946-B631-4A4B2F1F7BE5
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1365.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C7213124-48AA-40CB-B8DD-61160DF07882
3364F58C-2A85-4490-9A89-43F0A313E179
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1352.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 73D4FE4C-6B7E-4FC6-9DD3-1EB6DBCDA25A
3364F58C-2A85-4490-9A89-43F0A313E179
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1352.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 38C8123C-9382-4F62-89A2-F43C2ACE4DAD
04F7C4C1-59B8-4E10-AA17-24920B3B79FE
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1352.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
24F99231-0646-459A-8DEB-9F5A68FC13E3
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
874EA2FE-03B2-40C4-9EAD-C394C8A5E382
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
DBD48ED0-AB5B-41C2-BFFB-B2D37F79AFDC
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
B0AE673A-D765-41E0-B4A7-F04A88E8C666
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
73D4FE4C-6B7E-4FC6-9DD3-1EB6DBCDA25A
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1374.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
90CEF738-9F74-4C30-AC0A-C66B721CB70D
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 33758C8D-DEE0-42C7-9857-E163188E4C4F
D87DF215-2550-472A-B2D9-679A849D59F1
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 33758C8D-DEE0-42C7-9857-E163188E4C4F
E8C34D8B-B6BB-4A26-918D-B164D64C11A8
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found E58A3383-350A-4BAA-8926-F472E1C00DDD
E88B5E59-E8B3-4A7C-B9AA-A9735B1D559E
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1365.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found E58A3383-350A-4BAA-8926-F472E1C00DDD
E4031D49-3511-42EA-A012-EFC26269BFE2
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1358.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
6F8F9D4A-CE65-4795-8D60-0CF84203B0CC
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 4BCF7AAF-F7CF-47A4-846C-5E2B9AC9AE1F
A45BC3F4-DCBE-4D0F-88A3-8A9670C5E792
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 4BCF7AAF-F7CF-47A4-846C-5E2B9AC9AE1F
474A1855-92D5-4B39-BE82-668B65BE022D
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1527.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
1C3665B1-9EB0-4E76-977C-038EE62A6D7E
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
A195001E-5C5E-4E8D-ADE6-6C345637860D
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
B67002EA-0261-4230-ADD3-63C4590893D8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
0457DCC2-4F3D-4961-926B-E88CC6758B95
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 981E3662-7F39-4A6E-844B-57666BCC7635
3502BAFE-BA8B-464D-B6D0-AF989338A829
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1527.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 981E3662-7F39-4A6E-844B-57666BCC7635
D0504C92-D235-4631-BF87-03B9AE455123
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1520.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F24BF273-9D59-45EC-BCE3-42D553D81B06
B94B496E-32E7-44D7-9940-1B2A5823C919
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1514.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
01870393-240A-4DCE-9A6D-29C866AA14B7
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
BF09E36F-D0F0-470A-9955-FFF6BD961210
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1536.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
2D5287EF-1A68-44EB-9C07-3D2B74835D08
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 9ED7B62F-8CF2-4A54-821D-1C08FC0622BB
72C22C63-26E1-416E-9CB9-3091702BBB08
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1514.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found BF09E36F-D0F0-470A-9955-FFF6BD961210
72C22C63-26E1-416E-9CB9-3091702BBB08
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1514.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
3444EC51-F48B-4E72-AD90-32797CFCA793
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
16832A5A-5232-4077-94FA-1AFF62650811
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
3E6E7C1A-F341-43B0-A948-DCDA985BA9B9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
5821C6D0-4886-4FD4-A652-DE1DE25B2E55
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
527086CD-4698-4E1C-B8E6-A4DB576B4ED9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
910EFF2B-04B1-4E77-8A60-B659AF810FB8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found F35F1A5C-B577-43A9-A98C-CFCED0336E9B
B5561713-1D05-406C-BC9C-2547074C83A8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 866.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
90B14FFD-85F1-4AC9-AE6C-3E8A546AF3A0
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
C72C2A0A-A691-4CC3-85A7-2EBB25E257A9
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 888.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
35E0C90C-B657-4477-A0F9-49E698E6DF8C
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found D685F3E4-DBB2-434E-AA60-4A44443B904E
A31F9A03-3BF9-45BD-9D4D-F468B38694D3
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found D685F3E4-DBB2-434E-AA60-4A44443B904E
317C330F-56B1-413D-B5C3-767C5EE23AF1
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 879.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 36938698-4BA9-41BE-917B-A36EB9A0FC7B
A61582FF-4E92-42CC-A7E1-0303A16F334C
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 36938698-4BA9-41BE-917B-A36EB9A0FC7B
FC6D22D0-DA9F-48AD-9B93-B5DE71C616A6
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found CAC614D6-3930-484F-9374-2165D64F88CF
C10C402F-F9B9-414F-BF73-9C4E42A5B8E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1041.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found CAC614D6-3930-484F-9374-2165D64F88CF
60298E80-7C71-44BB-AA04-8BCB0B4D7B17
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1034.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
F9D1D7F0-91A1-4BD2-8B22-567189A43574
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
B8C2A21D-70E3-497D-AAA5-49E1CACEDA37
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1050.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
39E40769-ADCF-4156-A4B9-F3374555D34D
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 57578118-5DED-465C-8EB1-C8D1958EA3E8
4220FC9B-2BA6-4C93-BE06-3D34A5946ECE
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1028.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B8C2A21D-70E3-497D-AAA5-49E1CACEDA37
4220FC9B-2BA6-4C93-BE06-3D34A5946ECE
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1028.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
D02A7757-F456-43A0-B59C-B93DCC19A86B
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
61D4E711-4FD5-4186-A4E3-CFD5C8A639C6
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
74310FA7-D4E9-4517-965D-DB61F51CBD12
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 51BA6D0D-66C8-4B79-9BBB-B9BF56E39A4C
1AEFBAB5-F3AA-4B0B-8600-A3F6B3EF173F
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 51BA6D0D-66C8-4B79-9BBB-B9BF56E39A4C
4E21892F-B6A4-4DCC-9F2A-9E5B9C687224
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1203.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found ACA670B3-1EC5-4084-9B6A-E01562621B83
B9213A9D-DB05-408D-BE45-4DA9572D3712
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found ACA670B3-1EC5-4084-9B6A-E01562621B83
276B19D4-38A7-4793-AAA1-2D63619FDF9B
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1041.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
AEB73A92-1F8B-41BB-8C02-EA917305324B
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
7F0E6AD2-5981-48AB-AEFC-FD4C32B58530
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1212.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
7FDD9D51-1633-4172-91DA-BEF3BC95E365
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
E96BB49F-6910-4A35-8DCA-EAA699AD4977
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
C4FAC400-9543-4B25-8057-1A6BD4896836
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
FFC21D70-D788-4D4E-8A2A-C03B634BB7D9
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found FA9FDE01-F63B-405C-89A6-EB5EEC187131
144D2F6D-5C1E-4F9A-9710-4D74C63134EA
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
2A18F2B2-1E72-4FF2-95BC-6ABDD3074436
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1190.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 7F0E6AD2-5981-48AB-AEFC-FD4C32B58530
2A18F2B2-1E72-4FF2-95BC-6ABDD3074436
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 1190.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B3A085F3-F2E5-4967-88F3-D9CB1B563ACB
11EE248B-4BB8-45B9-A582-84EA198C8FD8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1190.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C0139783-4A96-4DFD-BC58-47B07868F60A
873E4496-E6AB-4C12-8905-D05CD4E58F7F
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C0139783-4A96-4DFD-BC58-47B07868F60A
5864D340-9DDE-400A-8297-FB64DB071ED1
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 4778A2A0-A24B-4576-A05F-6455A86A3E86
083F3028-0C75-4E10-BC6C-B6C1C5A8937A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1203.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 4778A2A0-A24B-4576-A05F-6455A86A3E86
F19B8712-1AFA-4F4D-B854-9E9E20B18CE0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1196.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. DD10C239-456B-42DE-8ECB-76ADE840A197
3469D7EF-A378-4DD2-9B4E-81ED9840DB64
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
9216A95C-39D8-4394-A7B7-D2065F6D9E5F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. E0B08B4B-BC81-4005-AAC6-417BF00C352B
688A86B8-2381-46D6-A25D-D5B51C8C2797
W16X26 W21X50 BEAM_TO_BEAM NONE 0 -0.96 83.00 -2.64 0.00 12.38 35.6335 0 0 0 0.00 0.00 0.00 0 0 12.985 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
E46D4443-4EE3-40CE-A6A8-A53E76993D59
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 04B80C17-61F5-435A-85FA-1EAA2130B089
8A552244-D392-4D59-B67A-E653D5CA4C50
W8X10 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.64 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 2.61262 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. 0CD686BD-D8D9-4987-A7F0-569583C5C2C8
ED1C1A21-79A0-4CC0-8B0B-FCE7C2B8DE91
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.86 83.01 -6.06 0.00 15.39 13 0 0 0 0.00 0.00 0.00 0 0 6.56707 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 0CD686BD-D8D9-4987-A7F0-569583C5C2C8
4903CA7E-E6AD-4343-AC38-7B6167850BB1
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.03 0.00 44.94 33 0 0 0 0.00 0.00 0.00 0 0 15.6509 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 98BA463C-687B-46FB-8CE4-D5699B97A882
1E6A7B70-E773-4D07-84EF-18E10E3114B9
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 1.67 0.00 45.00 37 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
E04120CC-0459-4255-B85D-4C65CA61E872
W8X15 W40X167 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.50 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found DFDB1767-0816-4897-85BF-BD729573A8A0
E04120CC-0459-4255-B85D-4C65CA61E872
W8X15 W40X149 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.13 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
8F138495-EC97-4145-AE55-72D8AA4FB1AE
W8X15 W40X167 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.50 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found DFDB1767-0816-4897-85BF-BD729573A8A0
8F138495-EC97-4145-AE55-72D8AA4FB1AE
W8X15 W40X149 BEAM_TO_BEAM NONE 0 0.00 90.00 -30.13 0.00 9.50 15 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. B42E0558-18D9-4C70-8132-288D5DAE0E56
C8457151-2FA7-4126-A970-0F262F0199F8
W18X35 W14X22 BEAM_TO_BEAM NONE 0 0.00 -83.09 4.00 0.00 3.51 189.042 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 37D52133-8A74-4741-922F-B00B51799C54
6EF1C0C9-B8C1-4CF2-AFEA-14C05C76E5B8
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 37D52133-8A74-4741-922F-B00B51799C54
49F12458-B474-43E1-BCF7-D75F441EE50E
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
B6F414E4-B7A7-46EE-A141-9B5F17F4A126
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
FF7A9395-D400-47A7-8098-A26BD6B77104
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
7FEAA7D1-8B13-4323-A9A9-61145FF35CD8
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 2182E459-9C3A-47D3-9580-8F82E2C63060
1A488E75-E700-4CCF-96D5-2CDE648BC4F5
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 1676.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
3445C3F2-BACD-4EAD-88E7-ED1AF860A921
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
A8B3F9E3-164F-4779-A235-529A1E135F45
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1698.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
A779A281-E3BC-4125-A535-E6289CB3F459
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found DC6DB2A9-3885-4421-B0E3-E96E06A3292C
59A05F6D-79C8-4822-B3D4-9C3771A73A58
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found DC6DB2A9-3885-4421-B0E3-E96E06A3292C
5D2155DF-F903-47F5-8117-90FFA45107C6
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found D731B8AB-F16E-4E58-8CF8-9D461F1801BF
67BFA688-A1F6-415F-BCF0-F7362C79DD89
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 231.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found D731B8AB-F16E-4E58-8CF8-9D461F1801BF
F1459467-8D71-4890-AB76-0C235866B4F0
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 224.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found D0D59AF9-4838-4A07-9619-2715740F8C0C
C9FC156E-5435-45E4-B3AA-EEC60787CBDB
W8X18 W30X116 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.88 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 218.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found D5B94786-A91C-4967-982E-220EF3465CED
C9FC156E-5435-45E4-B3AA-EEC60787CBDB
W8X18 W30X108 BEAM_TO_BEAM NONE 0 0.00 -90.00 -21.75 0.00 9.86 15 0 0 0 0.00 0.00 0.00 0 0 218.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E8847A70-26EE-4F36-9DD4-E5D72960DFF1
C8457151-2FA7-4126-A970-0F262F0199F8
W18X35 W18X35 BEAM_TO_BEAM NONE 0 0.00 -83.09 0.00 0.07 3.51 189.042 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E8847A70-26EE-4F36-9DD4-E5D72960DFF1
B8C27D76-6DC1-4E0A-A4CA-D0D29A8D3CCA
W18X35 W18X35 BEAM_TO_BEAM NONE 0 0.00 -83.02 0.00 0.00 19.88 11 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
1B6BF262-F900-4B02-95CD-DD60792C309F
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. DFDB1767-0816-4897-85BF-BD729573A8A0
B5257666-8BDF-4CB1-B5B5-2FE0F1608142
W8X10 W40X149 BEAM_TO_BEAM NONE 0 0.00 -90.00 -30.38 0.00 5.63 15 0 0 0 0.00 0.00 0.00 0 0 2018.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
3E81227F-89E2-48F3-A9E8-76C9CAC23401
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -6.00 0.00 10.65 17 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
A84E7E56-49D9-425D-9A4A-F21BECA72F79
W21X62 W18X40 BEAM_TO_BEAM NONE 0 0.00 -84.50 3.12 0.00 22.93 35 0 0 0 0.00 0.00 0.00 0 0 1852 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. CEDE7528-6B1F-4D50-850A-9A5102A35EBC
181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
W18X40 W21X55 BEAM_TO_BEAM NONE 0 0.00 84.49 -2.88 0.00 33.10 34 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. B5FD41EE-69F7-43EC-9B98-53F5E766BC4C
5880CE72-5088-4AC8-BB70-5ABD1DE92D1A
W12X14 W40X167 BEAM_TO_BEAM NONE 0 0.00 -90.00 -26.75 0.00 6.04 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8E614244-7AF7-4A01-B44A-D5C5B158C354
5EF07686-B1FA-445D-8F9D-097EDA5F62FB
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.88 0.00 45.00 40 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8E614244-7AF7-4A01-B44A-D5C5B158C354
4D788503-5989-4F67-92E6-83A453F14569
W16X26 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.13 0.00 24.05 27 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. F614BD41-ACF5-4D7A-BA1A-6EAE5E242BFC
EB0A5650-5372-4B64-95AC-FC05B4CCD970
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 10.23 30 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. F614BD41-ACF5-4D7A-BA1A-6EAE5E242BFC
AA230C34-B299-4560-A4AD-F18C88234A2E
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -88.61 2.00 0.00 20.03 13 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. AA230C34-B299-4560-A4AD-F18C88234A2E
DA837A15-17E7-474D-8AEB-C78E6E5123D4
W16X31 W18X35 BEAM_TO_BEAM NONE 0 0.00 88.61 -1.88 0.00 3.93 137.136 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. AA230C34-B299-4560-A4AD-F18C88234A2E
05CC3659-5B33-490F-A674-98B9FEE33018
W16X31 W18X35 BEAM_TO_BEAM NONE 0 0.00 88.61 -1.88 0.00 35.84 15.0378 0 0 0 0.00 0.00 0.00 0 0 2284.37 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 9653A074-7541-48AF-AE0C-04A23F47DA27
3469D7EF-A378-4DD2-9B4E-81ED9840DB64
W14X22 W10X12 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 62FDF846-535A-4AA7-8554-D2F2C04F3267
9653A074-7541-48AF-AE0C-04A23F47DA27
W10X12 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.88 0.00 10.00 20 0 0 0 0.00 0.00 0.00 0 0 2278.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. E3990C09-536C-417B-B9E9-D92B585C9D73
077A8702-D39A-4573-BF04-B671CAC7F09C
W14X22 W18X35 BEAM_TO_BEAM NONE 0 -0.90 -83.00 -1.83 0.00 11.65 30 0 0 0 0.00 0.00 0.00 0 0 2192.42 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. 6A53AD67-6333-455B-9F59-0F2226A0B78B
077A8702-D39A-4573-BF04-B671CAC7F09C
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.90 -83.00 0.00 0.00 11.65 30 0 0 0 0.00 0.00 0.00 0 0 2190.2 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found E8A24FF6-D411-44C7-892A-FA1889F00148
99258A7A-0375-4955-8AD1-40235B3F4D91
W21X55 W21X48 BEAM_TO_BEAM NONE 0 0.00 90.00 0.13 0.00 45.00 51 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found E8A24FF6-D411-44C7-892A-FA1889F00148
A2B1A411-789E-4F1A-AFC3-123CD3E9B0F5
W18X40 W21X48 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.75 0.00 34.90 38 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
9C51C74D-F5A7-415F-9C4E-37D8F0B1D5A1
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
0542B7B5-89B7-4B84-9C92-9888D6C9A966
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
12F39FB7-FCEF-4F22-815A-BD027E380E53
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 -90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found C45187F3-1794-4D87-AE0D-834E2917BEA1
C0CB8698-7ED5-4EF1-B390-EDFC8E7735D5
W8X10 W21X101 BEAM_TO_BEAM NONE 0 0.00 90.00 -13.50 0.00 10.00 15 0 0 0 0.00 0.00 0.00 0 0 218.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 290C7D84-5C46-41F5-A6FD-8B8501FAD362
77E41864-354F-49AA-9333-A1F07AA779E4
W18X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 0.12 0.00 32.38 25 0 0 0 0.00 0.00 0.00 0 0 1848.87 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. 67B642D8-87C2-45AE-80D0-CCC5901103AE
290C7D84-5C46-41F5-A6FD-8B8501FAD362
W18X35 W21X201 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.25 0.00 10.00 66.3834 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 1F15AD9A-5A71-4CE6-9828-DA0D947A6915
06E2CFCC-7D25-4E64-8D50-3A3A180CB582
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.03 0.00 44.90 33 0 0 0 0.00 0.00 0.00 0 0 15.6509 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. 1F15AD9A-5A71-4CE6-9828-DA0D947A6915
83E58AC3-D197-4030-960B-1CA3BB154A00
