B+Op Status: B+Op was disabled
Building Code: AISC-14
Design Type: LRFD
Engineering Units: Imperial
Bolt Catalog: ASTM Imperial
Profile Catalog: ASTM Imperial
Plate Material Grade Catalog: ASTM Imperial
Plate Thickness Catalog: Imperial
Detailing Distances Dimensions: Imperial
Materials: 
Weld E70
Shear Plate A572-GR.50
Angle A36
Bm Web Doubler Plate A572-GR.50
Stabilizer Plate A572-GR.50
End Plate A572-GR.50
Col Moment Plate A572-GR.50
Col Stiffener Plate A572-GR.50
Col Web Doubler Plate A572-GR.50

Summary Reports: Job Standard Summary  |  Job Sample Calcs Report  |  B+Op Comparison Report
Job Preferences Report  |  No Connections Summary  |  No Connections Detailed  |  No Connections Reference Map
 
Shear Plate Reports: Specs  Strengths (Shear Only Connections)  Strengths (Shear & Axial Connections)  Welds  Doublers
Single Angle Reports:  Specs  Strengths (Shear & Axial)  Welds  Doublers
Double Angle Reports:  Support Side Specs  Beam Side Specs  Strengths (Shear & Axial)  Welds  Doublers
End Plate Reports:  Specs  Strengths (Shear & Axial)  Welds
Moment Reports:  Specs  Support Strengths  Support Reinforcement Strengths  Moment Plate Strengths  Welds
Moment Group Reports:  Doubler Plate Specs  Doubler Plate Welds  Stiffener / Moment Plate Specs  Stiffener / Moment Plate Welds