W12X14 W18X40 BEAM_TO_BEAM NONE 0 1.03 83.00 -6.07 0.00 12.99 11 0 0 0 0.00 0.00 0.00 0 0 6.5562 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. 705D515C-E499-4482-A35F-A4BB13F49404
40CE5947-F5CD-46DF-AEE0-046EA836D0C0
W12X14 W18X40 BEAM_TO_BEAM NONE 0 1.17 83.00 -6.08 0.00 10.60 25 0 0 0 0.00 0.00 0.00 0 0 6.54677 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 705D515C-E499-4482-A35F-A4BB13F49404
598F64BB-7501-4831-8B36-1C12FB2C40E8
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 44.92 33 0 0 0 0.00 0.00 0.00 0 0 15.6248 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 90686697-E1FE-4886-8998-19A5F135BE4B
09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.63 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 12.624 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 09D36DDA-23B8-4D8D-9B1E-FC4F4FBEB246
BE049090-A57C-4C73-A746-05B575DA6701
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.98 0.00 45.00 32 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8B36CDC3-2492-42CC-BDA9-7969886A81E0
8A72BC96-3E03-419F-830C-87524A0B7564
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 34.83 26 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 8B36CDC3-2492-42CC-BDA9-7969886A81E0
B72C4284-5819-4764-929C-560F75E2C85D
W21X50 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.25 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 231.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
0D9E4A9E-DE97-4127-BCCB-8F4F5C561506
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
D0D59AF9-4838-4A07-9619-2715740F8C0C
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 240.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
C0A7913B-9597-4B2F-AE0D-392C249E35E6
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 83.01 -11.75 0.00 15.32 13 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. A40D0707-CB63-494F-B78F-83BF153E7098
15CBF671-1A7F-48E0-A322-40A3772FB251
W14X22 W12X16 BEAM_TO_BEAM NONE 0 0.00 -90.00 1.75 0.00 20.13 16.464 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. FE52CDED-369B-4256-AA0A-3DACCB1205F5
A40D0707-CB63-494F-B78F-83BF153E7098
W12X16 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.75 0.00 23.98 8.36555 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
A07C5B85-BC0F-4A88-B230-F16391582374
W18X35 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.00 0.00 36.94 20 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
90C93110-BFCC-4941-9EE0-1AEE00CCCF40
W12X14 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
0FC65D40-AF42-4477-8454-4987A20902E9
W21X44 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.75 6.00 28.94 25 0 0 0 0.00 0.00 0.00 0 0 2031.37 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. C749928F-1D16-4111-85ED-C65C8A54C1D7
DDA37837-B098-4927-B57D-C9D43D6E426D
W12X14 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -6.00 0.00 10.68 17 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 97E1E225-1274-49B4-96F0-9C15B10FE79A
4877E884-471D-4F45-8222-520CF12C4AAD
W12X16 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 -5.75 0.00 10.68 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 97E1E225-1274-49B4-96F0-9C15B10FE79A
61C66E6D-542E-4BF3-9658-90E04ECE8007
W21X44 W18X35 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.88 0.00 36.94 31 0 0 0 0.00 0.00 0.00 0 0 2031.37 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 3179739E-F7B7-4E7E-AC14-C1C6A351F7FA
D48B9EE2-BA8C-440F-86B8-335673D9AD8A
W21X50 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.00 0.00 45.00 36 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 3179739E-F7B7-4E7E-AC14-C1C6A351F7FA
9D1687C6-9FB1-4150-B96F-912EECF9E030
W14X22 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -4.13 0.00 24.05 22 0 0 0 0.00 0.00 0.00 0 0 1844.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 775F59CC-D207-424C-943C-45AD46BDA2C0
AB612E15-8AC9-46E8-9928-FF22A75103C0
W16X26 W21X44 BEAM_TO_BEAM NONE 0 0.00 83.01 -4.88 0.00 15.33 16 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
D609A66D-9839-42BC-92F6-58A3E24E5425
W21X55 W21X83 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.63 0.00 45.00 51 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
704847F5-1E77-4AC8-81D5-37A5BB35BFE0
W18X35 W21X83 BEAM_TO_BEAM NONE 0 0.00 88.05 -3.63 0.00 36.00 37 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
E8A24FF6-D411-44C7-892A-FA1889F00148
W21X48 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 44 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
00D94FA7-CFDE-4CDD-AC5A-6AE0166249D2
W12X16 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
827C55CB-7061-4844-ACF5-05A59FB1CBCA
W16X26 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 29.00 19 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. B50EB32B-3D8D-4945-8CE9-CA3A09181C22
5E8847C6-3429-41E4-83AB-50CC44966987
W14X43 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections to a girder where there is a column flange above or below are not supported yet. E7EC1C34-E0C9-4388-A987-906874F4FE8A
B50EB32B-3D8D-4945-8CE9-CA3A09181C22
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 19.94 16.6145 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 68E06054-293C-4849-BE0D-A5697055AF9F
69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
W18X35 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.25 0.00 20.00 35 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 68E06054-293C-4849-BE0D-A5697055AF9F
FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
41CD1199-5009-48D1-A5A3-FF28C3976D73
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
181DCF30-7E16-48EF-A3FD-D4B66B12A5A1
W18X40 W18X46 BEAM_TO_BEAM NONE 0 0.00 -79.50 -0.13 0.00 33.10 31 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
C4BF2FC5-B3E0-4AC0-995E-51F2D054DEB5
W16X31 W18X46 BEAM_TO_BEAM NONE 0 0.00 -79.50 -2.13 0.00 30.44 24 0 0 0 0.00 0.00 0.00 0 0 1846.87 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. F7041EBC-0A5F-41C2-A893-054BBEC2EA04
5D257874-B649-4E3D-B083-C64788065277
W14X48 W18X46 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1849 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
FE558B1F-EE89-4F79-9626-4DD52CF1E3BA
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
W18X60 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.75 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
4E134221-1035-49CA-B35E-A781B5D4DEBA
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. FD3D037D-5494-438B-9070-EDDC0EA5C82B
26E1EE41-9A11-4EEE-9339-250EB4E1E041
W14X43 W21X111 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2032.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
W18X35 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 20.00 35 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
C276519D-931D-4557-A516-97AAA2C95482
W18X35 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 69497B8D-D3E0-4439-8F75-ACBB2A54C9E3
AC8034FB-ABF2-4728-8CC7-4E64639E9A9B
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 56148724-7135-4712-B68F-305F3B27138C
F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 56148724-7135-4712-B68F-305F3B27138C
9CEB8268-1533-4B64-8788-FE214DA33696
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 34 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 9CEB8268-1533-4B64-8788-FE214DA33696
24DB69A2-3F16-4127-85BA-1827873B72C4
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 213A3419-B118-497F-B4ED-EF9E22803A70
DA3A0C2D-E764-4BC9-8723-5B11909E3C86
W18X35 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 32.52 18 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. DA3A0C2D-E764-4BC9-8723-5B11909E3C86
8CC17800-B31A-4419-9B5E-B83A51B6C175
W18X40 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 0.13 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. DA3A0C2D-E764-4BC9-8723-5B11909E3C86
06A762CD-6FFA-4D78-8266-515E368F9689
W14X61 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
F8A51DB3-7C7F-4902-B159-1D423CDA90B9
W21X68 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 0.50 0.00 20.00 20 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 628C0350-A369-48A2-99B0-7FE05F1B8B72
E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
W21X44 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.50 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 628C0350-A369-48A2-99B0-7FE05F1B8B72
2E59BE03-0547-48CE-8014-6690D872C9C7
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. DADA8014-282F-4963-9986-BCFC63188B6F
DA8352A9-E9A4-434F-9E54-A9F6605549E0
W21X44 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 8.50 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. DA8352A9-E9A4-434F-9E54-A9F6605549E0
712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
W21X55 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.13 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
64AE8F49-4E1E-4611-939D-C22BF7153D67
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. E9A78B79-3D01-4A06-B0BD-679CD2D5AB65
DADA8014-282F-4963-9986-BCFC63188B6F
W12X19 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -8.50 0.00 20.00 11 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 3E7EE27E-60E7-4496-AF67-6DA72A755BA5
06EFA10C-AC85-48E2-BB76-4CDD620AB53F
W14X68 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 37D52133-8A74-4741-922F-B00B51799C54
69BF29A6-1BF7-4491-8DED-14279ABDF205
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 88.05 -2.88 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1686.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 786212BB-2A21-4285-8839-203B1E887441
313E3F6D-87A2-4330-8BD4-7291B3E9511D
W14X90 W21X50 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 36.06 0 0 0 0 0.00 0.00 0.00 0 0 1689.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 786212BB-2A21-4285-8839-203B1E887441
37D52133-8A74-4741-922F-B00B51799C54
W21X44 W21X50 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.25 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1689.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 786212BB-2A21-4285-8839-203B1E887441
C2FE6BF7-F3CB-4951-A189-0B9928695D8A
W18X40 W21X50 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.00 0.00 20.00 29 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. D9774C64-813D-425A-921B-5050D603A4BC
BBCA9207-8685-48F3-BD48-5586F1327BAE
W14X48 W21X93 COLUMN_TO_BEAM BELOW 0 -90.00 -7.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. D9774C64-813D-425A-921B-5050D603A4BC
B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
W18X60 W21X93 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.38 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. B6CD8FD7-6E32-4B5F-8B90-5E21D09AE9FC
6E81C378-9254-4005-87E7-E622140A8BD9
W14X109 W18X60 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2029 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
5E8847C6-3429-41E4-83AB-50CC44966987
W14X43 W21X55 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 1281E5CB-B4F0-449C-9E64-513FC966FD48
68E06054-293C-4849-BE0D-A5697055AF9F
W18X119 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 1.13 0.00 45.00 65 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 68E06054-293C-4849-BE0D-A5697055AF9F
2ECEC8F6-06D2-496F-8E27-AFEF34276840
W14X43 W18X119 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 338638BA-B2D9-4CA4-9AC1-2EBE0423FC15
1281E5CB-B4F0-449C-9E64-513FC966FD48
W18X40 W12X16 BEAM_TO_BEAM NONE 0 0.00 -83.02 5.88 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. FC07D5E4-4C1C-4879-AD88-0F9340F1CE4E
338638BA-B2D9-4CA4-9AC1-2EBE0423FC15
W12X16 W18X40 BEAM_TO_BEAM NONE 0 0.00 83.02 -5.88 0.00 11.73 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 628C0350-A369-48A2-99B0-7FE05F1B8B72
A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
W18X40 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.25 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
45B3614A-E04B-4F6A-9E54-7097C38E26A8
W21X68 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 3.25 0.00 20.00 20 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 45B3614A-E04B-4F6A-9E54-7097C38E26A8
ED50100C-D93B-43EB-972A-70EDBA07BF0E
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. C0F54A76-A2F7-47C9-8320-E638CBB91E0C
9DBA1190-D366-4F39-9406-FCE8BDDB6335
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 19.94 16.6145 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 9DBA1190-D366-4F39-9406-FCE8BDDB6335
9A43B315-F54F-4EE0-819F-F5748C979535
W14X53 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections to a girder where there is a column flange above or below are not supported yet. 9DBA1190-D366-4F39-9406-FCE8BDDB6335
E7EC1C34-E0C9-4388-A987-906874F4FE8A
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. DADA8014-282F-4963-9986-BCFC63188B6F
6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. E8607EB6-0BF5-4218-9C92-8EE0225AA17A
9CE6EB0B-EAF3-4FF6-873D-BD8DB74FD3B6
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
DADA8014-282F-4963-9986-BCFC63188B6F
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 11 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. A0BB4E66-6BE1-4C8C-B0C4-937E2F674BE8
E8607EB6-0BF5-4218-9C92-8EE0225AA17A
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.88 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. F8A51DB3-7C7F-4902-B159-1D423CDA90B9
AE197D6F-29DB-4952-8FA8-91DB5DCFD553
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
09896AA6-F981-4407-97DA-8004F60E7937
W16X31 W21X68 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.25 0.00 9.44 57.1044 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
58EADA83-DB44-4FE6-85FC-510747343AEB
W16X31 W21X68 BEAM_TO_BEAM NONE 0 0.00 90.00 -5.25 0.00 2.82 191.34 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 58EADA83-DB44-4FE6-85FC-510747343AEB
08410363-4CB8-4991-8A55-247E3759DB6D
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.46 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 1F600D7F-4C5E-495A-86ED-F28C923A50ED
6D23561F-58EC-4295-BEE5-00A1A2EB6173
W14X53 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 6.98 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
FC07D5E4-4C1C-4879-AD88-0F9340F1CE4E
W18X40 W18X119 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.13 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 775F59CC-D207-424C-943C-45AD46BDA2C0
1F600D7F-4C5E-495A-86ED-F28C923A50ED
W14X22 W21X44 BEAM_TO_BEAM NONE 0 0.00 83.03 -6.88 0.00 14.17 15 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. 775F59CC-D207-424C-943C-45AD46BDA2C0
3F47254E-E617-4C19-8ADF-CE741A29D5DA
W18X119 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -1.63 0.00 45.00 63 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. E38F5BF5-B3F9-476A-8BF8-011B1208C40A
5AC22012-EAB4-48C9-BAC5-A63A7755EF44
W21X68 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 5.25 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 5AC22012-EAB4-48C9-BAC5-A63A7755EF44
D2EF0942-F263-4253-BC4B-B59575638260
W14X90 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections to a girder where there is a column flange above or below are not supported yet. 6815E598-889F-410D-A199-6334C0E62A0F
9D406AB8-1B78-4133-BDDA-799B127C0192
W21X44 W18X40 BEAM_TO_BEAM NONE 0 0.00 82.89 2.75 0.00 26.98 47 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 9D406AB8-1B78-4133-BDDA-799B127C0192
709627D5-9623-4FCF-A0B4-AF1FA3793033
W14X43 W21X44 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 62FDF846-535A-4AA7-8554-D2F2C04F3267
C0F54A76-A2F7-47C9-8320-E638CBB91E0C
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 10.00 30 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 62FDF846-535A-4AA7-8554-D2F2C04F3267
380C0450-E673-4C3A-B6DB-9B8B15560968
HSS16X8X1/2 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 2.25 0.00 17.50 55.6145 0 0 0 0.00 0.00 0.00 0 0 2284.5 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. 380C0450-E673-4C3A-B6DB-9B8B15560968
061CD475-F454-4C42-AC1E-79DCE10446B7
W14X61 HSS16X8X1/2 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
061CD475-F454-4C42-AC1E-79DCE10446B7
W14X61 W21X68 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
83C2ABD3-24A6-4CEB-B831-12BFF1CB9BB8
W12X16 W21X83 BEAM_TO_BEAM NONE 0 0.00 83.01 -9.38 0.00 9.24 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
5ECD8C65-D571-41AE-9B29-6CCAF5D05E07
W21X83 W21X111 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.13 0.00 20.00 60 0 0 0 0.00 0.00 0.00 0 0 2032.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. FD3D037D-5494-438B-9070-EDDC0EA5C82B
FEF4C8EC-BDB4-4327-BDFC-291A69AB5C22
W14X61 W21X111 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2032.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. FD3D037D-5494-438B-9070-EDDC0EA5C82B
1281E5CB-B4F0-449C-9E64-513FC966FD48
W18X40 W21X111 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.63 0.00 20.00 31 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. E8607EB6-0BF5-4218-9C92-8EE0225AA17A
D7D680D6-D0E7-4A17-AB9D-EEE8EB5A95A7
W14X61 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 66445B1E-7A02-42C3-A9DF-234872A5B7DF
45586449-08E6-46AC-9C1F-F1730B8F8C85
W14X53 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
66445B1E-7A02-42C3-A9DF-234872A5B7DF
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
9653A074-7541-48AF-AE0C-04A23F47DA27
W10X12 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.88 0.00 10.00 20 0 0 0 0.00 0.00 0.00 0 0 2278.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. DD10C239-456B-42DE-8ECB-76ADE840A197
E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
W14X61 W16X26 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. DD10C239-456B-42DE-8ECB-76ADE840A197
C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 -2.00 0.00 19.93 16.6231 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. C5A1B326-352C-4ACE-BEC8-38E4DD74DA41
98550496-1EAE-45E3-877C-94C5CF156DE9
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 98550496-1EAE-45E3-877C-94C5CF156DE9
0693463D-E958-47A2-8A6E-6A157F3D5270
W16X26 W14X22 BEAM_TO_BEAM NONE 0 0.00 -67.00 2.00 0.00 21.65 14 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
5733EEB6-E12F-48BF-8369-B6EFB5E40790
W14X43 W21X62 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
8D62A7F1-4DC9-4CFF-8F89-72AA203C5B98
W14X145 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
W21X44 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 39 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
F16F62A7-7E7D-4653-B4DF-E4926C59E7C1
W18X35 W21X44 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.88 0.00 31.21 27 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 9D79DD74-29D9-4233-B923-BC24FA2C5CD3
3058B5D6-FE1D-4DC4-8753-07ED34D79B67
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 248161F1-985E-4AC8-BB3C-80AFE7593D46
9D79DD74-29D9-4233-B923-BC24FA2C5CD3
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 3058B5D6-FE1D-4DC4-8753-07ED34D79B67
55C3B4D4-4080-4C0B-8975-98E30CF1B29E
W21X62 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 3.13 0.00 45.00 56 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
D3FCA134-870E-489A-85DE-89BC970A0259
W14X61 W21X62 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 55C3B4D4-4080-4C0B-8975-98E30CF1B29E
3449F51F-9875-41AF-B0EB-CC4113E034DE
W14X61 W21X62 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 56148724-7135-4712-B68F-305F3B27138C
7BF637B5-4B36-482F-AC76-9F1D4103CF01
W14X90 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 56148724-7135-4712-B68F-305F3B27138C
E8A24FF6-D411-44C7-892A-FA1889F00148
W21X48 W21X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -0.13 0.00 20.00 44 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Filler beam workpoint is not between support end points. 56148724-7135-4712-B68F-305F3B27138C
9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
W21X44 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -0.13 0.00 20.00 39 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Filler beam workpoint is not between support end points. 9F6B0ED0-66EA-40EC-B8EF-FF06DC0AEC9A
E565E1A1-4654-4BE3-8633-7DF48C63EF26
W16X36 W21X44 BEAM_TO_BEAM NONE 0 0.00 -88.40 -4.75 0.00 33.80 38 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 33E6BC41-0C99-44B6-B465-0AA2D6135BA6
3058B5D6-FE1D-4DC4-8753-07ED34D79B67
W18X40 W12X19 BEAM_TO_BEAM NONE 0 0.00 90.00 5.75 0.00 20.00 32 0 0 0 0.00 0.00 0.00 0 0 2028.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
33E6BC41-0C99-44B6-B465-0AA2D6135BA6
W12X19 W18X40 BEAM_TO_BEAM NONE 0 0.00 -90.00 -5.75 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 6555BAB7-1446-4A2F-8BBB-02F3ECF1AD97
92D20A49-A600-4E40-9E2C-F6632FE8BD3B
W21X55 W18X40 BEAM_TO_BEAM NONE 0 0.00 90.00 2.88 0.00 45.00 47 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
F2043603-D371-4973-9114-1C5BA5270DA0
W14X53 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. DA24DB18-6A90-4E73-B417-15AFA2D6459C
839A1792-276B-4D50-9709-4BB23AA90A8C
W14X43 W24X94 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
E51E3C2A-5BB4-4822-9DE9-C2A7C008F9F3
W14X61 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. DD10C239-456B-42DE-8ECB-76ADE840A197
99BFD3F8-9C08-4097-818C-EDF0A9F0806F
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. DD10C239-456B-42DE-8ECB-76ADE840A197
FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
HSS16X8X1/2 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.25 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
46022672-A263-41E3-BE1B-5233A95442D7
W14X43 HSS16X8X1/2 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 0169F8F2-6ADA-48AE-8C4C-4FE86A105E05
46022672-A263-41E3-BE1B-5233A95442D7
W14X43 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 92D20A49-A600-4E40-9E2C-F6632FE8BD3B
D0BF0B8B-C43A-4741-989E-6BB05970F7FB
W14X61 W21X55 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. 98550496-1EAE-45E3-877C-94C5CF156DE9
FE52CDED-369B-4256-AA0A-3DACCB1205F5
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections to a girder where there is a column flange above or below are not supported yet. D83E7D92-5F8D-4E00-AE97-1C88E941B14D
98550496-1EAE-45E3-877C-94C5CF156DE9
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 -90.00 0.00 0.00 32.48 10.2015 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. FE52CDED-369B-4256-AA0A-3DACCB1205F5
8D380BA7-470A-46EB-AC04-0B346404ABEE
W14X61 W14X22 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 21.48 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 71DEE630-6CEF-42ED-A93D-8FFD7E27B01A
BCA24E27-99E9-4C19-91AD-8602025D509F
W14X120 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 1F023FF4-695C-42CC-8A12-C825D216A4C8
28F7B09A-AAF8-4FA1-9B99-E55D7C669C39
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. C733972F-E1F6-4272-A287-DB3F2FACF0E0
C9EEF9BF-E989-4DFC-9F93-C24FA7734139
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.875 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. E8FFA5E5-A849-4BD3-99D1-CE641157E4F4
2A73A730-ED7A-4253-B03D-ECE82218B54D
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.94161 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. 380C0450-E673-4C3A-B6DB-9B8B15560968
12271B2D-328A-4980-9C13-72EC0ED7C824
HSS16X8X1/2 HSS16X8X1/2 BEAM_TO_BEAM HSS 0 0.00 90.00 0.00 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. 12271B2D-328A-4980-9C13-72EC0ED7C824
B702B89D-A7C0-4D3A-937D-BCB51C5B7934
HSS14X14X3/8 HSS16X8X1/2 COLUMN_TO_BEAM BELOW 0 -90.00 -90.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
B702B89D-A7C0-4D3A-937D-BCB51C5B7934
HSS14X14X3/8 W21X68 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 9BD7CF86-7C35-4F19-B138-5F71ED3BEC54
1E02AB57-37E5-4ED0-8607-9482A69F05FB
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.39 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
8BA0FDD2-A9DC-4EBE-A84E-23BB3DACE0E2
HSS5X5X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. AE11B7E1-DD01-4CF9-8590-E0107AD83279
27F45B62-0967-4B30-BEA7-86FB2A0B63B3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.94161 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. AE11B7E1-DD01-4CF9-8590-E0107AD83279
B5C69C86-7BB2-4A34-93BC-8EF507044ECE
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.96401 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. E0B08B4B-BC81-4005-AAC6-417BF00C352B
1A7E56F8-6FF5-4621-B2E4-C14BAD41C75B
HSS6X4X3/8 W21X50 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.47 0 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 1F023FF4-695C-42CC-8A12-C825D216A4C8
7C2ED840-1EDA-4D65-B6AC-2048B239B59A
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. A378805D-EF66-4E95-A394-22742217D921
EF44D347-1114-425F-9294-B21DF9CD3489
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 95EB7118-8314-4E74-B818-CE6EF4153278
0C9E4ABC-4B3D-4057-9A7D-CB892D4350FE
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 95EB7118-8314-4E74-B818-CE6EF4153278
9FA14F1A-28C6-4780-99FE-A91C7DC4968A
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. A378805D-EF66-4E95-A394-22742217D921
72D0F3B9-B576-431E-9986-7C9B789A3E10
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 13.76 0 0 0 0 0.00 0.00 0.00 0 0 1839.13 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 5BA9D70E-D611-46DB-BFA4-A222377D4379
83422ED1-126B-43BB-8E34-1F4606FEBFFB
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 20.92 0 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Beam to Column connections in a group with Column to Beam are not supported yet. AD312723-CCB1-4725-ADB7-8CDEA41E5FB1
E4E53C55-C050-4153-B4DE-EF10D1BA4BA9
W18X35 W14X90 BEAM_TO_COLUMN FLANGE_TOP 0 0.00 -90.00 4.25 0.00 17.33 38.2888 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 57781F4A-CDE7-4FF4-BB86-2DC4061C0C86
AD312723-CCB1-4725-ADB7-8CDEA41E5FB1
W14X90 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. C733972F-E1F6-4272-A287-DB3F2FACF0E0
0DE66CD8-056E-45D6-BB65-15291ECDEAD3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.875 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 71DEE630-6CEF-42ED-A93D-8FFD7E27B01A
A0990116-875E-4BFF-A230-6FB982ADB335
W14X68 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections to a girder where there is a column flange above or below are not supported yet. 8CAFBD56-831C-4A9B-A255-7B9DA625207E
F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. F78A4D78-AD64-4B86-BE6B-E23A1FCF3C4D
354255C4-13C1-46BD-BA52-8560A1359BA6
W14X145 W18X35 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 6815E598-889F-410D-A199-6334C0E62A0F
59D4C6F3-8A47-4609-99C8-2B08E70B31ED
W14X48 W18X40 COLUMN_TO_BEAM BELOW 0 -90.00 -7.11 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.62 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 427C6FEC-A3F4-4B94-AF2F-2036950F72C5
8D0E40CF-D698-4738-BE89-65CC343BF67E
W14X43 W16X26 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections to a girder where there is a column flange above or below are not supported yet. 3E81227F-89E2-48F3-A9E8-76C9CAC23401
427C6FEC-A3F4-4B94-AF2F-2036950F72C5
W16X26 W12X14 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 20.00 22 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections to a girder where there is a column flange above or below are not supported yet. 9D406AB8-1B78-4133-BDDA-799B127C0192
3E81227F-89E2-48F3-A9E8-76C9CAC23401
W12X14 W21X44 BEAM_TO_BEAM NONE 0 0.00 -90.00 -8.75 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
9CEB8268-1533-4B64-8788-FE214DA33696
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.00 0.00 20.00 34 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. D609A66D-9839-42BC-92F6-58A3E24E5425
C276519D-931D-4557-A516-97AAA2C95482
W18X35 W21X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.00 0.00 20.00 33 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. C276519D-931D-4557-A516-97AAA2C95482
4326ED42-B1A3-42DD-AB36-B7AC28C3D5EE
W14X53 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. EB0A5650-5372-4B64-95AC-FC05B4CCD970
61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 36.00 9.20381 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
99BFD3F8-9C08-4097-818C-EDF0A9F0806F
W14X22 W14X22 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 20.00 16.5669 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
40C63F99-248E-48A3-8957-E040456F18F3
W14X43 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 21.43 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 5F3409F2-EEB2-4863-BE3D-F41423B0E21C
40C63F99-248E-48A3-8957-E040456F18F3
W14X43 W21X62 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 21.43 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 68E06054-293C-4849-BE0D-A5697055AF9F
533D23BF-124A-432B-9A4A-108CBDA05A88
W14X43 W18X119 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 3F47254E-E617-4C19-8ADF-CE741A29D5DA
29A4429C-7C11-4369-B150-41A91340B480
W14X43 W18X119 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 19.89 0 0 0 0 0.00 0.00 0.00 0 0 2029.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. D9774C64-813D-425A-921B-5050D603A4BC
932040FE-6BD9-4602-8956-8894D0165AB5
W14X43 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 -7.00 0.00 0.00 21.42 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. DBBDA364-B5E0-4A93-BBF6-7B4B1998AA26
CF3BF6CE-FA02-4047-B0A3-520C2BABD269
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 5BA9D70E-D611-46DB-BFA4-A222377D4379
62A561CB-EFCE-4140-93FE-BE548C568F08
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 20.92 0 0 0 0 0.00 0.00 0.00 0 0 2018.88 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. DBBDA364-B5E0-4A93-BBF6-7B4B1998AA26
2F5F3FE9-763F-433A-A884-EEE474444560
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.39 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 9BD7CF86-7C35-4F19-B138-5F71ED3BEC54
A2F168E3-D51E-4484-B1CF-CE93B7E3B450
HSS5X5X3/8 W21X57 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
8E991592-FBAD-489E-A6E6-610B1365B54A
HSS5X5X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 5.38 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
1884E767-2104-413D-A6D5-E2817A1CBCDA
HSS14X14X3/8 W21X93 COLUMN_TO_BEAM ABOVE 0 90.00 -90.00 0.00 0.00 21.40 0 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. E8FFA5E5-A849-4BD3-99D1-CE641157E4F4
70768AA5-CD06-4FB4-B52E-A002F75353F3
HSS6X4X3/8 W8X15 COLUMN_TO_BEAM ABOVE 0 90.00 0.00 0.00 0.00 17.20 0 0 0 0 0.00 0.00 0.00 0 0 2.96401 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
A87D25E9-1CB3-48C8-858C-480496B5824A
W14X43 W16X26 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
427C6FEC-A3F4-4B94-AF2F-2036950F72C5
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 2026.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 5F3409F2-EEB2-4863-BE3D-F41423B0E21C
C8C2BA86-6C64-46B5-9279-6521E18C5D11
W24X94 W21X62 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 16.60 14 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
499094DD-41A4-4EA3-8B57-D1D407C31029
W14X53 W24X94 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2035 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
64E291F4-9FFC-479D-883A-2B6F3CFB9E05
W21X68 W24X94 BEAM_TO_BEAM NONE 0 0.00 68.05 -3.13 0.00 21.56 39 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. C8C2BA86-6C64-46B5-9279-6521E18C5D11
93E5BAF9-BF31-489D-B072-86DFC3E13267
W14X22 W24X94 BEAM_TO_BEAM NONE 0 0.00 -90.00 -10.50 0.00 7.85 30 0 0 0 0.00 0.00 0.00 0 0 2024.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
17F2540D-9E27-45BD-8D2D-676F5D700302
W16X26 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 0.00 0.00 35.76 12.3362 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
W21X68 W16X26 BEAM_TO_BEAM NONE 0 0.00 -90.00 5.38 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
3E729E78-C4E4-4E47-BDAA-737205B93C38
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
13699A5D-FF3F-4C95-AD7C-E0A39B386076
W14X90 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. A40D0707-CB63-494F-B78F-83BF153E7098
A3B19E90-7446-4394-A3C4-F37771BD1791
W14X43 W12X16 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
A40D0707-CB63-494F-B78F-83BF153E7098
W12X16 W16X26 BEAM_TO_BEAM NONE 0 0.00 67.00 -3.75 0.00 23.98 8.36555 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
3E729E78-C4E4-4E47-BDAA-737205B93C38
W16X26 W16X26 BEAM_SPLICE NONE 0 0.00 -23.00 0.00 0.00 20.00 15 0 0 0 0.00 0.00 0.00 0 0 2284.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 0693463D-E958-47A2-8A6E-6A157F3D5270
61957FCC-C4CA-4711-BABD-96C8CE9C2A5F
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 67.00 -2.00 0.00 36.00 9.20381 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. DA24DB18-6A90-4E73-B417-15AFA2D6459C
6E4F05C5-C84B-4282-9D3A-759EF54C0C0F
W12X19 W24X94 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. EC9F51C2-9A42-4D6E-B3A7-2573CC3BEB9D
E11A9FA9-4046-4F6F-885B-B84E82038A95
W14X90 W14X22 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
EC9F51C2-9A42-4D6E-B3A7-2573CC3BEB9D
W14X22 W16X26 BEAM_TO_BEAM NONE 0 0.00 90.00 -2.00 0.00 34.21 9.68489 0 0 0 0.00 0.00 0.00 0 0 2282.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. F822B623-7C9B-4AE3-88DF-EADCA5F78CB4
349A93AA-A84A-4167-820A-E344A2DBC1F5
W16X31 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1043 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 349A93AA-A84A-4167-820A-E344A2DBC1F5
E04C1F22-7523-4C8C-9792-60EE82E00B47
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 12.55 29.00 8.50024 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. E38F5BF5-B3F9-476A-8BF8-011B1208C40A
9E20047B-C29A-49E9-B3C6-8FC2EF85B368
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
2BD545B9-B4D3-4539-A691-17D35E50301D
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
0169F8F2-6ADA-48AE-8C4C-4FE86A105E05
W21X93 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 45.00 52 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
B19FD047-D193-4F17-BD9A-E647EB2E3A7B
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 0D29E819-F503-405B-B95C-4FF0E5821A33
35B36F33-6288-429B-8D92-DA2A0B197C57
W14X43 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 38ECE23A-FEF4-4A2F-8803-F5ACA8D8F69B
0D29E819-F503-405B-B95C-4FF0E5821A33
W16X31 W16X26 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 15 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 15D779B3-01BD-4026-B23A-5946BB50BF7E
5F3409F2-EEB2-4863-BE3D-F41423B0E21C
W21X62 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 5.13 0.00 36.94 42 0 0 0 0.00 0.00 0.00 0 0 2031.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 15D779B3-01BD-4026-B23A-5946BB50BF7E
B19FD047-D193-4F17-BD9A-E647EB2E3A7B
W18X35 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 82B6DDE8-5EA9-47A7-99A7-E52B87E0CBF3
09896AA6-F981-4407-97DA-8004F60E7937
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1044 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
330773F5-4848-43C6-825B-2A3F6107354B
W14X90 W12X16 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2280.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
2E2DDB51-A50A-46E2-B9F1-6A2D23D6936B
W21X68 W12X16 BEAM_TO_BEAM NONE 0 0.00 90.00 9.13 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 2289.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 4292A297-6C52-4882-B560-7C58731A13B6
6E16102F-7F80-494D-93BE-4F0AC76ECCA0
W16X31 W12X16 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 21.17 25.4609 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 89D99BFB-B6EE-4D8B-8116-1A1BA775D16A
6E16102F-7F80-494D-93BE-4F0AC76ECCA0
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 21.17 25.4609 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 6E16102F-7F80-494D-93BE-4F0AC76ECCA0
213704B6-293E-4CA5-ADD6-B558F50C559D
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 6E16102F-7F80-494D-93BE-4F0AC76ECCA0
E04C1F22-7523-4C8C-9792-60EE82E00B47
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 -3.75 0.00 29.00 8.50024 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
74F54281-DE3A-4CA6-ABE2-5766BBA9CCAD
W21X93 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.88 0.00 45.00 44 0 0 0 0.00 0.00 0.00 0 0 2032.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 477265A2-7EB6-40CA-896A-F9FAD3AD3520
DC9CD579-EADC-4D9B-A308-0777106D1EFF
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 31 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
1F7BFCA6-0252-45BF-85FE-95269A4DED78
W21X68 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.38 0.00 45.00 40 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
DC9CD579-EADC-4D9B-A308-0777106D1EFF
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.89 30 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 1F7BFCA6-0252-45BF-85FE-95269A4DED78
8947A135-68C5-46CC-8E05-B28987D6170A
W14X43 W21X68 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
712A9B4D-EFDE-4CDC-9FF8-09579AAD85D4
W21X55 W18X35 BEAM_TO_BEAM NONE 0 0.00 90.00 3.00 0.00 45.00 25 0 0 0 0.00 0.00 0.00 0 0 2031.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. EE471D89-7596-4D4E-922C-14CE65E94CCB
3B267DA9-DCCA-414C-96DB-D25EBE0A708C
W18X35 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 19.94 23 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. E0C6A216-D539-4869-9C0F-BE322A51195F
F7041EBC-0A5F-41C2-A893-054BBEC2EA04
W18X46 W21X68 BEAM_TO_BEAM NONE 0 0.00 74.00 -3.13 0.00 22.70 43 0 0 0 0.00 0.00 0.00 0 0 1849 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 5ACCFAD4-3AF1-423D-B75C-24933259776D
E0C6A216-D539-4869-9C0F-BE322A51195F
W21X68 W21X68 BEAM_SPLICE NONE 0 0.00 -180.00 0.00 0.00 28.53 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Qnect does not yet support HSS filler beams. FAD4F938-86D1-4CF8-ABCC-59AF95146B3C
12271B2D-328A-4980-9C13-72EC0ED7C824
HSS16X8X1/2 HSS16X8X1/2 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 20.00 48.6627 0 0 0 0.00 0.00 0.00 0 0 2284.5 A500-GR.B-->A500-GR.B
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 89D99BFB-B6EE-4D8B-8116-1A1BA775D16A
9E20047B-C29A-49E9-B3C6-8FC2EF85B368
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column to beam connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
0807590A-F1FF-4219-9E8D-5634D9FB6D77
W14X90 W16X31 COLUMN_TO_BEAM BELOW_FLANGE 0 -90.00 -90.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 9E20047B-C29A-49E9-B3C6-8FC2EF85B368
D59E77B0-2045-419A-B1D3-BED72A4CFA6A
W12X19 W16X31 BEAM_TO_BEAM NONE 0 0.00 -90.00 -3.75 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 8F7D6983-98F1-42CE-A45B-6297267D17FB
80DF8878-242B-4F70-892F-77645F4FC07A
W14X90 W18X35 COLUMN_TO_BEAM BELOW 0 -90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 8F7D6983-98F1-42CE-A45B-6297267D17FB
D59E77B0-2045-419A-B1D3-BED72A4CFA6A
W12X19 W18X35 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 28.38 8.68747 0 0 0 0.00 0.00 0.00 0 0 2280.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a beam splice connection. 82B6DDE8-5EA9-47A7-99A7-E52B87E0CBF3