Identified Connections
Connection Status Support & Beam GUIDs Filler Beam Girder/Col Subgroup Type Connecting Area Perimeter Part Slope Skew Vertical Offset Horizontal Offset Span Vertical Shear Horizontal Shear Axial Compression Axial Tension DL Gravity Moment LL Gravity Moment Lateral Moment (xx) Moment (yy) Torsion Work Point Z (Elevation)
Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
D264C0DB-971B-4C14-9B9E-4B0CA73C2380
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 33 0 0 0 0.00 0.00 0.00 0 0 708.625
Inadequate space to connect beams framing to the same side of the support. 513CA458-BCA5-4485-887A-7CCBE0A15528
82DA1330-DBB9-43D6-BAF9-FA55DAF5A601
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 726.75
Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
F697EB99-F1D5-42C9-8713-4D01B659EB10
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 546.625
Inadequate space to connect beams framing to the same side of the support. C467921C-493F-45AD-9E62-A315333FD341
FE9B06A8-5CE8-4ACA-9F29-DC4D84366934
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 564.75
Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
9B0E2C9C-B8E5-4C33-9A68-FE2D9B405D16
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 33 0 0 0 0.00 0.00 0.00 0 0 384.625
Inadequate space to connect beams framing to the same side of the support. 821521D9-8B35-497D-A9B2-11DDBF27AA6F
0C608DA6-3310-40FE-BE53-8DAA2337F78A
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 402.75
Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
B0AE673A-D765-41E0-B4A7-F04A88E8C666
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1356.63
Inadequate space to connect beams framing to the same side of the support. 5EC7EC86-9DDE-43A1-91E4-AE09322B7360
73D4FE4C-6B7E-4FC6-9DD3-1EB6DBCDA25A
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1374.75
Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
01870393-240A-4DCE-9A6D-29C866AA14B7
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1518.63
Inadequate space to connect beams framing to the same side of the support. CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
BF09E36F-D0F0-470A-9955-FFF6BD961210
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1536.75
Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
90B14FFD-85F1-4AC9-AE6C-3E8A546AF3A0
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 870.625
Inadequate space to connect beams framing to the same side of the support. 3EDF3563-93EB-42E2-94D2-048DCEFD098A
C72C2A0A-A691-4CC3-85A7-2EBB25E257A9
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 888.75
Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
F9D1D7F0-91A1-4BD2-8B22-567189A43574
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1032.63
Inadequate space to connect beams framing to the same side of the support. EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
B8C2A21D-70E3-497D-AAA5-49E1CACEDA37
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1050.75
Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
AEB73A92-1F8B-41BB-8C02-EA917305324B
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1194.63
Inadequate space to connect beams framing to the same side of the support. 30D80433-5F2B-43A3-BB33-539C9C1B3012
7F0E6AD2-5981-48AB-AEFC-FD4C32B58530
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1212.75
Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
3445C3F2-BACD-4EAD-88E7-ED1AF860A921
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 1680.63
Inadequate space to connect beams framing to the same side of the support. E95CC985-766A-40B5-843A-91C246B9ECEA
A8B3F9E3-164F-4779-A235-529A1E135F45
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 1698.75
Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
0D9E4A9E-DE97-4127-BCCB-8F4F5C561506
W12X14 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 -11.75 0.00 10.27 40 0 0 0 0.00 0.00 0.00 0 0 222.625
Inadequate space to connect beams framing to the same side of the support. D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
D0D59AF9-4838-4A07-9619-2715740F8C0C
W30X116 W24X55 BEAM_TO_BEAM NONE 0 0.00 -90.00 6.38 0.00 44.88 84.0541 0 0 0 0.00 0.00 0.00 0 0 240.75
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA2C79DF-4464-4828-8B5A-DF0586C652DD
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1032.63
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DA9B453D-CE7A-4935-AA25-C32EB8CCB2C4
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1036.5
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
EB2FB9FA-F7A9-46E9-800E-FE6F056491B9
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1044.38
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
57578118-5DED-465C-8EB1-C8D1958EA3E8
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1050.63
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
10182BFB-3F0E-402E-B372-A4CB2E5E1742
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 27 0 0 0 0.00 0.00 0.00 0 0 708.625
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
F4EE37B9-E741-4D36-B39B-06EF520F33D4
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 712.5
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
513CA458-BCA5-4485-887A-7CCBE0A15528
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 720.375
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
96E8B22E-A55B-4E49-B1AE-93DBB8E7B139
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 726.625
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
DB888ED2-2EFB-4594-B51A-BE66A8A25278
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 870.625
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
206F21FD-019F-4E90-B100-F1A4020AF3B3
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 874.5
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3EDF3563-93EB-42E2-94D2-048DCEFD098A
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 882.375
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
ACEC7EE8-E7E7-4F4D-8481-ED07320975EE
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 888.625
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
B61368C3-F1F0-4877-8A2F-9C1560903460
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1680.63
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
D4CF178C-8391-4B21-849E-53C3C2811D0F
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1684.5
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
E95CC985-766A-40B5-843A-91C246B9ECEA
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1692.38
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
68374965-673C-4F2A-B6E8-1E2A35BB5D67
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1698.63
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
3920436F-0D69-42D9-92ED-5EB2A1854AF2
W12X14 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1194.63
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
B11ABEDF-B74E-47B4-A3D2-00EB87ED4F40
W16X26 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 1198.5
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
30D80433-5F2B-43A3-BB33-539C9C1B3012
W24X55 W14X90 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1206.38
Inadequate space to connect beams framing to the same side of the support. C18CECA7-786E-438A-90F1-3E9D531A96FE
C4C677BF-01CF-40B6-AA60-FD5CB49EA76B
W30X108 W14X90 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1212.63
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9FF912D-F57B-4621-AD56-820FFDFF41EB
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1356.63
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
265B3CBE-072B-4CE2-9EE1-FC28AAE074F9
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1360.5
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
5EC7EC86-9DDE-43A1-91E4-AE09322B7360
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1368.38
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C7213124-48AA-40CB-B8DD-61160DF07882
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1374.63
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
C9B41AB5-9928-4556-B238-0DB97FCBEDA7
W12X14 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 1518.63
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
DB2DCC2D-0928-4A7B-9657-F26B2C0F0C17
W16X26 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 1522.5
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
CE8AE691-F9D6-49DB-B38B-A3263CC63E1E
W24X55 W14X68 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 1530.38
Inadequate space to connect beams framing to the same side of the support. C284BE98-8C8B-4F63-A459-B4C32103553D
9ED7B62F-8CF2-4A54-821D-1C08FC0622BB
W30X108 W14X68 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 1536.63
Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E314A306-7243-4D8E-B2B6-AAE799C6E321
W12X14 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 222.625
Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
E79D86EE-97AC-4B9A-B282-A608B7763E08
W16X26 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 226.5
Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D2C6A654-0C2F-47A2-B246-BE6C1D66FB5D
W24X55 W14X132 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 234.375
Inadequate space to connect beams framing to the same side of the support. ECCA29B2-B9EC-4C30-841D-42B7C64F2EFC
D5B94786-A91C-4967-982E-220EF3465CED
W30X108 W14X132 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 240.625
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
B97C2FC4-AEBC-4586-BFD2-2838ABD4CE22
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 33 0 0 0 0.00 0.00 0.00 0 0 546.625
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
E9A564FA-1924-4FF2-911F-C01F6D2D7BFA
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 33 0 0 0 0.00 0.00 0.00 0 0 550.5
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
C467921C-493F-45AD-9E62-A315333FD341
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 558.375
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
2DFE2DB3-B007-4F74-9E03-FAD3F1C597E8
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 564.625
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
973C2E2B-E36F-42DC-B124-77DA0D022762
W12X14 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.01 0.00 0.00 10.52 27 0 0 0 0.00 0.00 0.00 0 0 384.625
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
C2667425-7FE3-43DB-B0B6-1D3A1E4ED965
W16X26 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.03 0.00 0.00 9.75 25 0 0 0 0.00 0.00 0.00 0 0 388.5
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
821521D9-8B35-497D-A9B2-11DDBF27AA6F
W24X55 W14X109 BEAM_TO_COLUMN WEB 0 0.00 -83.01 0.00 0.00 20.00 66.8661 0 0 0 0.00 0.00 0.00 0 0 396.375
Inadequate space to connect beams framing to the same side of the support. A4BCA449-3F74-4868-92C4-37314EE32E81
CE568E02-A0A7-472A-8E17-8219D9C19567
W30X108 W14X109 BEAM_TO_COLUMN FLANGE 0 0.00 -83.00 0.00 0.00 44.92 76.8652 0 0 0 0.00 0.00 0.00 0 0 402.625