349A93AA-A84A-4167-820A-E344A2DBC1F5
W16X31 W16X31 BEAM_SPLICE NONE 0 0.00 0.00 0.00 0.00 9.44 57.1043 0 0 0 0.00 0.00 0.00 0 0 2284.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a beam splice connection. 349A93AA-A84A-4167-820A-E344A2DBC1F5
8F7D6983-98F1-42CE-A45B-6297267D17FB
W18X35 W16X31 BEAM_TO_BEAM NONE 0 0.00 90.00 1.88 0.00 35.67 18.6048 0 0 0 0.00 0.00 0.00 0 0 2286.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
9990395D-C5F9-4CA1-8C33-EA8CD33240AF
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1041.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
07F207CA-417E-4698-A4D6-2B2BD28C14F9
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
A1CD8BCC-EE2C-4564-B72F-E5F0082185EA
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
87FF52DD-96F0-4F6A-A339-FED94A5FAFC0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
1474C278-5BCC-4B53-A4F4-54B5E499E9AE
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1038.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
72F82F9D-AFEB-4508-BD61-4913D9487AD4
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1036.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
E86CEC60-9811-4F21-8378-1AA264B1D951
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
40BCA70D-9613-449D-A200-39CC88828505
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1039 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA2C79DF-4464-4828-8B5A-DF0586C652DD
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA9B453D-CE7A-4935-AA25-C32EB8CCB2C4
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
E86CEC60-9811-4F21-8378-1AA264B1D951
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
6BA6F088-920D-4379-B9D7-AD918F213074
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1044.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
57578118-5DED-465C-8EB1-C8D1958EA3E8
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1050.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
08611823-A0DF-4724-B96E-4FC82D2E642A
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
40BCA70D-9613-449D-A200-39CC88828505
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1039 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
4BDBC0DA-5AC0-42CD-8785-4004F4C3BC13
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
DE29FF8E-BF33-4A4A-9626-509B85110A73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
C5555BC7-464A-4206-B4E3-AEB9A0610615
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
2C703255-B570-490D-AD12-7B5768716A5A
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
68D61397-09E1-4169-88F2-FA7838BB3027
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
DE29FF8E-BF33-4A4A-9626-509B85110A73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
BE29BE2E-0573-476B-8EB5-09A2916D5146
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
5F45BE64-1227-4A36-ACAF-240C3FCCE685
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
8B94BA7F-178F-428B-A061-0CA609EC4DF0
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
C5555BC7-464A-4206-B4E3-AEB9A0610615
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
D513D20E-A0D4-4979-BEF0-9DA03CA5F2D4
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
EB8F8740-1C62-48B6-9391-56EF77C970A7
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
D513D20E-A0D4-4979-BEF0-9DA03CA5F2D4
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
8B94BA7F-178F-428B-A061-0CA609EC4DF0
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
4A514482-1250-4A1D-82BB-AB906D16E559
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
332A4BDE-4B5B-4DFD-BB8E-A7D5C614EC76
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
C3B67647-C79C-47A0-957D-31D9A00FFE08
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
36938698-4BA9-41BE-917B-A36EB9A0FC7B
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1036.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
EB8F8740-1C62-48B6-9391-56EF77C970A7
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1042.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C3B67647-C79C-47A0-957D-31D9A00FFE08
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
E402D4C8-8B0E-412D-A2DF-E8234A150806
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
7B5D0835-3264-438C-A363-E584CC040CBC
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
8E939106-3544-4847-A451-02B9FE563093
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1038.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
5F45BE64-1227-4A36-ACAF-240C3FCCE685
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
4662964D-09EA-474E-82DF-190E3404786F
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
4BDBC0DA-5AC0-42CD-8785-4004F4C3BC13
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
4A514482-1250-4A1D-82BB-AB906D16E559
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
7B5D0835-3264-438C-A363-E584CC040CBC
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1041.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
BD1608D5-8C87-4301-B0C2-A6C3BDE7EE2B
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1032.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
79E706EA-CF58-4772-9C52-24C59E7AA11F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
FDA425D1-9A5C-4304-BD4B-B83B47B6A6E1
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
4D69B209-DC9D-4C2E-90A3-363A0EAAB9A8
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
B83E4BFD-35BE-4E6D-A243-7DE904AACCD0
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
2FC6C261-A9BB-460C-8276-697979348CBC
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
618B7D73-0831-411D-83B4-6D185E515F74
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
ECC79D6E-8DF8-48F9-960B-DE3BD0B9B10D
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 715 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
DCC42B0B-8198-48F8-9008-1140575A294A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
5568689A-8E7E-4EFB-B746-91800AF5BBE3
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 714.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
4D69B209-DC9D-4C2E-90A3-363A0EAAB9A8
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
90193749-4D48-4485-94A4-712852C1075A
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
E409BE8E-7F0A-4F4E-9E9E-D5C46BA399A3
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
79E706EA-CF58-4772-9C52-24C59E7AA11F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
48F21262-19B0-4C58-B229-37695B5C54A8
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
7C017594-77A8-4254-A474-5466C182C66B
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
B5CEAB43-AD5C-462C-A73B-1CD1C0CF3DB7
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
8CCD67C9-8EB9-439A-BC21-37ACA0E5BC94
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
6C2FBE47-AC97-464B-84C9-B7A0DCC5D04D
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 718.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
E4FB8F81-2AEC-4CCE-991C-9E0A5814A3E4
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
CDBC348F-F280-483D-AA9A-21F9BF34D9D7
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
90193749-4D48-4485-94A4-712852C1075A
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
DCC42B0B-8198-48F8-9008-1140575A294A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
814463BF-E07A-4868-BA19-1AF3BBC0F82A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
F1F2E840-F729-4D5E-88C4-2F02C285D9A9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
E409BE8E-7F0A-4F4E-9E9E-D5C46BA399A3
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
F20C520C-6FAB-4611-86E4-E8C30BB2B733
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
E4FB8F81-2AEC-4CCE-991C-9E0A5814A3E4
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
F1F2E840-F729-4D5E-88C4-2F02C285D9A9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
814463BF-E07A-4868-BA19-1AF3BBC0F82A
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
2FC6C261-A9BB-460C-8276-697979348CBC
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 717.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
52F03D7C-F789-4945-A234-8CEE041E5A17
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
ECC79D6E-8DF8-48F9-960B-DE3BD0B9B10D
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 715 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A4BCA449-3F74-4868-92C4-37314EE32E81
C18CECA7-786E-438A-90F1-3E9D531A96FE
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
10182BFB-3F0E-402E-B372-A4CB2E5E1742
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 27 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
F4EE37B9-E741-4D36-B39B-06EF520F33D4
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 712.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
52F03D7C-F789-4945-A234-8CEE041E5A17
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
8A0DC28B-E36F-4C92-9D8F-05A2573685DE
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 708.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
513CA458-BCA5-4485-887A-7CCBE0A15528
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 720.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
96E8B22E-A55B-4E49-B1AE-93DBB8E7B139
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 726.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
6D387DF4-1A84-49B7-B50B-FD77E469E6CF
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
F54B8854-C8DD-4C13-8AD5-1335CE677D12
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 877 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
0AA99F9D-AF78-4DD6-8A64-B3B5E44A4B77
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 879.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
44E2EFCE-86D0-4CD9-BAB7-0B0E4D5DA0F4
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 714.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
9D890586-34C2-47C3-8614-76DCB516DB1A
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 717.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
E4680621-D95B-4976-BCAE-FC08E98DE74E
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 712.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
02354002-467C-493B-8F08-6C88474D3AD4
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
EBB3572C-49F2-4487-9934-020C03DB822F
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
691C75C1-2582-401A-AEEE-F15C09A6C35E
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
689ADEB9-9825-4A62-88EE-1A1315909242
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E4FE6769-C272-4974-8777-AA845DD7091E
1F94773B-2930-461F-A854-48D77DA01A32
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
3ED42457-E046-4E6B-AF46-8004D040E5DA
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
1F94773B-2930-461F-A854-48D77DA01A32
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
4DCE8FB6-B3C1-4586-8573-8E3AE1C19FF5
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
6772C9AD-A31C-4F13-BDED-9E3B86D17F45
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
4DCE8FB6-B3C1-4586-8573-8E3AE1C19FF5
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
09BEC59D-D492-43E8-85E0-394F7BEF0944
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
6772C9AD-A31C-4F13-BDED-9E3B86D17F45
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 880.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
42013A6D-FA13-4A89-BADC-7FB88D1CC700
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
2E8C7F2A-45BB-41E9-A2EC-A1D470577F0F
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
689ADEB9-9825-4A62-88EE-1A1315909242
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
0822EADF-84F2-4E9F-9DF6-F4CE3511C282
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
6903FA2E-8371-4DFB-9E55-F39121BF277D
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
8D0EE022-267E-493E-AD7B-F3D62C548A88
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
4F863091-9932-455D-B755-9D8FB784721A
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 876.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
6903FA2E-8371-4DFB-9E55-F39121BF277D
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
5034D831-8F41-417E-A845-25F84C493354
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
1C1FC92B-3571-4867-91E1-3AE35F72C25C
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
F54B8854-C8DD-4C13-8AD5-1335CE677D12
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 877 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DB888ED2-2EFB-4594-B51A-BE66A8A25278
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
206F21FD-019F-4E90-B100-F1A4020AF3B3
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 874.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
1C1FC92B-3571-4867-91E1-3AE35F72C25C
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
9ECF74B0-3B1B-4A46-A31F-074BD6CA5067
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3EDF3563-93EB-42E2-94D2-048DCEFD098A
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 882.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
ACEC7EE8-E7E7-4F4D-8481-ED07320975EE
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 888.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
644134AB-98B2-490E-A698-D3D69D9A15E0
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 874.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
08CF93AC-05E4-4744-B7BB-41B07352052B
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 876.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
3ED42457-E046-4E6B-AF46-8004D040E5DA
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
38556A05-88D1-49DC-93DC-58ECCDA27F73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
DB58F1F5-9B73-42A2-9855-8519B825AEAC
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
42013A6D-FA13-4A89-BADC-7FB88D1CC700
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
691C75C1-2582-401A-AEEE-F15C09A6C35E
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
38556A05-88D1-49DC-93DC-58ECCDA27F73
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
8D0EE022-267E-493E-AD7B-F3D62C548A88
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 879.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
6AE98562-7689-4F55-927F-1769383AD9AD
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 870.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
5C055762-0D11-4C2D-B0B4-3CF176B40298
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1527.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 313E3F6D-87A2-4330-8BD4-7291B3E9511D
F476C5A2-1C06-4C32-9622-AA025E32CB44
W18X35 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1524.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
02E3C9C6-6632-4F27-B884-583D1882EF33
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
A7C16C77-3A1D-47FC-B2F1-148BA4C6AAF3
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1525 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
600E9556-6A64-4F03-B737-E766786707F8
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
DD9BDCFA-1240-4FFB-980D-63D1972D8F95
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
5AEC3194-1010-410D-AB2B-5F5370F3888B
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
60A11EE5-9F01-40A5-A6E6-6F6C8BC49103
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
99CF7CD4-000F-42F4-92B1-FC7C1F9DD098
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2C2A0152-D6D9-4A67-A13A-A5BA5BD894F3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2C3EADC4-CF75-4C6D-894E-41DE9BE3D333
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
5BBBDEF4-5293-4109-A7FD-48C1B7FFE778
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
8FBB6A7C-0409-4BC4-B12A-F1A176D2ADB9
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1528.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
1CD20200-26AF-4DD6-9C56-B4ED2100A5B2
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
909A473B-9768-4743-9EB3-DD31AEC2DBF6
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
0B8ED8BF-7302-490B-828A-4FD33A9AA395
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1689.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
3B5CBB2A-756A-4DC4-BFD0-01A234A06FBB
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
D493CF11-869D-4C64-8349-3A093CDF3527
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1687 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C284BE98-8C8B-4F63-A459-B4C32103553D
BBCA9207-8685-48F3-BD48-5586F1327BAE
W14X48 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
B61368C3-F1F0-4877-8A2F-9C1560903460
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
D4CF178C-8391-4B21-849E-53C3C2811D0F
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
A7A435DA-E1FA-430C-A7E0-DC46A2EDD5A6
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
263343D3-EECD-472D-8B1E-BA0725ABB96A
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
E95CC985-766A-40B5-843A-91C246B9ECEA
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1692.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
68374965-673C-4F2A-B6E8-1E2A35BB5D67
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1698.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
7478B226-28CE-49A7-9ABB-1AD84BE3752C
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1684.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
9C094811-32D4-4AC9-8610-0B0ECF2DA51C
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
2ED7D7BE-C726-439C-B383-6161815B50E9
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
B866C8BC-C813-43DF-8D28-DE1206793453
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
A79EAA08-06A7-49D1-BEB0-F4A692CFCE76
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
3A974128-BAE4-4620-A864-5A5DA17CBDA7
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
A79EAA08-06A7-49D1-BEB0-F4A692CFCE76
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
E37DDECD-720B-417F-995A-9C11964818DF
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
4C830EA6-7678-490A-8B36-438FC2E09D1C
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
B866C8BC-C813-43DF-8D28-DE1206793453
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
EFD9D322-8321-42E0-B05C-213EA2EA5BBB
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
E0FA1338-D96B-44F1-A658-7D769EDC882F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
F1DEBF2C-3B33-4DDC-9D7F-86A562F621A6
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
E0FA1338-D96B-44F1-A658-7D769EDC882F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
DAD17DA8-E0C4-4067-AF7A-93553C415567
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1686.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
4C830EA6-7678-490A-8B36-438FC2E09D1C
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
B26A91E2-7FBF-47CD-AC68-46CE305F0411
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
29D8A9E7-ADE8-4366-87B3-9AD4A85050A6
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1684.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
D276D777-F9CF-4B9C-96C1-78318DE09FED
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
B9EA48A0-46B8-4028-AC7F-117DADA7DEF0
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
6D3097C1-575C-4A8F-80A0-E9F3AF2AA0A0
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
EFD9D322-8321-42E0-B05C-213EA2EA5BBB
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
3BE858F1-3ED8-41E9-9E63-53B092C374FF
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1680.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
D276D777-F9CF-4B9C-96C1-78318DE09FED
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6D3097C1-575C-4A8F-80A0-E9F3AF2AA0A0
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
3A974128-BAE4-4620-A864-5A5DA17CBDA7
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6533527D-87BB-4684-B4B4-7F283841B16F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
E6C8B764-8E5F-4002-ABFA-5173CF9A08ED
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1690.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
6533527D-87BB-4684-B4B4-7F283841B16F
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1689.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
82BC3F73-3226-43A7-BF39-2F8A5A8DF305
W16X31 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1198.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 134936D7-07A4-41B1-A8DE-EF7052CB2656
D0C9055C-C95D-4CF0-A952-EC0F4C860212
W18X35 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1200.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
5E4049D3-8400-49DF-97B9-D447A71A47FE
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
F24D6827-EF28-42CE-8A89-F5B5AA91949D
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
9B1E10B9-490A-455C-8B2D-9D7975A2E924
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
B78071DB-FBFB-4858-A7C0-84C0D2439FF0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
C384AEFB-93B1-4BAF-99FF-9FE8969585A1
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 113ADEAB-1E0C-4E18-83F3-F64DD28473FF
CBFE8BCC-04AA-4588-A971-BD5A0EA51521
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
5E4049D3-8400-49DF-97B9-D447A71A47FE
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
87FF52DD-96F0-4F6A-A339-FED94A5FAFC0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 0EDEBE74-842C-4C52-804E-B50CC340296B
CBFE8BCC-04AA-4588-A971-BD5A0EA51521
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
A1CD8BCC-EE2C-4564-B72F-E5F0082185EA
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
65551263-D3C7-4A9C-9051-02E863BBE33E
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
AD7F6766-68F3-4FEE-A40A-ACB2241635FF
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
0CD67DF9-7524-4913-9707-A993AAB38E14
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 31137C4F-3F63-438D-AFDB-7950376A8126
D8696BAE-DDE7-4C45-B160-DF771D795EEC
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
D27ED056-4C4D-43FB-8EEA-DC310B5B5DD6
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
55E8770B-B960-4C16-B268-11221343DAD8
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
AD7F6766-68F3-4FEE-A40A-ACB2241635FF
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 4A851DC9-81A8-430C-9E92-B0040852819A
645DE082-39CA-4731-A6D4-66FE413595C7
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
07F207CA-417E-4698-A4D6-2B2BD28C14F9
W21X68 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
F24D6827-EF28-42CE-8A89-F5B5AA91949D
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
D27ED056-4C4D-43FB-8EEA-DC310B5B5DD6
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
96032FED-706D-495B-AF80-D6469A64D0E5
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C0139783-4A96-4DFD-BC58-47B07868F60A
W16X26 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
C384AEFB-93B1-4BAF-99FF-9FE8969585A1
W21X122 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1204.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
B78071DB-FBFB-4858-A7C0-84C0D2439FF0
W21X68 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1203.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
19922770-D3D0-4B84-A77E-CD6E4ADBDEBC
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C18CECA7-786E-438A-90F1-3E9D531A96FE
C284BE98-8C8B-4F63-A459-B4C32103553D
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3920436F-0D69-42D9-92ED-5EB2A1854AF2
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
B11ABEDF-B74E-47B4-A3D2-00EB87ED4F40
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1198.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
0ED27B40-69EC-49F1-821F-463086065E57
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
9B6CCE28-C3CE-4306-BE2C-583C7A374A28
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
30D80433-5F2B-43A3-BB33-539C9C1B3012
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1206.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1212.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
0ED27B40-69EC-49F1-821F-463086065E57
W12X14 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 1194.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 695DEE27-D1D4-4359-BA69-F51FC052A6A5
D15610A2-DBEA-43C2-BCC7-DF88E58A1448
W18X60 W14X90 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1201 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
4DE834F5-0DB8-40AD-992C-DA6638990EFC
W18X40 W14X99 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1200.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 94ECA3BE-EB62-4102-ACA2-674291E7218F
D15610A2-DBEA-43C2-BCC7-DF88E58A1448
W18X60 W14X99 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1201 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. BE86D4E7-2CA5-4CB6-9431-C640068DA113
0E759104-908A-4B1E-BF17-38C4378267ED
W21X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1203.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 313E3F6D-87A2-4330-8BD4-7291B3E9511D
087B0D32-CAA8-41A0-844E-8DECB3B64D2D
W18X35 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 1362.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9FF912D-F57B-4621-AD56-820FFDFF41EB
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
265B3CBE-072B-4CE2-9EE1-FC28AAE074F9
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
D8A4934B-F55F-4590-B143-880EEE11A922
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
06961564-5173-4DBA-B492-336B919CD8AC
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
5EC7EC86-9DDE-43A1-91E4-AE09322B7360
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1368.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C7213124-48AA-40CB-B8DD-61160DF07882
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1374.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
1BE10706-69DF-46B6-A76A-BF37A9E82588
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
2C0FFF3E-B39F-4D78-B522-CBFB10B18124
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
26A03CC8-A1C5-42EA-ACDB-41C953479896
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
1CD20200-26AF-4DD6-9C56-B4ED2100A5B2
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
1BE10706-69DF-46B6-A76A-BF37A9E82588
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
13A4B26E-830E-4BE7-B968-5BB5D175599A
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
600E9556-6A64-4F03-B737-E766786707F8
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
E78330FC-19B4-4101-92FE-E35425AC7D3D
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1522.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
59034CCD-412A-45C4-8B12-024E027CD2E8
W21X55 W14X120 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 1365.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
65AAB779-19C1-4FB9-BF7C-5FA9B07C72B7
W16X31 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 1360.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
2B42C63E-1F18-4A7E-BB3C-9D526B812C83
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
2C0FFF3E-B39F-4D78-B522-CBFB10B18124
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
60A11EE5-9F01-40A5-A6E6-6F6C8BC49103
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
F6C84A6B-A4B5-4C74-8C90-B67F696BC4F1
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
2B42C63E-1F18-4A7E-BB3C-9D526B812C83
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
F75AA877-EFD5-4760-BF3B-CDB63BF36D84
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
13A4B26E-830E-4BE7-B968-5BB5D175599A
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
F75AA877-EFD5-4760-BF3B-CDB63BF36D84
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
565274B4-2FF2-4D87-B632-1BEC81AE60D8
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1524.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
2C2A0152-D6D9-4A67-A13A-A5BA5BD894F3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1527.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9B41AB5-9928-4556-B238-0DB97FCBEDA7
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
DB2DCC2D-0928-4A7B-9657-F26B2C0F0C17
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1522.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
49CA5CFB-F823-4DB3-9E34-9C81B2DF2602
W12X14 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
DAB357CC-1145-4228-96A8-B56406947794
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 1518.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1530.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
9ED7B62F-8CF2-4A54-821D-1C08FC0622BB
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1536.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
125CEAD5-2A48-4C7A-9EEC-3067C05E2FAD
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
5950A269-3C8D-47A4-B6A4-B776976D2A70
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
27C98207-E2E3-420C-808F-1E2C41D23838
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
17DC808C-4200-48A8-BD95-E6D63D750CEE
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
684F750A-1713-4A5B-9C13-67491BF20952
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
F8B7F6EA-09C5-4B44-A782-95698E60E2FE
W16X26 W14X53 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
049BBF43-0F2F-45D9-AA4C-62D4530A7A96
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
57570467-7F5C-42C0-93AA-58DB1A1E3350
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E02CA80D-FC59-4556-B8EE-65046563BC1A
F4E64A91-7316-4339-9A7D-A40E2961872D
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. F3004609-63D0-420E-B92C-2AEA3D319B66
6831B7C4-D1AB-4A2F-A7F3-045968A9502C
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
33758C8D-DEE0-42C7-9857-E163188E4C4F
W16X26 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 1360.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
4AD7F4C9-4E9A-4421-B6E6-F715CD4D8540
W21X122 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 1366.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
17DC808C-4200-48A8-BD95-E6D63D750CEE
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
307F3923-F3F1-4797-8B0F-9947D954E81D
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
57570467-7F5C-42C0-93AA-58DB1A1E3350
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
2B54F546-F091-4F35-87A6-0C3CD0529A3B
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 96B87704-8949-45CC-B092-EB20FB25B31F
4FACBCAB-A75E-4AE3-B242-588EF02286D3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
049BBF43-0F2F-45D9-AA4C-62D4530A7A96
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
5950A269-3C8D-47A4-B6A4-B776976D2A70
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
FD5DED3E-6F8C-421A-98E3-1C285E33FECC
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 234B93AF-4538-475D-9E47-9CC39023D2EB
CEA25699-3307-4688-9462-42725037FE0C
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
FD5DED3E-6F8C-421A-98E3-1C285E33FECC
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
2DC7B671-44FA-4DA2-B22F-ADF1B217F996
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
4FACBCAB-A75E-4AE3-B242-588EF02286D3
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A37ED7B7-1F1E-4221-854A-22E084052C34
E9680558-D287-4B05-93C0-A88F87DA6E51
W12X14 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 1356.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
125CEAD5-2A48-4C7A-9EEC-3067C05E2FAD
W21X68 W14X120 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
F4E64A91-7316-4339-9A7D-A40E2961872D
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6831B7C4-D1AB-4A2F-A7F3-045968A9502C
W21X68 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 1365.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
612C667E-1F48-4071-9D75-4F984044C791
W18X40 W14X82 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1362.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
24790D35-0C18-466A-AD1E-08FE9E5C5E73
W18X60 W14X82 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1363 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
A0BF4D51-F4D7-4361-A522-B3827E544B24
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 24 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
705D515C-E499-4482-A35F-A4BB13F49404
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
B5D3DC47-51B0-42DC-8E9D-AE215948B0F9
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.87 83.01 0.00 0.00 9.30 25 0 0 0 0.00 0.00 0.00 0 0 6.48013 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
7ED2D326-C623-4555-9189-37E5CB200D8D
W12X14 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 6.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
FDB433B6-6EF3-43B9-964E-D84A8F0AE59A
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 15 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
D6E8D097-7CCD-4AD9-8E4E-BF98E4C3ED73
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.994 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
99B9CC92-97EC-4D10-8B06-EC68F5EEC225
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
FDB433B6-6EF3-43B9-964E-D84A8F0AE59A
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 11 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
0126C1D4-74D6-4685-80D8-6DCD6791E415
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
553EACB0-7D39-4917-A543-85C8B8FEC36A
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
99B9CC92-97EC-4D10-8B06-EC68F5EEC225
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
C83F4780-5F40-4B15-8CD5-5A82452C20D9
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.05 30 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
B5DD25C8-2788-4505-A2A6-DD77854C02D6
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 14 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
0890C31C-0E92-47C3-8678-FCCE88B205BF
W18X143 W14X61 BEAM_TO_COLUMN FLANGE_BOTTOM 0 0.00 90.00 19.50 0.00 32.48 72 0 0 0 0.00 0.00 0.00 0 0 2030.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
DA3A0C2D-E764-4BC9-8723-5B11909E3C86
W18X35 W14X61 BEAM_TO_COLUMN FLANGE_BOTTOM 0 0.00 -90.00 17.75 0.00 32.52 18 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
D6E76792-486E-4F11-A233-E4513053F9FA
W12X14 W14X61 BEAM_TO_COLUMN WEB_BOTTOM 0 0.00 90.00 11.88 0.00 9.95 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8D380BA7-470A-46EB-AC04-0B346404ABEE
3FB8FB5A-E6E2-4140-824C-055B07B10A46
W14X61 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 2010.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
00E6C459-ED81-4936-BC31-A88AA57F456D
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 229 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 9DBDF860-DBFF-4712-AC7A-3A30D8948579
CDA74AA3-DF88-4810-8889-35ACF1918E5F
W18X35 W14X176 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 228.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
CB690996-6939-487D-B49E-D45538E58682
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
E3DA22D7-6927-4271-B064-7B4BF029577E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
553EACB0-7D39-4917-A543-85C8B8FEC36A
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
EB4B7D4A-C24F-4499-872A-D652A479E978
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 105.651 0 0 0 0.00 0.00 0.00 0 0 16.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
CB690996-6939-487D-B49E-D45538E58682
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
814803E5-FB62-4ADC-97E3-87E82C9C045E
W12X14 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 849D18B6-F17A-437D-81B4-ECB9779C307A
C53670DB-A3AD-4FC1-92B9-C7FC2059B24D
W18X60 W14X145 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 229 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E314A306-7243-4D8E-B2B6-AAE799C6E321
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E79D86EE-97AC-4B9A-B282-A608B7763E08
W16X26 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
814803E5-FB62-4ADC-97E3-87E82C9C045E
W12X14 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E9B055B5-F871-4E8C-9996-F7E04F034332
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
W24X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 234.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D5B94786-A91C-4967-982E-220EF3465CED
W30X108 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 240.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
A4BCA449-3F74-4868-92C4-37314EE32E81
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
339B6FFC-483E-4D6C-9039-D2E895C8DC9F
W21X44 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.93 38 0 0 0 0.00 0.00 0.00 0 0 2031.38 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
64E291F4-9FFC-479D-883A-2B6F3CFB9E05
W21X68 W14X61 BEAM_TO_COLUMN WEB 0 0.00 68.05 0.00 0.52 21.56 38 0 0 0 0.00 0.00 0.00 0 0 2031.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
DB8BBBDA-7B8C-4FA3-AC76-6DF0013F4352
W21X50 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
1F15AD9A-5A71-4CE6-9828-DA0D947A6915
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 23 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
705D515C-E499-4482-A35F-A4BB13F49404
W18X40 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 24 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. 254E104A-3A1C-4C1A-9853-5744B3552047
BFF1BB7B-2C4A-4AF2-8E1B-76A4682D9204
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.68 83.02 0.00 0.00 11.73 25 0 0 0 0.00 0.00 0.00 0 0 6.5242 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
DD2ADE8C-7BCB-4062-B7E8-763D1F1AD88E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
20A14B6C-AFC7-478D-A7D0-E12867770854
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
B402A432-EB6B-4DA1-98B3-C02A78CA3B0A
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 0DC49D64-D312-4295-980E-8186405BADF1
3252DA2D-96CB-4031-9D99-543A1C2D59F3
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
670CCB57-4B65-444C-80B2-28AA76336512
W12X14 W14X145 BEAM_TO_COLUMN FLANGE 0 0.65 83.01 0.00 0.00 14.19 12 0 0 0 0.00 0.00 0.00 0 0 6.52873 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
0CD686BD-D8D9-4987-A7F0-569583C5C2C8
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 24 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
1F15AD9A-5A71-4CE6-9828-DA0D947A6915
W18X40 W14X145 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 25 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to the beam being sloped and skewed. 1AA81CB9-0E1C-48F4-9936-67143001393A
4922D3E0-63E3-45DD-BDCD-28F3357D185D
W21X50 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 44.90 33 0 0 0 0.00 0.00 0.00 0 0 15.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
3425B209-B0D1-430C-862F-53A0F747EF54
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.90 -90.00 0.00 0.00 21.17 22 0 0 0 0.00 0.00 0.00 0 0 12.6105 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
B5DD25C8-2788-4505-A2A6-DD77854C02D6
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
0126C1D4-74D6-4685-80D8-6DCD6791E415
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
94BBF2A4-A4D1-49A6-9406-4254F86A012D
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
E3DA22D7-6927-4271-B064-7B4BF029577E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
D6E8D097-7CCD-4AD9-8E4E-BF98E4C3ED73
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.994 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
AE7BB2C3-935A-48D7-96D5-1121EF0D4258
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
9AFB54B4-E145-40EC-8DB7-E9729A40D2D0
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
E54E4D50-A406-493F-898E-6B059B28A71C
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
945B9712-14B0-4C6D-8D0E-240621A4E6CF
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A254393B-C4CA-46A8-BE5A-5DA128358058
313080E6-FCA6-4F7F-85B0-F1FC944996FC
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
EB4B7D4A-C24F-4499-872A-D652A479E978
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 105.651 0 0 0 0.00 0.00 0.00 0 0 16.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
94BBF2A4-A4D1-49A6-9406-4254F86A012D
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 15.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
DA96F8D9-146B-4D17-ACA2-DA625F30A09A
W18X40 W14X159 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 12.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
0EFE6B55-BA7F-4306-BEF4-9FA30B4B423F
W18X60 W14X159 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
DC6DB2A9-3885-4421-B0E3-E96E06A3292C
W16X26 W14X283 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
AE7BB2C3-935A-48D7-96D5-1121EF0D4258
W21X122 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 232.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
3252DA2D-96CB-4031-9D99-543A1C2D59F3
W21X68 W14X283 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
D0336686-216C-4690-AC5E-0E7D950E66F2
W12X14 W14X283 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
DD2ADE8C-7BCB-4062-B7E8-763D1F1AD88E
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
313080E6-FCA6-4F7F-85B0-F1FC944996FC
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
9AFB54B4-E145-40EC-8DB7-E9729A40D2D0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
E54E4D50-A406-493F-898E-6B059B28A71C
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
20A14B6C-AFC7-478D-A7D0-E12867770854
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
E8AA279A-91C1-44E3-A531-6BEF522F95C0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
28F3829B-C801-4A56-9435-B54D0B4364F4
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
A09FDA1D-56F8-4B6C-8D85-C8ED27DCC97A
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
7866FAFF-8546-4D6D-B0E2-054488B5447E
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 226.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
945B9712-14B0-4C6D-8D0E-240621A4E6CF
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
59DACF10-6852-43F9-85B6-6E8CF5997774
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
A53F4FED-4FC1-458C-9DC5-13C1782BF3FB
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
E8AA279A-91C1-44E3-A531-6BEF522F95C0
W21X68 W14X257 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
920C707D-B075-49B9-9701-A738BFF18234
W18X40 W14X257 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 228.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
A53F4FED-4FC1-458C-9DC5-13C1782BF3FB
W21X68 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 231.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. ED470781-19F2-4212-B5DF-A6C96B2CBECD
48C381A4-0673-44D1-8533-3BD18B793EC0
W12X14 W14X257 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 222.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
215418CF-5155-4DE7-BF8D-FEA7D331BD5B
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 550.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
CD691887-0366-4900-BB82-ED1344C3C500
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 393.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
E1A24D1C-C617-446C-814B-5DAA9723899B
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
6D7A7A62-7283-4A9F-AA7F-272B51C22F76
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 553 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
51722E2E-DE77-4900-A816-96B0B6630476
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
6D7A7A62-7283-4A9F-AA7F-272B51C22F76
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 553 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
B97C2FC4-AEBC-4586-BFD2-2838ABD4CE22
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
E9A564FA-1924-4FF2-911F-C01F6D2D7BFA
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
51722E2E-DE77-4900-A816-96B0B6630476
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
493FF51E-9946-49B3-AE0A-6B3E3359B27C
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
C467921C-493F-45AD-9E62-A315333FD341
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 558.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
2DFE2DB3-B007-4F74-9E03-FAD3F1C597E8
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 564.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
DB60F5ED-7F55-4689-9444-86D24B90E382
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 552.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
3BBA3389-445C-43F3-AF4A-1585B2DFB030
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
142FEC85-4328-46DC-9110-E0FC51D7A18C
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
4508A29D-E08E-4FE2-BDFE-001B670608E9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
F5B0BE9B-BA87-4BC0-AD40-3D5DF02994A8
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
C1BF1EE8-BA5D-4DFA-A1E8-AADDF0163B02
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
7320BF9A-8B9F-4B33-827E-49AFC1FFF44E
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
8809F9F8-675B-48A4-B63B-4061C523CCAE
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
483414A3-6E05-4E69-9401-F9A00FE1A469
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
A4B93EE8-1839-4C1C-A119-DD5B38B9010B
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
4508A29D-E08E-4FE2-BDFE-001B670608E9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
8809F9F8-675B-48A4-B63B-4061C523CCAE
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
CD6957AC-0223-4962-94D8-DFB3E815DFB0
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
A1EA0FCD-E4CD-4D62-B31F-82D016C7D8FB
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
F5B0BE9B-BA87-4BC0-AD40-3D5DF02994A8
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
703BBCFC-E599-4FC0-807B-0FF980FC2EAC
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
6D45C4D1-4942-43F4-BBB8-19F1F5C7A6B7
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
7DB6F78D-008F-4DC2-BC7A-72F695E45D03
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 550.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
C59419E9-8972-4BF5-9C20-03A9CDDC97B5
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
A4B93EE8-1839-4C1C-A119-DD5B38B9010B
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
1076266C-185D-4A02-8800-814B68103DA1
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
C59419E9-8972-4BF5-9C20-03A9CDDC97B5
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 556.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
F3AB266F-C75E-4888-B28D-4216A7ED2309
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
7320BF9A-8B9F-4B33-827E-49AFC1FFF44E
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
C1BF1EE8-BA5D-4DFA-A1E8-AADDF0163B02
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
F3AB266F-C75E-4888-B28D-4216A7ED2309
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
CD6957AC-0223-4962-94D8-DFB3E815DFB0
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
EF2D951C-8656-44CA-9BB3-4967F028741A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 552.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
6D45C4D1-4942-43F4-BBB8-19F1F5C7A6B7
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 555.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
73E43823-B9B5-46C0-85C0-8DF1C8F77851
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 546.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. D2EF0942-F263-4253-BC4B-B59575638260
97E1E225-1274-49B4-96F0-9C15B10FE79A
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 12.29 53.9937 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. D2EF0942-F263-4253-BC4B-B59575638260
9A311228-BADA-4939-BE09-4284DC537648
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
4AE76E9F-B103-46B2-97C1-87B7FB7EE2B8
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
4026F438-CC44-469E-AC07-AFC814A0CC6A
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
16925C51-1F48-41C3-9177-57A81D862BB3
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
B96F4850-C700-4F58-8D68-715FFB63113B
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.38 56.2751 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
1D0C6816-70F2-4F04-821A-B92F7C1533F8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
2BFAFBEA-D909-48E2-B6C0-B42141CA56D8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
34DCD9A0-605E-45AD-A374-12FB713BAE3D
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
AA7E27DF-A8A1-445A-8B8A-CC454324696A
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
9943EA03-024C-4CF4-A4F3-7F3562E0AD59
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
29A1B8BA-6027-4464-B136-C7B5AA2E4B6D
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 8947A135-68C5-46CC-8E05-B28987D6170A
2BFAFBEA-D909-48E2-B6C0-B42141CA56D8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. 8947A135-68C5-46CC-8E05-B28987D6170A
AC5F84E0-62FB-4AE2-A46C-C7BA4A157CF6
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. DBCF94F7-3931-4CEE-AAD5-853E22487073
F16F62A7-7E7D-4653-B4DF-E4926C59E7C1
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 28 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 0807590A-F1FF-4219-9E8D-5634D9FB6D77
5B977253-D4F8-49D0-8B37-9DF50097A4EB
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
6C7A6345-CDE3-4275-986F-8707EC66583B
W16X31 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 56.7286 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
FC2D3CD0-BBDB-404A-AEF5-6D99D0342A00
W16X31 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 46.8628 0 0 0 0.00 0.00 0.00 0 0 2026.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 90D3759D-A468-44EC-8E1E-D8C401E416DB
18F3B61B-8D5A-4B6C-9C3F-FC3CDE294C18
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 17 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 330773F5-4848-43C6-825B-2A3F6107354B
4DB142DD-A279-41FA-8D8F-CF728D3ECCA5
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 25 0 0 0 0.00 0.00 0.00 0 0 2022.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 213704B6-293E-4CA5-ADD6-B558F50C559D
271D2626-0320-4503-970C-4CDC8E455B81
W12X16 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 21 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
25257CB7-B2D7-454C-B13E-0901FEDC12CB
W18X60 W14X61 BEAM_TO_COLUMN WEB 0 0.00 68.05 0.00 0.52 21.56 27 0 0 0 0.00 0.00 0.00 0 0 1849.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. E1B4F607-514B-4910-AB2C-8FF24EE0A2CF
6D3D51F9-DBF5-4F75-AD74-88267A6C1C0D
W18X40 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. E7058D14-9D97-4EDD-A51C-89B97DE7273B
00ABD163-DF19-4235-84A3-3A45A12E2153
W12X16 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 2022.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. E7058D14-9D97-4EDD-A51C-89B97DE7273B
704847F5-1E77-4AC8-81D5-37A5BB35BFE0
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -84.95 0.00 0.00 36.00 42 0 0 0 0.00 0.00 0.00 0 0 2028.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
CDDD3D90-928C-4BB1-8EA9-5393C4086352
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.09 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
FCE74F5C-7E95-4F46-9C0E-0F0DD1E95B00
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
55785F59-9B60-49F3-B58C-30AA03B68B3D
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.66 15 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. D2EF0942-F263-4253-BC4B-B59575638260
BDD81669-5227-4716-9701-F44DD84165A4
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 9891A6D6-73F2-4A01-84C5-5A080393E4D6
E9AF61A6-5511-42A1-897F-9E557B228C89
W21X55 W14X211 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 555.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
22CDA226-78CF-4C8F-8DB6-D4D678B63B83
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 29 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
34F8A10A-2A9F-47CF-B528-26A7ECB83C95
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 12.38 16 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
CCC0A360-B70F-43D5-BA9A-8E41DBF25414
W18X40 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 36.90 23 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. 7AF1A487-25FD-474C-ACFA-2872A3AE369A
F52BD167-B6EE-414B-BE1C-48DE68B38C89
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
678C216D-A746-442C-A380-918D283211AB
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
4026F438-CC44-469E-AC07-AFC814A0CC6A
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
F8BFFA22-B903-4889-B2FF-9C6639EDAB40
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 213704B6-293E-4CA5-ADD6-B558F50C559D
564E280D-FEBE-4696-A186-76C3576D57AE
W18X40 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
CA56BEEF-CF7E-434A-A0F0-B2490071D5AA
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.71 25 0 0 0 0.00 0.00 0.00 0 0 1842.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
16925C51-1F48-41C3-9177-57A81D862BB3
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
BDD81669-5227-4716-9701-F44DD84165A4
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 90D3759D-A468-44EC-8E1E-D8C401E416DB
756CC3BE-1916-4639-9DFD-4E355FC13213
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. 35B36F33-6288-429B-8D92-DA2A0B197C57
E5AF0CBE-0F33-41FC-8FF4-51D22C9E505C
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 19 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. 35B36F33-6288-429B-8D92-DA2A0B197C57
96C1C0AD-8B52-4BAC-8C4E-CD714FBFCC6F
W16X26 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 14 0 0 0 0.00 0.00 0.00 0 0 1846.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
A9FD66AF-1B8B-40FB-B3B4-3A8974D6E447
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.44 139.595 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
9B554201-4E20-41FB-9C03-B67659B5C4CA
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.142 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6B7D2987-C9E2-4534-BA41-E614B5EB444E
756CC3BE-1916-4639-9DFD-4E355FC13213
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
D600274F-5111-48FD-BE56-C6FCF27566B2
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.38 170.326 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
A9FD66AF-1B8B-40FB-B3B4-3A8974D6E447
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.44 139.595 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 80DF8878-242B-4F70-892F-77645F4FC07A
B96F4850-C700-4F58-8D68-715FFB63113B
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.38 15 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
F8BFFA22-B903-4889-B2FF-9C6639EDAB40
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
AEAF474C-C465-4353-8B72-079B44AF3416
W18X40 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 21.06 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. E11A9FA9-4046-4F6F-885B-B84E82038A95
D600274F-5111-48FD-BE56-C6FCF27566B2
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.38 170.326 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
D59B5E8B-B476-4D2D-92F1-8EA3E96CD6B4
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 8.76 25 0 0 0 0.00 0.00 0.00 0 0 1842.87 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
FCE74F5C-7E95-4F46-9C0E-0F0DD1E95B00
W21X68 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 25 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 08410363-4CB8-4991-8A55-247E3759DB6D
9B554201-4E20-41FB-9C03-B67659B5C4CA
W21X68 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.142 0 0 0 0.00 0.00 0.00 0 0 1852.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
48910073-C648-4C79-9F0E-CDEB6DCCD3A4
W18X40 W14X120 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 26 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. 1DEA353D-033A-46DA-BEBE-A85844DA8E76
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.50 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
BBBCBDC5-670D-4FB4-9FBF-08475A340BD4
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 19.88 14 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Connections framing too close to each other. B366A726-300A-4677-B914-2FEC6C93CBB6
1D961F96-411A-4727-87BD-7D8A18A1F63F
W16X26 W14X61 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 19.88 19 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 8CA384CD-63A7-45E9-999F-804A4789C52D
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
1FA52551-429C-4FE3-9ADE-6103A6ADD729
W16X26 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.53 15 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
5EB74A84-B5D3-4626-94FC-BE97046F3578
W21X122 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.26 25 0 0 0 0.00 0.00 0.00 0 0 394.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. B6696E9B-03DD-4B45-BE1C-79AB81558C51
AC391EC5-1AE1-47CE-93D8-EC753652C5C2
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 9.93 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
B1FDCED3-92AA-43EB-A47C-440F2C29E99A
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 21.17 25 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. FA2B20A3-4E75-4131-91A7-A614CFDFC746
44F4ECEB-4019-4CCF-9644-99195C7DBF03
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. 351414C5-D457-4592-97B4-84B572A89BDF
C6BD7B0E-FCD8-4225-B515-5F0C0B67C7E8
W21X55 W14X257 BEAM_TO_COLUMN WEB 0 0.00 67.01 0.00 0.00 31.06 35 0 0 0 0.00 0.00 0.00 0 0 231.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
1D0C6816-70F2-4F04-821A-B92F7C1533F8
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
22CDA226-78CF-4C8F-8DB6-D4D678B63B83
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 28 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
6F37001C-CC35-4905-9DB9-73EA829D95F5
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. EFDE2B89-981B-433F-8CD6-17ED3BF4C148
0BED20DE-5349-42DC-8FE3-2865DBD90D9B
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 55.0623 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
BF36DF3B-3C1E-447F-A20B-CE8DDE172A9F
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.40 169.849 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 28.27 15 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
8844EEB4-C37F-45E9-85FF-C6AAAB4CB52D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.41 139.998 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. DBCF94F7-3931-4CEE-AAD5-853E22487073
239B7ACC-6EA7-4D43-AE1B-50EE332512E3
W18X35 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 30 0 0 0 0.00 0.00 0.00 0 0 1848.75 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
EF123453-B334-4C60-9DE6-59AB3F1B3CBF
W16X31 W14X342 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 226.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
C85369ED-5920-45A5-9F03-97F3C04D9053
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.31 171.469 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
F7E75267-5AAE-4903-9D0D-8A6597D9DEAF
W18X40 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.97 30 0 0 0 0.00 0.00 0.00 0 0 390.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 917863AE-38CE-4B33-AEDF-2CC85843B14F
03AFCEE2-03A4-4FA4-AF68-BCB121161EFA
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 13 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
9943EA03-024C-4CF4-A4F3-7F3562E0AD59
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
54EFA1F9-4760-40FC-9B6A-73D0BAACE27A
W21X50 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 45.00 33 0 0 0 0.00 0.00 0.00 0 0 1851.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 4E860B32-D2BC-496D-820D-93AC7D54BF55
76D141C1-ECEE-4788-8726-50C2028CC89C
W18X40 W14X43 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. 4E860B32-D2BC-496D-820D-93AC7D54BF55
C5DFCC2A-AB41-4AE6-BA45-244A2DC38D64
HSS6X6X1/4 W14X43 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 6.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
2F98CFCC-20C6-44D5-8A9F-F91435BFB3EE
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 28.27 56.4825 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
6C40D808-40C2-45BE-BE42-286EE62CAE44
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 33E416D9-5637-4A34-8A4E-F9A73FEFE321
837EBA43-8547-4950-875A-672030161388
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
78DEF81C-8DB3-43F0-BFD2-EA15EAA1DAD9
W21X68 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 0.00 0.00 29.00 10 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
5899F98C-1A76-47B6-A0FD-66B9CF5FD514
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 11.50 138.853 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
349CC7F8-F40C-4448-816B-00D5C6524398
W12X14 W14X211 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 10.65 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Load computed with UDL is too high. 6546C29A-342F-41CF-A35B-B0B8A8121786
A07C8732-95E3-4B82-96D5-693FF784822D
W21X68 W14X211 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 9.50 168.085 0 0 0 0.00 0.00 0.00 0 0 393.875 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Supported connection type not found 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
9C13A6B6-FE45-4DB6-844F-777976510FE2
W18X35 W14X145 BEAM_TO_COLUMN FLANGE 0 0.00 88.05 0.00 0.00 35.88 25 0 0 0 0.00 0.00 0.00 0 0 390.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
37B7C198-D6FE-43A0-A5A8-4A56219C4E40
W21X68 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 25.00 30 0 0 0 0.00 0.00 0.00 0 0 1852.12 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Qnect does not yet support HSS filler beams. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
76D141C1-ECEE-4788-8726-50C2028CC89C
W18X40 W14X68 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 20.00 30 0 0 0 0.00 0.00 0.00 0 0 1848.88 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Framing condition is not yet supported by Qnect. 06EFA10C-AC85-48E2-BB76-4CDD620AB53F
82621609-0930-4A7A-90E7-335A0781A457
HSS6X6X1/4 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 90.00 6.00 0.00 1.60 64.1045 0 0 0 0.00 0.00 0.00 0 0 1834 A992-->A992
A500-GR.B-->A500-GR.B
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
973C2E2B-E36F-42DC-B124-77DA0D022762
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 27 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
C2667425-7FE3-43DB-B0B6-1D3A1E4ED965
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 388.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
CFDFBFD6-6E56-4709-B762-C20275E05F4D
W12X14 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -90.00 0.00 0.00 7.85 12 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
1AE3987A-FBFA-4479-BE1A-F6142F8F33F2
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -90.00 0.00 0.00 15.95 12 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
821521D9-8B35-497D-A9B2-11DDBF27AA6F
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 396.375 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
CE568E02-A0A7-472A-8E17-8219D9C19567
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 402.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Non zero horizontal offset beams not supported. F5FC6427-D2C3-420B-AEED-31A7034FC390
4897A67D-6F4F-4B35-B20A-B62C996F935F
W16X31 W14X211 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.16 31.21 19 0 0 0 0.00 0.00 0.00 0 0 388.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
CFDFBFD6-6E56-4709-B762-C20275E05F4D
W12X14 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 7.85 25 0 0 0 0.00 0.00 0.00 0 0 384.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not enough available space for fillet weld. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
0E0C2230-66CE-4BF4-AE6C-D55B6DA041FA
W18X60 W14X120 BEAM_TO_COLUMN WEB 0 0.00 68.04 0.00 0.00 21.56 27 0 0 0 0.00 0.00 0.00 0 0 391 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 79332908-E18B-4B89-A777-5FB4F6F3EF4C
61C6EF8F-F70D-4A29-A6B5-CE6413D750E5
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. ED470781-19F2-4212-B5DF-A6C96B2CBECD
FA2B20A3-4E75-4131-91A7-A614CFDFC746
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
F5FC6427-D2C3-420B-AEED-31A7034FC390
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. BE86D4E7-2CA5-4CB6-9431-C640068DA113
9891A6D6-73F2-4A01-84C5-5A080393E4D6
W14X211 W14X132 COLUMN_SPLICE NONE 0 -90.00 -0.20 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. FE5E2D5C-1417-4F24-9C81-A9255AA51F04
BCAB2633-C665-4DE9-B005-3F8AC0C1711F
W14X120 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 58B83107-5F20-447B-BEB8-A86F72651EE8
BCAB2633-C665-4DE9-B005-3F8AC0C1711F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5C931518-5A05-44EF-A718-E925BB7B94B1
A5437CD8-CE09-438A-A04C-FB59A8C75582
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 18F297E5-76DA-4E32-B991-C804795ED9DF
8915B579-96F9-4355-B4DD-930B01D8E275
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D4A1D721-263B-4B57-A711-206DD3636F2B
C3B6AB56-9E79-4303-AA53-4BED52DCD9E7
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 976194EC-3885-4F9C-8AD2-F926CF6886B0
C3B6AB56-9E79-4303-AA53-4BED52DCD9E7
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 94ECA3BE-EB62-4102-ACA2-674291E7218F
1DEA353D-033A-46DA-BEBE-A85844DA8E76
W14X120 W14X99 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 73E6E23C-7288-4366-8F2A-C22BA1B24AEA
1DEA353D-033A-46DA-BEBE-A85844DA8E76
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8A9EFCA4-743F-4278-AE8F-610C35E3BED7
D5088096-F760-49AD-915F-741618902EA1
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 7D86E4D7-F48D-456E-AED4-F1499B20B2A0
A9108DB3-8258-4090-BDB0-524D8A7E9B2E
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 198AB2FC-84F3-46CF-9FED-891A7AA29A3B
A9108DB3-8258-4090-BDB0-524D8A7E9B2E
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. F3EDEC65-A90D-4898-A5D1-046B4CFDF563
68BE7F80-CC6D-4762-8DE0-8BEFE27DDAC1
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 3A559CBD-55AD-48E6-A670-10E89C408100
67A81924-72A4-43E9-B3A6-775B5F8AD939
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0BE130D6-D18E-4612-A1E3-F919413279E7
F9375DBA-442E-4B6E-A6D3-D93EB86939C4
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4CCC0250-FFF9-4AF5-8ADB-A75B2E1DB6C3
3698A971-46FC-45EC-B1A8-738CD75AD4EA
W14X257 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4FEA724E-F0C3-4ACA-AFD8-137B8083615C
9D887600-96CA-43B3-8049-3885ED21ED88
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 04DAC6B5-7CAF-4DCF-B790-81EB699E3D41
9D887600-96CA-43B3-8049-3885ED21ED88
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A94E9FCD-F10C-4D9A-A3D4-F02118D4E31A
1FD7B2FE-F5B1-4F0E-859E-61529BE79B2D
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. DE3AE352-A80E-4E1B-B863-3E4F52C83D1D
7A54241B-B68E-4262-8210-0BF51F369A96
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 459BBA95-146B-4DE4-A455-A3A8868F8746
B842C0CA-3A81-4DE0-B3D7-4D6797A042E3
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E1AA0701-83E0-4233-A3D9-53AC4118EBEF
B842C0CA-3A81-4DE0-B3D7-4D6797A042E3
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 9DBDF860-DBFF-4712-AC7A-3A30D8948579
30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 199D1626-4144-4159-A452-3F754AC2FDBD
54AD2023-4C50-4297-B4DF-563A9E989945
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 254E104A-3A1C-4C1A-9853-5744B3552047
31F45CAB-2F14-49FB-ACB6-F07F723118E1
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A60F7B4B-4394-4A19-AA71-DC997EA1EA03
31F45CAB-2F14-49FB-ACB6-F07F723118E1
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. FBDD1DE5-2076-499D-89BE-EF02E3288EE7
4D858208-2A09-4220-BD30-DA2C2FEAB613
W14X90 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 22.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 005F3640-AFC1-435A-AF8D-2DAD03959EF5
509F58E7-4085-4E46-9D52-3A072858BDD4
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 7CC96676-4A04-4BE6-B285-A3C9C388FA7F
3F046788-938E-4777-9214-19960D7B760D
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
E0D13FA7-A11F-413F-B5FD-B0545E2B2238
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 1868988C-8768-4AB5-91F9-4C00E69AA95B
F5FFA8C1-21B4-4522-9E3C-33D2A82A168D
W14X99 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 9E5D1E92-A781-4F41-92D7-CCA344D03054
F5FFA8C1-21B4-4522-9E3C-33D2A82A168D
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 2308FF66-29E7-4677-95FC-42AB59DCB43A
766D3CAE-807B-4731-9946-E94B317FDEB7
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 25DDB5D1-4BAC-400F-9D61-C93C00725C38
04E9A7D2-F801-4C42-9930-95E386919649
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5748D66D-3604-46A6-9B2D-C17F09765DEB
6B12E975-80E0-47C2-9110-05B3C2D34B65
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B608D27E-FA9A-40A5-8E55-290C103F50A9
6B12E975-80E0-47C2-9110-05B3C2D34B65
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. 256EEFF9-D368-46E3-86F4-5760B6CE745A
D5B94786-A91C-4967-982E-220EF3465CED
W30X108 W14X176 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 44.92 41 0 0 0 0.00 0.00 0.00 0 0 240.625 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 256EEFF9-D368-46E3-86F4-5760B6CE745A
E0D13FA7-A11F-413F-B5FD-B0545E2B2238
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. EBFF3E23-0757-417D-BE1E-C3ACE8309E71
FCF3AA38-817B-4829-B781-E965BEE60434
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. AC593D77-2AB3-4FE4-B89C-230A1CD2750E
48EE061A-7EB8-4AA0-B548-FBEF06C6141F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 36B0F1CB-615F-47C7-AB19-E1A13B93CF5B
B9FEAE65-02C3-4DEA-96B1-8A1214E30635
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 9DFB3A01-1130-41C7-82E4-33B818916AD2
87E53653-BDD3-4B75-A233-9DB3B3149B1D
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E4FE6769-C272-4974-8777-AA845DD7091E
D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A254393B-C4CA-46A8-BE5A-5DA128358058
D43C3FEC-2D15-4FA3-B79A-1FE0A1BADA28
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. DCC44A0E-8A76-4E4F-A8B8-9765BF950560
33E416D9-5637-4A34-8A4E-F9A73FEFE321
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8609346E-C1F4-4A5B-881C-02AC6DE98EB5
917863AE-38CE-4B33-AEDF-2CC85843B14F
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 2D511FE8-D6A2-4A4C-9F32-F054BB297AEF
9CA600FE-0339-4342-8695-B6231F25261A
W14X211 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B0B80451-F865-4A64-A7FB-F2AB4C88D9F3
B366A726-300A-4677-B914-2FEC6C93CBB6
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5982A642-8B41-4653-A458-5D49468A0CBA
52A60369-0465-47E3-AB4C-9C78FEE3FF19
W14X211 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D44E128C-50BE-4E19-AB8A-2A860B99D2E9
B6696E9B-03DD-4B45-BE1C-79AB81558C51
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0DC49D64-D312-4295-980E-8186405BADF1
6546C29A-342F-41CF-A35B-B0B8A8121786
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
33E416D9-5637-4A34-8A4E-F9A73FEFE321
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
917863AE-38CE-4B33-AEDF-2CC85843B14F
W14X211 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 1AA81CB9-0E1C-48F4-9936-67143001393A
97E0D34E-2FC7-4F4B-82C9-61BAB429A9E5
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E82B6EA4-9DFE-47FF-B9D0-F16534E8AFDF
79332908-E18B-4B89-A777-5FB4F6F3EF4C
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 439CA6BB-CDAB-47D7-8146-8872A3F7D0B0
234B93AF-4538-475D-9E47-9CC39023D2EB
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D138E37E-1C12-4A9C-BDAC-499BE81AAD51
1FD7B2FE-F5B1-4F0E-859E-61529BE79B2D
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C29CC7BE-FEA7-4F7F-BB3A-2FA142502627
A60F7B4B-4394-4A19-AA71-DC997EA1EA03
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. EDFEBF8B-4EF8-4ED0-9ABB-8ADB5B5AAA66
2D511FE8-D6A2-4A4C-9F32-F054BB297AEF
W14X311 W14X370 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 48.2499 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0BE130D6-D18E-4612-A1E3-F919413279E7
5C925D0A-3A93-4004-AB00-E1CE70D77408
W14X311 W14X211 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 264.004 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5C0B86DC-D2F2-4DD2-AD23-303D10C3F2D2
5C925D0A-3A93-4004-AB00-E1CE70D77408
W14X311 W14X342 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 17.98 0 0 0 0 0.00 0.00 0.00 0 0 48.2504 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E05842BC-DDE3-467F-B92A-D2C54AD3EA95
D0BF0B8B-C43A-4741-989E-6BB05970F7FB
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. EA19C6D6-2E82-4892-B19C-54412AF51462
499094DD-41A4-4EA3-8B57-D1D407C31029
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B1CEBEA6-756E-4E0F-8182-2CCAF74CF5D7
6BBACA91-E210-4AD8-B97D-3AA96A9E7C5C
W14X90 W14X145 COLUMN_SPLICE NONE 0 90.00 0.13 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 849D18B6-F17A-437D-81B4-ECB9779C307A
B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 17E69F5F-14F4-404C-BAAE-5A32DD5B7917
94ECA3BE-EB62-4102-ACA2-674291E7218F
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 25BA3283-EA02-4EFC-ACC6-499E0E2B7005
21F19F0B-25B6-4426-831E-9221191F7162
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5B3C998D-633E-447A-8436-E91E75DD52F0
0A0DF5C0-DE73-42DD-82F9-860DF3D4D4DB
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 71FBF6F6-23D9-4C7E-9BD5-9B76430869A8
A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 804F6CE5-8C92-4234-A4A8-EE007080E0D5
014E5A3F-A64E-4D67-837C-F7685A5B6952
W14X257 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4D1C1EC7-81D8-43C9-BD46-45F1D0E4AA02
E56A7BEB-870C-414D-B0E6-DA41BF1E9951
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.56 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 2052876E-1823-4CF9-A5A1-E235327D49D1
3A559CBD-55AD-48E6-A670-10E89C408100
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 718E8E4E-23D8-4490-A309-35C41B5857A0
A47F26D3-3A1D-47DD-A0ED-05FF144987F1
W14X109 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 2637778C-DE1B-48B7-9307-B6293C398AE8
274315DF-2A98-467B-9E3F-3340BD4F59F4
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
B5A12E3D-7B9B-4962-8D6B-10C2212F9F5B
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 39.25 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8672619A-330F-427F-B90E-D5FA7749380E
0A4413E4-EEA3-4095-B9FE-32B9E56B12F5
W14X233 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 1EE71A45-4E74-4978-9FDB-1DF8F3919990
A0B18C57-F5A1-4D6F-8553-695CDB252E2A
W14X61 W14X48 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 51414106-205D-4331-85F6-80A08C0EB129
A0B18C57-F5A1-4D6F-8553-695CDB252E2A
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E3FFDF1E-EFA5-4A96-B5DE-1478BD524BB8
8CA384CD-63A7-45E9-999F-804A4789C52D
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0F146864-E5A0-42D6-9916-0AA6FCC7B460
3B4917E8-C019-4738-83DF-DF3E853F06F5
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8F270805-1B17-4B64-A29F-CF9790DB0E5C
C9F26F38-EC3D-4EFF-9674-BD58106FA0E1
W14X257 W14X311 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A3B9DA33-3DBF-4B64-A3F5-1E976DA661A1
F74B3939-90CD-46C3-9CC5-2A56C3DE1DA4
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 014E5A3F-A64E-4D67-837C-F7685A5B6952
2467842A-34B5-4239-88D0-08878BDBDFB3
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 36.69 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B5A502CD-C6CF-4863-865A-5F9F287F09C6
53853856-6604-43D0-A41A-01558C77B81D
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 99293E55-552F-458D-BE0D-8AEF4F12BA9B
04DAC6B5-7CAF-4DCF-B790-81EB699E3D41
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0A0DF5C0-DE73-42DD-82F9-860DF3D4D4DB
18CD6EE1-AE5C-4C60-933F-92FCA78A859C
W14X53 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 11A61282-48D3-436E-848D-14A7DCACA19E
FE5E2D5C-1417-4F24-9C81-A9255AA51F04
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B5BE23C0-4522-4BDB-8E47-0F43244B58D0
4BCA48E0-FE5F-48A2-AB7B-D6AE926C4201
W14X145 W14X176 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 66FFFA38-CAF9-4665-B00F-A08260F332DF
E823BBFD-103C-4562-8321-E61691DA5016
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 39.25 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D87A76C1-2CE9-4AA4-9592-65AAD8975AE0
AA759B66-B163-41C5-8DDF-AE56C1F84BD1
W14X257 W14X233 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 37.13 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 274315DF-2A98-467B-9E3F-3340BD4F59F4
728BCB88-307A-4127-B12C-009280BAC82D
W14X90 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 24.73 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 857B257E-6DED-42D3-A72C-4697CA4480AF
6E7617B0-54CC-45C4-853A-1F013E64C550
W14X61 W14X43 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 1868988C-8768-4AB5-91F9-4C00E69AA95B
6E7617B0-54CC-45C4-853A-1F013E64C550
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 85D8F200-BC22-4D70-A06F-09BDA98BBB38
9A43B315-F54F-4EE0-819F-F5748C979535
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.54 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C29CC7BE-FEA7-4F7F-BB3A-2FA142502627
2ECEC8F6-06D2-496F-8E27-AFEF34276840
W14X43 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 6F5B61CE-BF3C-4ED1-A8D2-1CF234A78487
6D23561F-58EC-4295-BEE5-00A1A2EB6173
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A94E9FCD-F10C-4D9A-A3D4-F02118D4E31A
A651599F-786B-4CBE-BF42-8E36DB79C3AD
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A37ED7B7-1F1E-4221-854A-22E084052C34
213704B6-293E-4CA5-ADD6-B558F50C559D
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
2BAE0A0B-E0B3-4569-B1DD-6E9E654A6B62
W14X120 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. DED0233D-B38B-46D3-9A14-0D2DD964607C
C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
W30X108 W14X120 BEAM_TO_COLUMN WEB 0 0.00 90.00 0.00 0.00 44.92 41 0 0 0 0.00 0.00 0.00 0 0 1212.63 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. DAA426C2-C841-4BA6-A704-EFEF817CC8DB
22FCAB24-283B-4790-85CF-D3E541B41664
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 134936D7-07A4-41B1-A8DE-EF7052CB2656
313E3F6D-87A2-4330-8BD4-7291B3E9511D
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 36.06 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5ECE6F2E-78AD-4838-9911-EFB264999596
E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
W14X120 W14X90 COLUMN_SPLICE NONE 0 -90.00 -0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. BE86D4E7-2CA5-4CB6-9431-C640068DA113
E25B4FEA-5A86-43AA-8F88-67E60F60A7FF
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. DE3AE352-A80E-4E1B-B863-3E4F52C83D1D
776B310A-DBC0-419D-97AF-AAB6EE882274
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0D102D6C-E337-4D1D-A0C6-DF1CEEEFE55F
0DDE526F-4027-4C3D-9971-C7C84A4DF35C
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5748D66D-3604-46A6-9B2D-C17F09765DEB
4905A174-F477-4655-A0E4-D1EEB324BD23
W14X120 W14X120 COLUMN_SPLICE NONE 0 90.00 1.42 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A825CA09-646F-4F0E-A88D-C195109686C6
CDE31233-C3C7-4CBC-8918-8C0842DF2791
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D4A1D721-263B-4B57-A711-206DD3636F2B
C685F2B8-A6FF-4398-9B6E-7A877FF10113
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 7D86E4D7-F48D-456E-AED4-F1499B20B2A0
38EDDDC4-866F-44CE-BD8E-AAB3CFF6FFE7
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 975BA93D-8B91-4FAC-8FD1-22145813F256
DBC72FA1-D71C-4823-9A42-17862FEC23B2
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0EDEBE74-842C-4C52-804E-B50CC340296B
9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. F9375DBA-442E-4B6E-A6D3-D93EB86939C4
E168056A-8C92-4709-BDE8-4979BA5C6259
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 5757E5AE-D1C3-4C0F-9B83-717509C993C1
96B87704-8949-45CC-B092-EB20FB25B31F
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 3EF528DA-76E8-4B14-B1E3-696A796126E6
8152E62A-47CB-479D-A4C7-ECCF842B45EA
W14X120 W14X159 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 1EE71A45-4E74-4978-9FDB-1DF8F3919990
68AF7010-8250-4FCA-9003-31E8DD0E88C2
W14X43 W14X48 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 18CD6EE1-AE5C-4C60-933F-92FCA78A859C
D7D8F5C3-F5CD-4EBA-9149-3201EBD95C77
W14X53 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 11A61282-48D3-436E-848D-14A7DCACA19E
9CE6EB0B-EAF3-4FF6-873D-BD8DB74FD3B6
W14X53 W14X74 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 2637778C-DE1B-48B7-9307-B6293C398AE8
ADFE58A3-0F4A-44FC-B5FF-98E8488A18CD
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. F9F6C52F-4EDB-46B7-A491-6CDF3350ECC9
B76C4CD9-E923-4CA3-B6DF-58C8DF0EABF7
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E4FE6769-C272-4974-8777-AA845DD7091E
E02CA80D-FC59-4556-B8EE-65046563BC1A
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 66FFFA38-CAF9-4665-B00F-A08260F332DF
ABEE8C90-15B1-496B-A85C-EE3B3CDCBCE1
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 749.754 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0BE172C5-6C31-4CAD-98FC-BEAF6FEE878D
BCA24E27-99E9-4C19-91AD-8602025D509F
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.78 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B9FEAE65-02C3-4DEA-96B1-8A1214E30635
7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 746.243 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 1E08BF51-F015-4461-8A0E-C73E08553BCE
41CD1199-5009-48D1-A5A3-FF28C3976D73
W14X109 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4D272FF9-FA56-4468-89E4-F6FA5735A05B
AE197D6F-29DB-4952-8FA8-91DB5DCFD553
W14X120 W14X132 COLUMN_SPLICE NONE 0 90.00 90.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.17 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4D5B338E-7968-48D1-9BDB-20093C0CF8B0
28C5BA0D-415B-4012-BCAB-FC953FEB85E0
W14X145 W14X193 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1233.13 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C6FC0258-DCB5-4EBD-B503-598DCEEDA2A9
4E860B32-D2BC-496D-820D-93AC7D54BF55
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0DDE526F-4027-4C3D-9971-C7C84A4DF35C
4B975AA9-C7BE-4936-BCCE-89148831E8CB
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 89.41 0.00 0.00 9.06 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 234B93AF-4538-475D-9E47-9CC39023D2EB
0807590A-F1FF-4219-9E8D-5634D9FB6D77
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E168056A-8C92-4709-BDE8-4979BA5C6259
330773F5-4848-43C6-825B-2A3F6107354B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 2263.27 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
90D3759D-A468-44EC-8E1E-D8C401E416DB
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
D2EF0942-F263-4253-BC4B-B59575638260
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B76C4CD9-E923-4CA3-B6DF-58C8DF0EABF7
E7058D14-9D97-4EDD-A51C-89B97DE7273B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8152E62A-47CB-479D-A4C7-ECCF842B45EA
13699A5D-FF3F-4C95-AD7C-E0A39B386076
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 96B87704-8949-45CC-B092-EB20FB25B31F
E11A9FA9-4046-4F6F-885B-B84E82038A95
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E02CA80D-FC59-4556-B8EE-65046563BC1A
80DF8878-242B-4F70-892F-77645F4FC07A
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 9BF70E1B-A9FF-488C-B77A-EBD0BFC4EE38
6B7D2987-C9E2-4534-BA41-E614B5EB444E
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.52 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 16108B12-3ED5-4562-B5B1-03AAD09FC446
ED50100C-D93B-43EB-972A-70EDBA07BF0E
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. CF07F7C4-B4D1-4144-B718-102215DF7786
64AE8F49-4E1E-4611-939D-C22BF7153D67
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. CDE31233-C3C7-4CBC-8918-8C0842DF2791
EFDE2B89-981B-433F-8CD6-17ED3BF4C148
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 38EDDDC4-866F-44CE-BD8E-AAB3CFF6FFE7
06A762CD-6FFA-4D78-8266-515E368F9689
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 456239D1-6988-418B-9D36-C38E6C17CA05
3449F51F-9875-41AF-B0EB-CC4113E034DE
W14X61 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 429C8C48-CA88-405B-8AF1-B545D954B2AE
A0990116-875E-4BFF-A230-6FB982ADB335
W14X68 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 519FDEFE-13BD-46F9-8644-7D891121E73C
3FB8FB5A-E6E2-4140-824C-055B07B10A46
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E9CBDE30-BE05-4801-8593-128620AE5C7D
354255C4-13C1-46BD-BA52-8560A1359BA6
W14X145 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D2CDAB23-BFC1-4CA4-8410-378E31F3A209
59D4C6F3-8A47-4609-99C8-2B08E70B31ED
W14X48 W14X48 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A2915901-C53B-4A9A-B9DE-9F1FCF4D4C9E
8D0E40CF-D698-4738-BE89-65CC343BF67E
W14X43 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 035ED350-53E8-4774-BDA6-DA87F9D1E2EB
7A54241B-B68E-4262-8210-0BF51F369A96
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.949 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 318A24E1-4A86-4E34-BD86-6ABA04648AAB
4326ED42-B1A3-42DD-AB36-B7AC28C3D5EE
W14X53 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 13C6FBA8-D028-4B31-9D3F-5D111A5CD0F0
79FD091A-B1CE-4014-A0A4-6E3A91F6AB14
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 8.40 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. E56A7BEB-870C-414D-B0E6-DA41BF1E9951
9258B322-7F52-4655-AECB-8BBBCB754CF5
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.16 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1229.52 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 9258B322-7F52-4655-AECB-8BBBCB754CF5
4D272FF9-FA56-4468-89E4-F6FA5735A05B
W14X132 W14X193 COLUMN_SPLICE NONE 0 90.00 90.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.5 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 48EE061A-7EB8-4AA0-B548-FBEF06C6141F
DBCF94F7-3931-4CEE-AAD5-853E22487073
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 0.00 0.00 0.00 46.65 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4905A174-F477-4655-A0E4-D1EEB324BD23
4E134221-1035-49CA-B35E-A781B5D4DEBA
W14X109 W14X120 COLUMN_SPLICE NONE 0 90.00 1.05 0.00 0.00 24.04 0 0 0 0 0.00 0.00 0.00 0 0 1723.34 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. DA9F25BC-167E-4DE7-A9FE-0BDC46482C0F
8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.009 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8AD1664C-F7C8-4AA4-8C1B-6DD73CB0A681
96FEE1F7-7165-4EFA-8E9F-895881561ACC
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 0.21 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 748.774 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 351414C5-D457-4592-97B4-84B572A89BDF
9891A6D6-73F2-4A01-84C5-5A080393E4D6
W14X211 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 265.021 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. CBB5B214-3E9E-404E-AB4C-CD89D2FBC6F6
F5FC6427-D2C3-420B-AEED-31A7034FC390
W14X211 W14X342 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 263.483 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 68AF7010-8250-4FCA-9003-31E8DD0E88C2
6183D7E5-CFCA-4136-ACC8-792EC36CB012
W14X43 W14X43 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 36.68 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A37ED7B7-1F1E-4221-854A-22E084052C34
4A851DC9-81A8-430C-9E92-B0040852819A
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. FA2B20A3-4E75-4131-91A7-A614CFDFC746
4A851DC9-81A8-430C-9E92-B0040852819A
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D5088096-F760-49AD-915F-741618902EA1
687731D8-D93F-4369-A84B-AE8EC61D855A
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A5437CD8-CE09-438A-A04C-FB59A8C75582
A825CA09-646F-4F0E-A88D-C195109686C6
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 456239D1-6988-418B-9D36-C38E6C17CA05
E9E2186B-1328-44FC-A23E-06A54FBF638C
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 3F046788-938E-4777-9214-19960D7B760D
E9E2186B-1328-44FC-A23E-06A54FBF638C
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0BE172C5-6C31-4CAD-98FC-BEAF6FEE878D
7E865AC3-7CD2-4EE5-BD4F-09E74E4485A4
W14X193 W14X132 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Part of group with Not connected due to being a column splice connection. 0A4413E4-EEA3-4095-B9FE-32B9E56B12F5
B4047916-F629-490E-A1C9-F1A1216D9BA0
W14X193 W14X233 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1235.99 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 16108B12-3ED5-4562-B5B1-03AAD09FC446
B4047916-F629-490E-A1C9-F1A1216D9BA0
W14X193 W14X145 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C4492C55-333F-4524-A162-75AAC54BCC30
47A1B78B-9A15-4D5D-A8C0-15E1ABEF088B
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 3B4917E8-C019-4738-83DF-DF3E853F06F5
47A1B78B-9A15-4D5D-A8C0-15E1ABEF088B
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A3B9DA33-3DBF-4B64-A3F5-1E976DA661A1
3C3C0857-2A00-4ACE-94D3-67DC25F096E2
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8915B579-96F9-4355-B4DD-930B01D8E275
3C3C0857-2A00-4ACE-94D3-67DC25F096E2
W14X90 W14X99 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E05842BC-DDE3-467F-B92A-D2C54AD3EA95
D462CB20-218C-41E3-A4FF-E9488A8B1861
W14X90 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A47F26D3-3A1D-47DD-A0ED-05FF144987F1
D462CB20-218C-41E3-A4FF-E9488A8B1861
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. FCF3AA38-817B-4829-B781-E965BEE60434
4C2D5349-D1BF-44CB-B18B-E237F9E8ED9C
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 608A8D89-92CE-420D-A377-B0B0A969C19D
13C6FBA8-D028-4B31-9D3F-5D111A5CD0F0
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D2064BCF-9BD5-46A1-85D5-AEED10AE8551
A4B7B146-0337-4286-B35F-D8B15F1A4FDB
W14X211 W14X283 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 264.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 608A8D89-92CE-420D-A377-B0B0A969C19D
6DA25684-81FD-4DB7-9AE4-ABA3CB9A9A40
W14X99 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. CFD14E8A-055D-48E7-AEF8-7CEAC63E3845
6DA25684-81FD-4DB7-9AE4-ABA3CB9A9A40
W14X99 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 264 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4BCA48E0-FE5F-48A2-AB7B-D6AE926C4201
DAA426C2-C841-4BA6-A704-EFEF817CC8DB
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 0DDEE9E7-03E6-4812-A4C1-F06AC8876D53
9070ACE5-AF7E-4667-9DBD-8AB7C8365DD9
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 766D3CAE-807B-4731-9946-E94B317FDEB7
9070ACE5-AF7E-4667-9DBD-8AB7C8365DD9
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 96D43969-72D6-48D4-A185-6FA61BE85F1F
B4010245-3B7C-4CAA-95ED-A836EF7C3344
W14X90 W14X82 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 52A60369-0465-47E3-AB4C-9C78FEE3FF19
F9F6C52F-4EDB-46B7-A491-6CDF3350ECC9
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 318A24E1-4A86-4E34-BD86-6ABA04648AAB
4EEFEF1C-2E0E-497B-9EC2-97EC40BEC890
W14X90 W14X68 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 68BE7F80-CC6D-4762-8DE0-8BEFE27DDAC1
4EEFEF1C-2E0E-497B-9EC2-97EC40BEC890
W14X90 W14X109 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. F3004609-63D0-420E-B92C-2AEA3D319B66
113ADEAB-1E0C-4E18-83F3-F64DD28473FF
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 8CA384CD-63A7-45E9-999F-804A4789C52D
113ADEAB-1E0C-4E18-83F3-F64DD28473FF
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 9CA600FE-0339-4342-8695-B6231F25261A
3EF528DA-76E8-4B14-B1E3-696A796126E6
W14X159 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
31137C4F-3F63-438D-AFDB-7950376A8126
W14X53 W14X53 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B366A726-300A-4677-B914-2FEC6C93CBB6
31137C4F-3F63-438D-AFDB-7950376A8126
W14X53 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. EA539FBB-004F-446D-B763-D2D5DAF4CABE
ABEE8C90-15B1-496B-A85C-EE3B3CDCBCE1
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 0.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1235.51 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 509F58E7-4085-4E46-9D52-3A072858BDD4
B4010245-3B7C-4CAA-95ED-A836EF7C3344
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 97E0D34E-2FC7-4F4B-82C9-61BAB429A9E5
5DD876A1-A3FF-4464-8BA9-041F810834A8
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. EA19C6D6-2E82-4892-B19C-54412AF51462
695DEE27-D1D4-4359-BA69-F51FC052A6A5
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B4A8BBE6-B523-4B01-8AAA-7FFD0943DD97
695DEE27-D1D4-4359-BA69-F51FC052A6A5
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. FC9AE33D-E8B2-4209-B8FB-2CDA0A905896
CEA25DD3-355C-4167-9323-9C662177C0D1
W14X68 W14X61 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 54AD2023-4C50-4297-B4DF-563A9E989945
CEA25DD3-355C-4167-9323-9C662177C0D1
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 697AF9C6-D06C-4821-B156-FA00822F4358
9BF69AC7-B5FC-4B4C-98C5-4CAF68B9C641
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C9F26F38-EC3D-4EFF-9674-BD58106FA0E1
9BF69AC7-B5FC-4B4C-98C5-4CAF68B9C641
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 30DD6DED-FC63-4AAA-94C1-65D0EFCF754C
134936D7-07A4-41B1-A8DE-EF7052CB2656
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 429C8C48-CA88-405B-8AF1-B545D954B2AE
50546E67-F121-4E6E-98C4-D115C89553F7
W14X257 W14X257 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A4B7B146-0337-4286-B35F-D8B15F1A4FDB
0D102D6C-E337-4D1D-A0C6-DF1CEEEFE55F
W14X132 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. BFEE8ADB-BB96-4E92-BBE8-B52C6A6B5ED4
E9CBDE30-BE05-4801-8593-128620AE5C7D
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 4C2D5349-D1BF-44CB-B18B-E237F9E8ED9C
F8936F8C-437A-4661-AF27-2EAC8E077DFB
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. FC9AE33D-E8B2-4209-B8FB-2CDA0A905896
7AF1A487-25FD-474C-ACFA-2872A3AE369A
W14X43 W14X61 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. F3004609-63D0-420E-B92C-2AEA3D319B66
08410363-4CB8-4991-8A55-247E3759DB6D
W14X90 W14X120 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 45.46 0 0 0 0 0.00 0.00 0.00 0 0 1722.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 45D1C36D-56B2-492D-8DD3-31BA99C7D777
35B36F33-6288-429B-8D92-DA2A0B197C57
W14X43 W14X53 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 24.06 0 0 0 0 0.00 0.00 0.00 0 0 1722 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 67A81924-72A4-43E9-B3A6-775B5F8AD939
C6FC0258-DCB5-4EBD-B503-598DCEEDA2A9
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 61C6EF8F-F70D-4A29-A6B5-CE6413D750E5
CF07F7C4-B4D1-4144-B718-102215DF7786
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 3698A971-46FC-45EC-B1A8-738CD75AD4EA
BFEE8ADB-BB96-4E92-BBE8-B52C6A6B5ED4
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A075BEC4-E3BA-4ADD-A4B4-FF38334BC8AD
50546E67-F121-4E6E-98C4-D115C89553F7
W14X257 W14X257 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 519FDEFE-13BD-46F9-8644-7D891121E73C
3E7509DC-FDAC-4C5E-921A-3222F6C2680E
W14X109 W14X90 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 21F19F0B-25B6-4426-831E-9221191F7162
3E7509DC-FDAC-4C5E-921A-3222F6C2680E
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 87E53653-BDD3-4B75-A233-9DB3B3149B1D
975BA93D-8B91-4FAC-8FD1-22145813F256
W14X109 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. E1AA0701-83E0-4233-A3D9-53AC4118EBEF
D14C1B40-3446-429D-9383-FD0C2F23B815
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 687731D8-D93F-4369-A84B-AE8EC61D855A
85D8F200-BC22-4D70-A06F-09BDA98BBB38
W14X68 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 804F6CE5-8C92-4234-A4A8-EE007080E0D5
47A6DB92-BBD5-4DE0-AF61-41DE5780F226
W14X61 W14X90 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A2C8D2C2-1E30-4A8E-A979-1BA91CABCAFC
0EDEBE74-842C-4C52-804E-B50CC340296B
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 6F5B61CE-BF3C-4ED1-A8D2-1CF234A78487
5DD876A1-A3FF-4464-8BA9-041F810834A8
W14X90 W14X74 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B5A502CD-C6CF-4863-865A-5F9F287F09C6
AF8300FF-515D-4DFA-A6AC-B8B2971656AB
W14X61 W14X68 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. A2915901-C53B-4A9A-B9DE-9F1FCF4D4C9E
1763B868-4EC6-46BA-A989-914FD8B07FEF
W14X61 W14X53 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. FBDD1DE5-2076-499D-89BE-EF02E3288EE7
1763B868-4EC6-46BA-A989-914FD8B07FEF
W14X61 W14X82 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 750 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. B6696E9B-03DD-4B45-BE1C-79AB81558C51
DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. C2CCF94F-3ACF-48FC-8135-B241C2B922C9
A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
W14X145 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 6546C29A-342F-41CF-A35B-B0B8A8121786
A39F0F2A-1150-4E67-940D-BA5EAF0A67C2
W14X145 W14X211 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. DE70CB98-AC6F-4B1B-B9BD-BB2F32ADBFE0
9EE7EB7A-0D66-46BA-8C7D-0284BD78A6BB
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 1E08BF51-F015-4461-8A0E-C73E08553BCE
71FC28AB-78D1-4BED-9262-C73D09A3E8F2
W14X120 W14X120 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. 04E9A7D2-F801-4C42-9930-95E386919649
71FC28AB-78D1-4BED-9262-C73D09A3E8F2
W14X120 W14X145 COLUMN_SPLICE NONE 0 90.00 0.65 0.00 0.00 40.48 0 0 0 0 0.00 0.00 0.00 0 0 750.25 A992-->A992
A992-->A992
Test BL FR 2018-08-31 16:44:22 Not connected due to being a column splice connection. D2CDAB23-BFC1-4CA4-8410-378E31F3A209
AF8300FF-515D-4DFA-A6AC-B8B2971656AB
W14X61 W14X48 COLUMN_SPLICE NONE 0 -90.00 -180.00 0.00 0.00 40.50 0 0 0 0 0.00 0.00 0.00 0 0 1236 A992-->A992
A992-->A992


Unidentified Parts
Part GUID Part
AAF53FC1-81AA-48FA-A577-BE109FB3D10E PL0.375
88AF0557-06BB-4EB6-A410-BC1F83B58DDE PL0.75X10
3B72539D-DEE6-404D-9C3E-73ACC9FA1830 PL0.75X10
31DCB31F-65DA-4ECF-91C9-9A2C44B8455F PL0.75X10